2
-
-
73049136842
-
Functional electrotherapy: Stimulation of the peroneal nerve synchronized with the swing phase of the gait of hemiplegic patients
-
Liberson WT, Holmquest HJ, Scott D, Dow M. Functional electrotherapy: stimulation of the peroneal nerve synchronized with the swing phase of the gait of hemiplegic patients. Arch Phys Med Rehabil 1961;42:101-5.
-
(1961)
Arch Phys Med Rehabil
, vol.42
, pp. 101-105
-
-
Liberson, W.T.1
Holmquest, H.J.2
Scott, D.3
Dow, M.4
-
3
-
-
0016615554
-
Quantitive gait evaluation of hemiplegic patients using electrical stimulation orthoses
-
Kljajic M, Bajd T, Stanic U. Quantitive gait evaluation of hemiplegic patients using electrical stimulation orthoses. IEEE Trans Biomed Eng 1975;22:438-41.
-
(1975)
IEEE Trans Biomed Eng
, vol.22
, pp. 438-441
-
-
Kljajic, M.1
Bajd, T.2
Stanic, U.3
-
4
-
-
0027484389
-
Enhancement of hemplegic patient rehabilitation by means of functional electrical stimulation
-
Kralj A, Acimovic R, Stanic U. Enhancement of hemplegic patient rehabilitation by means of functional electrical stimulation. Prosthet Orthot Int 1993;17:104-7.
-
(1993)
Prosthet Orthot Int
, vol.17
, pp. 104-107
-
-
Kralj, A.1
Acimovic, R.2
Stanic, U.3
-
5
-
-
12644262646
-
Peripheral nerve stimulation, superficial and implanted
-
Fields WS, Leavitt, editors. New York: Intercontinental Medical Book Corporation
-
McNeal DR. Peripheral nerve stimulation, superficial and implanted. In: Fields WS, Leavitt, editors. Neural organization and its relevance to prosthetics. New York: Intercontinental Medical Book Corporation, 1973:77-99.
-
(1973)
Neural Organization and Its Relevance to Prosthetics
, pp. 77-99
-
-
McNeal, D.R.1
-
6
-
-
0026926317
-
Application of a programmable dual-channel adaptive electrical stimulation system for the control and analysis of gait
-
Malezic M, Bogataj U, Gros N, Decman I, Vrtacnik P, Kljajic M, et al. Application of a programmable dual-channel adaptive electrical stimulation system for the control and analysis of gait. J Rehab Res Dev 1992;29:41-53.
-
(1992)
J Rehab Res Dev
, vol.29
, pp. 41-53
-
-
Malezic, M.1
Bogataj, U.2
Gros, N.3
Decman, I.4
Vrtacnik, P.5
Kljajic, M.6
-
7
-
-
0018095060
-
Multichannel electrical stimulation for correction of hemiplegic gait
-
Stanic U, Acimovic-Janezic R, Gros N, Trnkoczy A, Bajd T, Kljajic M. Multichannel electrical stimulation for correction of hemiplegic gait. Scand J Rehab Med 1978;10:75-92.
-
(1978)
Scand J Rehab Med
, vol.10
, pp. 75-92
-
-
Stanic, U.1
Acimovic-Janezic, R.2
Gros, N.3
Trnkoczy, A.4
Bajd, T.5
Kljajic, M.6
-
8
-
-
0026664807
-
Gait evaluation in hemiparetic patients using subcutaneous peroneal electrical stimulation
-
Kljajic M, Malezic M, Acimovic R, Vavken E, Stanic U, Pangrsic B, et al. Gait evaluation in hemiparetic patients using subcutaneous peroneal electrical stimulation. Scand J Rehab Med 1992;24:121-6.
-
(1992)
Scand J Rehab Med
, vol.24
, pp. 121-126
-
-
Kljajic, M.1
Malezic, M.2
Acimovic, R.3
Vavken, E.4
Stanic, U.5
Pangrsic, B.6
-
9
-
-
0016615554
-
Quantitive gait evaluation of hemiplegic patients using electrical stimulation orthoses
-
Kljajic M, Bajd T, Stanic U. Quantitive gait evaluation of hemiplegic patients using electrical stimulation orthoses. IEEE Trans Biomed Eng 1975;22:438-41.
