메뉴 건너뛰기




Volumn 7, Issue 2, 2004, Pages 113-125

An Investigation of the Effect of Modifying Stimulation Profile Shape on the Loading Response Phase of Gait, during FES-Corrected Drop Foot: Stimulation Profile and Loading Response

Author keywords

Drop foot gait; Electrical stimulation; Hemiplegic gait; Orthotic devices

Indexed keywords

ARTICLE; CASE REPORT; ELECTROMYOGRAPHY; ELECTROSTIMULATION THERAPY; GAIT; GONIOMETRY; HEMIPLEGIA; HUMAN; KINEMATICS; MALE; ORTHOTICS; PERONEUS NERVE PARALYSIS; TORQUE;

EID: 1842782798     PISSN: 10947159     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1094-7159.2004.04015.x     Document Type: Article
Times cited : (11)

References (25)
  • 1
    • 0036991511 scopus 로고    scopus 로고
    • A review of portable FES-based neural orthoses for the correction of drop foot
    • Lyons GM, Sinkjaer T, Burridge J, Wilcox DJ. A review of portable FES-based neural orthoses for the correction of drop foot. IEEE Trans Neur Sys Reh 2002;10:260-279.
    • (2002) IEEE Trans Neur Sys Reh , vol.10 , pp. 260-279
    • Lyons, G.M.1    Sinkjaer, T.2    Burridge, J.3    Wilcox, D.J.4
  • 2
    • 73049136842 scopus 로고
    • Functional electrotherapy, stimulation of the peroneal nerve synchronized with the swing phase of the gait of hemiplegic patients
    • Liberson WT, Holmquest HJ, Scott D, Dow M. Functional electrotherapy, stimulation of the peroneal nerve synchronized with the swing phase of the gait of hemiplegic patients. Arch Phys Med Rehab 1961;42:22-205.
    • (1961) Arch Phys Med Rehab , vol.42 , pp. 22-205
    • Liberson, W.T.1    Holmquest, H.J.2    Scott, D.3    Dow, M.4
  • 3
    • 0030703706 scopus 로고    scopus 로고
    • The effects of common peroneal stimulation on the effort and speed of walking: A randomised controlled trial with chronic hemiplegic patients
    • Burridge JH, Taylor PN, Hagan SA, Wood DE, Swain ID. The effects of common peroneal stimulation on the effort and speed of walking: a randomised controlled trial with chronic hemiplegic patients. Clin Rehab 1997;11:201-210.
    • (1997) Clin Rehab , vol.11 , pp. 201-210
    • Burridge, J.H.1    Taylor, P.N.2    Hagan, S.A.3    Wood, D.E.4    Swain, I.D.5
  • 4
    • 0018676840 scopus 로고
    • Clinical experience of electronic peroneal stimulators in hemiparetic 50 patients
    • Merletti R, Andina A, Galante M, Furlan I. Clinical experience of electronic peroneal stimulators in hemiparetic 50 patients. Scan J Rehab Med 1979;11:111-121.
    • (1979) Scan J Rehab Med , vol.11 , pp. 111-121
    • Merletti, R.1    Andina, A.2    Galante, M.3    Furlan, I.4
  • 9
    • 0023052723 scopus 로고
    • Videnskab og Praksis-Original Meddelelse-Klinisk erfaring med en ny dropfodstimulator - Clinical Experience with new peroneal stimulator
    • Pedersen E, Petersen T, Hansen C, Klemar B. Videnskab og Praksis-Original Meddelelse-Klinisk erfaring med en ny dropfodstimulator - Clinical Experience with new peroneal stimulator. Ugeskrift for Laeger 1986;148(21):1272-1275.
    • (1986) Ugeskrift for Laeger , vol.148 , Issue.21 , pp. 1272-1275
    • Pedersen, E.1    Petersen, T.2    Hansen, C.3    Klemar, B.4
  • 10
    • 1842741677 scopus 로고    scopus 로고
    • Salisbury: Department of Medical Physics and Biomedical Engineering, Salisbury District Hospital
    • Salisbury Health Care. The Odstock Dropped Foot Stimulator ODFS III Full Clinician Instruction Manual. Salisbury: Department of Medical Physics and Biomedical Engineering, 1998, Salisbury District Hospital.
    • (1998) The Odstock Dropped Foot Stimulator ODFS III Full Clinician Instruction Manual
  • 11
    • 0017325539 scopus 로고
    • Effect of gradually modulated electrical stimulation on the plasticity of artificially evoked movements
    • Stanic U, Trnkoczy A, Acimovic R, Gros N. Effect of gradually modulated electrical stimulation on the plasticity of artificially evoked movements. Med Biol Eng Comput 1977;15:62-66.
    • (1977) Med Biol Eng Comput , vol.15 , pp. 62-66
    • Stanic, U.1    Trnkoczy, A.2    Acimovic, R.3    Gros, N.4
  • 12
    • 0013274353 scopus 로고    scopus 로고
    • Evaluation of a drop foot stimulator FES intensity envelope matched to tibialis anterior muscle activity during walking
