메뉴 건너뛰기




Volumn 25, Issue 11, 2002, Pages 1599-1604

Automatic discrimination between supraventricular and ventricular tachycardia using a multilayer perceptron in implantable cardioverter defibrillators

Author keywords

Defibrillator; Electrogram; Neural network; Ventricular tachycardia

Indexed keywords

ACCURACY; ARTICLE; ARTIFICIAL NEURAL NETWORK; AUTOMATION; CLINICAL ARTICLE; CONTROLLED STUDY; DEFIBRILLATOR; DEVICE; ELECTROCARDIOGRAM; ELECTROGRAPHY; HEART ELECTROPHYSIOLOGY; HEART VENTRICLE TACHYCARDIA; HUMAN; IMPLANTATION; INTERMETHOD COMPARISON; PERFORMANCE; SIGNAL PROCESSING; SUPRAVENTRICULAR TACHYCARDIA; VALIDATION PROCESS; ALGORITHM; DIFFERENTIAL DIAGNOSIS; EQUIPMENT DESIGN; FEMALE; MALE; MIDDLE AGED; REPRODUCIBILITY;

EID: 1842852792     PISSN: 01478389     EISSN: None     Source Type: Journal    
DOI: 10.1046/j.1460-9592.2002.01599.x     Document Type: Article
Times cited : (5)