-
(1975)
IEEE Trans Biomed Eng
, vol.22
, pp. 438-441
-
-
Kljajic, M.1
Bajd, T.2
Stanic, U.3
-
10
-
-
0018676840
-
Clinical experience of electronic peroneal stimulators in 50 hemiparetic patients
-
Merletti R, Andina A, Galante M, Furlan I. Clinical experience of electronic peroneal stimulators in 50 hemiparetic patients. Scand J Rehab Med 1979;11:111-21.
-
(1979)
Scand J Rehab Med
, vol.11
, pp. 111-121
-
-
Merletti, R.1
Andina, A.2
Galante, M.3
Furlan, I.4
-
11
-
-
0018347130
-
Outcome of comprehensive medical rehabilitation: Measurement by PULSES profile and the Barthel Index
-
Granger CV, Albrecht GL, Hamilton BB. Outcome of comprehensive medical rehabilitation: measurement by PULSES profile and the Barthel Index. Arch Phys Med Rehabil 1979;60:145-54.
-
(1979)
Arch Phys Med Rehabil
, vol.60
, pp. 145-154
-
-
Granger, C.V.1
Albrecht, G.L.2
Hamilton, B.B.3
-
12
-
-
0028304371
-
Retest reliability of the temporal and distance characteristics of hemiplegic gait using a footswitch system
-
Hill KD, Goldie PA, Baker PA, Greenwood KM. Retest reliability of the temporal and distance characteristics of hemiplegic gait using a footswitch system. Arch Phys Med Rehabil 1994;75:577-83.
-
(1994)
Arch Phys Med Rehabil
, vol.75
, pp. 577-583
-
-
Hill, K.D.1
Goldie, P.A.2
Baker, P.A.3
Greenwood, K.M.4
-
13
-
-
0029329221
-
A body-worn gait analysis system for evaluating hemiplegic gait
-
Granat MH, Maxwell DM, Bosch CJ, Ferguson ACB, Lees KR, Barbenel JC. A body-worn gait analysis system for evaluating hemiplegic gait. Med Eng Physics 1995;17:390-4.
-
(1995)
Med Eng Physics
, vol.17
, pp. 390-394
-
-
Granat, M.H.1
Maxwell, D.M.2
Bosch, C.J.3
Ferguson, A.C.B.4
Lees, K.R.5
Barbenel, J.C.6
-
14
-
-
0025739901
-
Classification and natural history of clinically identifiable subtypes of cerebral infarction
-
Bamford J, Sandercock P, Dennis M, Burn J, Warlow C. Classification and natural history of clinically identifiable subtypes of cerebral infarction, Lancet 1991;337:1521-6.
-
(1991)
Lancet
, vol.337
, pp. 1521-1526
-
-
Bamford, J.1
Sandercock, P.2
Dennis, M.3
Burn, J.4
Warlow, C.5
-
15
-
-
0023620739
-
Therapeutic effects of multisite electrics stimulation in motor disabled patients
-
Malezic M, Kljajic M, AcimovicJanezic, Gros N, Krajnik J, Stanic U. Therapeutic effects of multisite electrics stimulation in motor disabled patients. Arch Phys Med Rehabil 1987;68:553-60.
-
(1987)
Arch Phys Med Rehabil
, vol.68
, pp. 553-560
-
-
Malezic, M.1
Kljajic, M.2
AcimovicJanezic3
Gros, N.4
Krajnik, J.5
Stanic, U.6
-
16
-
-
0028392638
-
Implantable stimulator for selective stimulation of the common peroneal nerve: A preliminary report
-
Rozman J, AcimovicJanezic R, Tekavcic I, Kljajic M, Trlep M. Implantable stimulator for selective stimulation of the common peroneal nerve: A preliminary report. J Med Eng Tech 1994;18:47-53.
-
(1994)
J Med Eng Tech
, vol.18
, pp. 47-53
-
-
Rozman, J.1
Acimovicjanezic, R.2
Tekavcic, I.3
Kljajic, M.4
Trlep, M.5
-
17
-
-
0025661988
-
Automatic stance-swing phase detection from the accelerometer data for peroneal nerve stimulation
-
Wllemsen ATM, Bloemhof F, Boom HBK. Automatic stance-swing phase detection from the accelerometer data for peroneal nerve stimulation. IEEE Trans Biomed Eng 1990;37:1201-8.
-
(1990)
IEEE Trans Biomed Eng
, vol.37
, pp. 1201-1208
-
-
Wllemsen, A.T.M.1
Bloemhof, F.2
Boom, H.B.K.3
|