    • Lyons GM, Wilcox DJ, Lyons DJ, Hilton D. Evaluation of a drop foot stimulator FES intensity envelope matched to tibialis anterior muscle activity during walking. In: Proceedings of the 5th Annual IFESS Conference. 2000;448-451.
    • (2000) Proceedings of the 5th Annual IFESS Conference , pp. 448-451
    • Lyons, G.M.1    Wilcox, D.J.2    Lyons, D.J.3    Hilton, D.4
  • 13
    • 0013220673 scopus 로고
    • Electrical stimulation of paretic leg muscles in man, allowing feedback controlled movements to be generated from the wrist
    • Prochazka A, Wiles CM. Electrical stimulation of paretic leg muscles in man, allowing feedback controlled movements to be generated from the wrist. J Physiol 1983;343:20P-21P.
    • (1983) J Physiol , vol.343
    • Prochazka, A.1    Wiles, C.M.2
  • 14
    • 0002328195 scopus 로고    scopus 로고
    • Correction of drop foot using a fuzzy logic controlled miniature stimulator
    • Mourselas N, Granat MH. Correction of drop foot using a fuzzy logic controlled miniature stimulator. In: Proc. 5th Annual IFESS Conference 2000;456-457.
    • (2000) Proc 5th Annual IFESS Conference , pp. 456-457
    • Mourselas, N.1    Granat, M.H.2
  • 15
    • 0034960558 scopus 로고    scopus 로고
    • The development of a closed-loop controlled functional electrical stimulation (FES) in gait training
    • Chen Y-L, Li Y-C, Kuo T-S, Lai J-S. The development of a closed-loop controlled functional electrical stimulation (FES) in gait training. J Med Eng Technol 2001;25:41-48.
    • (2001) J Med Eng Technol , vol.25 , pp. 41-48
    • Chen, Y.-L.1    Li, Y.-C.2    Kuo, T.-S.3    Lai, J.-S.4
  • 19
    • 0345099656 scopus 로고    scopus 로고
    • Modified implanted drop foot stimulator system with graphical user interface for customised stimulation pulse-width profiles
    • O'Halloran T, Haugland M, Lyons GM, Sinkjaer T. Modified implanted drop foot stimulator system with graphical user interface for customised stimulation pulse-width profiles. Med Biol Eng Comput 2003;41:6.
    • (2003) Med Biol Eng Comput , vol.41 , pp. 6
    • O'Halloran, T.1    Haugland, M.2    Lyons, G.M.3    Sinkjaer, T.4
  • 20
    • 0023695436 scopus 로고
    • Muscle stiffness in human ankle dorsiflexors: Intrinsic and reflex components
    • Sinkjaer T, Toft E, Andreassen S, Hornemann BC. Muscle stiffness in human ankle dorsiflexors: intrinsic and reflex components. J Neurophysiol 1988;60:1110-1121.
    • (1988) J Neurophysiol , vol.60 , pp. 1110-1121
    • Sinkjaer, T.1    Toft, E.2    Andreassen, S.3    Hornemann, B.C.4
  • 22
    • 0021251846 scopus 로고
    • Pathologic gait diagnosis with computer-averaged electromyographic profiles
    • Winter DA. Pathologic gait diagnosis with computer-averaged electromyographic profiles. Arch Phys Med Rehab 1984;65:393-398.
    • (1984) Arch Phys Med Rehab , vol.65 , pp. 393-398
    • Winter, D.A.1
  • 23
    • 0021163138 scopus 로고
    • Electromyographic amplitude normalization methods: Improving their sensitivity as diagnostic tools in gait analysis
    • Yang JF, Winter DA. Electromyographic amplitude normalization methods: improving their sensitivity as diagnostic tools in gait analysis. Arch Phys Med Rehab 1984;56:517-521.
    • (1984) Arch Phys Med Rehab , vol.56 , pp. 517-521
    • Yang, J.F.1    Winter, D.A.2
  • 24
    • 0032820270 scopus 로고    scopus 로고
    • Temporal parameters and patterns of the foot roll over during walking: Normative data for healthy adults
    • Blanc Y, Balmer C, Landis T, Vingerhoets F. Temporal parameters and patterns of the foot roll over during walking: normative data for healthy adults. Gait Posture 1999;10:97-108.
    • (1999) Gait Posture , vol.10 , pp. 97-108
    • Blanc, Y.1    Balmer, C.2    Landis, T.3    Vingerhoets, F.4
  • 25
    • 0034283310 scopus 로고    scopus 로고
    • The relationship between electrical stimulus and joint torque. Dynamic model
    • Ferrarin M, Pedotti A. The relationship between electrical stimulus and joint torque. Dynamic model. IEEE Trans Rebabil Eng 2000;8:3.
    • (2000) IEEE Trans Rebabil Eng , vol.8 , pp. 3
    • Ferrarin, M.1    Pedotti, A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.