References (14)
  • 1
    • 0030107497 scopus 로고    scopus 로고
    • Detection algorithms in implantable cardioverter defibrillators
    • Jenkins JM, Caswell SA. Detection algorithms in implantable cardioverter defibrillators. Proc of the IEEE 1996; 84:428-444.
    • (1996) Proc of the IEEE , vol.84 , pp. 428-444
    • Jenkins, J.M.1    Caswell, S.A.2
  • 2
    • 0031903380 scopus 로고    scopus 로고
    • Prospective evaluation of new and old criteria to discriminate between supraventricular and ventricular tachycardia in implantable defibrillators
    • Barold HS, Newby KH, Tomassoni G, et al. Prospective evaluation of new and old criteria to discriminate between supraventricular and ventricular tachycardia in implantable defibrillators. PACE 1998; 21:1347-1355.
    • (1998) PACE , vol.21 , pp. 1347-1355
    • Barold, H.S.1    Newby, K.H.2    Tomassoni, G.3
  • 3
    • 0033779165 scopus 로고    scopus 로고
    • Dual chamber arrhythmia detection in the implantable cardioverter defibrillator
    • Dijkman B, Wellens HJJ. Dual chamber arrhythmia detection in the implantable cardioverter defibrillator. J Cardiovasc Electrophysiol 2000; 11:1105-1115.
    • (2000) J Cardiovasc Electrophysiol , vol.11 , pp. 1105-1115
    • Dijkman, B.1    Wellens, H.J.J.2
  • 4
    • 0033761868 scopus 로고    scopus 로고
    • Diagnosis and therapy of atrial tachyarrhythmias in the dual chamber implantable cardioverter defibrillator
    • Dijkman B, Wellens HJJ. Diagnosis and therapy of atrial tachyarrhythmias in the dual chamber implantable cardioverter defibrillator. J Cardiovasc Electrophysiol 2000; 11:1196-1205.
    • (2000) J Cardiovasc Electrophysiol , vol.11 , pp. 1196-1205
    • Dijkman, B.1    Wellens, H.J.J.2
  • 5
    • 0343775801 scopus 로고    scopus 로고
    • Detection of atrial fibrillation and flutter by a dual-chamber implantable cardioverter-defibrillator
    • Swerdlow CD, Schsls W, Dijkman B, et al. Detection of atrial fibrillation and flutter by a dual-chamber implantable cardioverter-defibrillator. Circulation 2000; 101:878-885.
    • (2000) Circulation , vol.101 , pp. 878-885
    • Swerdlow, C.D.1    Schsls, W.2    Dijkman, B.3
  • 6
    • 0030709197 scopus 로고    scopus 로고
    • Analysis of the intraventricular electrogram for differentiation of distinct monomorphic ventricular arrhythmias
    • Stevenson SA, Jenkins JM, DiCarlo LA. Analysis of the intraventricular electrogram for differentiation of distinct monomorphic ventricular arrhythmias. PACE 1997; 20:2730-2738.
    • (1997) PACE , vol.20 , pp. 2730-2738
    • Stevenson, S.A.1    Jenkins, J.M.2    DiCarlo, L.A.3
  • 7
    • 0031857916 scopus 로고    scopus 로고
    • Intracardiac QRS electrogram width. An arrhythmia detection feature for implantable cardioverter defibrillator. Exercise induced variation as a base for device programming
    • Klingenheben T, Sticherling C, Skupin M, et al. Intracardiac QRS electrogram width. An arrhythmia detection feature for implantable cardioverter defibrillator. Exercise induced variation as a base for device programming. PACE 1998; 8:1609-1617.
    • (1998) PACE , vol.8 , pp. 1609-1617
    • Klingenheben, T.1    Sticherling, C.2    Skupin, M.3
  • 8
    • 0027408765 scopus 로고
    • Implantable cardioverter defibrillator electrogram recognition with a multilayer perceptron
    • Farrugia S, Nickolls P. Implantable cardioverter defibrillator electrogram recognition with a multilayer perceptron. PACE 1993; 16:228-234.
    • (1993) PACE , vol.16 , pp. 228-234
    • Farrugia, S.1    Nickolls, P.2
  • 9
    • 0026757734 scopus 로고
    • MATIC - An intracardiac tachycardia classification system
    • Leong PHW, Jabri MA. MATIC - An intracardiac tachycardia classification system. PACE 1992; 15:1317-1331.
    • (1992) PACE , vol.15 , pp. 1317-1331
    • Leong, P.H.W.1    Jabri, M.A.2
  • 10
    • 0032957206 scopus 로고    scopus 로고
    • Real-time discrimination of ventricular tachyarrhythmia with fourier-transform neural network
    • Minami K, Nakajima H, Toyoshima T. Real-time discrimination of ventricular tachyarrhythmia with fourier-transform neural network. IEEE Trans Biomed Eng 1999; 46:179-185.
    • (1999) IEEE Trans Biomed Eng , vol.46 , pp. 179-185
    • Minami, K.1    Nakajima, H.2    Toyoshima, T.3
  • 11
    • 0035936534 scopus 로고    scopus 로고
    • Critical analysis of dual-chamber implantable cardioverter-defibrillator arrhythmia detection. Results and technical considerations
    • Wilkoff BL, Kühlkamp V, Volosin K, et al. Critical analysis of dual-chamber implantable cardioverter-defibrillator arrhythmia detection. Results and technical considerations. Circulation 2001; 103:381-386.
    • (2001) Circulation , vol.103 , pp. 381-386
    • Wilkoff, B.L.1    Kühlkamp, V.2    Volosin, K.3
  • 12
    • 0030152326 scopus 로고    scopus 로고
    • Computation of time-specified tolerance intervals for ambulatorily monitored blood pressure
    • Hermida RC, Fernández JR. Computation of time-specified tolerance intervals for ambulatorily monitored blood pressure. Biomed Instrum Technol 1996; 30:256-266.
    • (1996) Biomed Instrum Technol , vol.30 , pp. 256-266
    • Hermida, R.C.1    Fernández, J.R.2
  • 13
    • 0030752341 scopus 로고    scopus 로고
    • Computation of time-specified tolerance intervals for hybrid time series with nonequidistant sampling, illustrated for plasma growth hormone
    • Hermida RC, Fernández JR, Alonso I, et al. Computation of time-specified tolerance intervals for hybrid time series with nonequidistant sampling, illustrated for plasma growth hormone. Chronobiol Int 1997; 14:409-425.
    • (1997) Chronobiol Int , vol.14 , pp. 409-425
    • Hermida, R.C.1    Fernández, J.R.2    Alonso, I.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.