메뉴 건너뛰기




Volumn 5287, Issue , 2002, Pages 52-61

Biocompatible metallic stent for medical therapy

Author keywords

Electrical discharge machining; Etching; Laser cutting; Stent; Surface modification

Indexed keywords

BIOCOMPATIBILITY; CARDIOVASCULAR SYSTEM; DISEASES; ELECTRIC DISCHARGE MACHINING; ETCHING; HEAT AFFECTED ZONE; LASER PULSES; METALS; NEODYMIUM LASERS; OPACITY; SURFACE ROUGHNESS; SURFACE TREATMENT;

EID: 1842608430     PISSN: 0277786X     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (6)

References (15)
  • 1
    • 0031148733 scopus 로고    scopus 로고
    • Alteration of hemodynamics in aneurysm models by stenting: Influence of stent porosity
    • Baruch B. Lieber, Alfred P. Stancampiano and Ajay K. Wakhloo (1997). Alteration of hemodynamics in aneurysm models by stenting: Influence of stent porosity. Annals of Biomedical Engineering 460-469.
    • (1997) Annals of Biomedical Engineering , pp. 460-469
    • Lieber, B.B.1    Stancampiano, A.P.2    Wakhloo, A.K.3
  • 2
    • 1342291434 scopus 로고    scopus 로고
    • Buddy D. Ratner and Allan S. Hoffman, Frederick J. Schoen and Jack E. Lemons (eds.); New York: Academic Press
    • Buddy D. Ratner and Allan S. Hoffman, Frederick J. Schoen and Jack E. Lemons (eds.): Biomaterial Science. Chapter: Cardiovascular applications. New York: Academic Press, pp. 289.
    • Biomaterial Science. Chapter: Cardiovascular Applications , pp. 289
  • 3
    • 0033621145 scopus 로고    scopus 로고
    • Stent-versus-stent equivalency trials
    • E. R. Edelman and Campbell Rogers (1999). Stent-versus-stent equivalency trials. Circulation 896-898.
    • (1999) Circulation , pp. 896-898
    • Edelman, E.R.1    Rogers, C.2
  • 4
    • 0036431124 scopus 로고    scopus 로고
    • An overview of superelastic stent design
    • T. W. Duerig and A. R. Pelton (2002). An overview of superelastic stent design. Material Science Forum Vol. 394-395, pp.29-32.
    • (2002) Material Science Forum , vol.394-395 , pp. 29-32
    • Duerig, T.W.1    Pelton, A.R.2
  • 12
    • 0030151357 scopus 로고    scopus 로고
    • Improvement of stenting therapy with a silicon carbide coated tantalum stent
    • M. Amon, A. Bolz and M. Schaldach (1996). Improvement of stenting therapy with a silicon Carbide coated tantalum stent. Jour. of Material Sci. in Medicine 273-278.
    • (1996) Jour. of Material Sci. in Medicine , pp. 273-278
    • Amon, M.1    Bolz, A.2    Schaldach, M.3
  • 14
    • 1842568003 scopus 로고    scopus 로고
    • Gerhard Bluemachen, Eds.; Pub.: Kohlhammer, Koeln Germany
    • Gerhard Bluemachen, Eds. (1996). Herzinfarkt. Pub.: Kohlhammer, Koeln Germany, pp.136-137.
    • (1996) Herzinfarkt , pp. 136-137
  • 15
    • 0005365737 scopus 로고    scopus 로고
    • Laser precision processing in microtechnology: Part 1 Nd-YAG laser processing
    • Erlangen Germany
    • Y. P. Kathuria (1997). Laser precision processing in microtechnology: Part 1 Nd-YAG laser processing. Proc. Lane'97 pp.267-272 Erlangen Germany.
    • (1997) Proc. Lane'97 , pp. 267-272
    • Kathuria, Y.P.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.