메뉴 건너뛰기




Volumn 19, Issue 1, 1997, Pages 1-18

Reduction of the clutter component in Doppler ultrasound signals based on singular value decomposition: A simulation study

Author keywords

Clutter suppression; Pulsed Doppler; RF domain signal processing; Signal processing; Singular value decomposition (SVD); Ultrasound; Vessel wall filter

Indexed keywords

BLOOD; CLUTTER (INFORMATION THEORY); ECHO SUPPRESSION; FLOW VELOCITY; HEMODYNAMICS; HIGH PASS FILTERS; NON NEWTONIAN FLOW; RADAR CLUTTER; SIGNAL PROCESSING; ULTRASONICS; VELOCITY DISTRIBUTION;

EID: 0030848446     PISSN: 01617346     EISSN: None     Source Type: Journal    
DOI: 10.1177/016173469701900101     Document Type: Article
Times cited : (105)

References (19)
  • 1
    • 0028929004 scopus 로고
    • Biophysical principles of vascular diagnosis
    • Hoeks, A. P. G. and Reneman, R. S., Biophysical principles of vascular diagnosis, J. Clin. Ultrasound 23, 71-79 (1995).
    • (1995) J. Clin. Ultrasound , vol.23 , pp. 71-79
    • Hoeks, A.P.G.1    Reneman, R.S.2
  • 3
    • 0029080883 scopus 로고
    • The effect of echo suppression on the mean velocity estimation range of the RF cross-correlation model estimator
    • Brands, P. J., Hoeks, A. P. G., and Reneman, R. S., The effect of echo suppression on the mean velocity estimation range of the RF cross-correlation model estimator, Ultrasound Med. Biol. 21, 945-959 (1995).
    • (1995) Ultrasound Med. Biol. , vol.21 , pp. 945-959
    • Brands, P.J.1    Hoeks, A.P.G.2    Reneman, R.S.3
  • 4
  • 5
    • 0029151554 scopus 로고
    • Adaptive SVD-based AR model order determination for time-frequency analysis of Doppler ultrasound signals
    • Fort, A., Manfredi, C., and Rocchi, S., Adaptive SVD-based AR model order determination for time-frequency analysis of Doppler ultrasound signals, Ultrasound Med. Biol. 21, 793-805 (1995).
    • (1995) Ultrasound Med. Biol. , vol.21 , pp. 793-805
    • Fort, A.1    Manfredi, C.2    Rocchi, S.3
  • 6
    • 0026220812 scopus 로고
    • On the usefulness of singular value decomposition - ARMA models in Dopier ultrasound
    • Forsberg, F., On the usefulness of singular value decomposition - ARMA models in Dopier ultrasound, IEEE Trans. Ultrason. Ferr. Freq. Control 38, 418-428 (1991).
    • (1991) IEEE Trans. Ultrason. Ferr. Freq. Control , vol.38 , pp. 418-428
    • Forsberg, F.1
  • 7
    • 0026222527 scopus 로고
    • Orthogonal expansions: Their applicability to signal extraction in electrophysiological mapping data
    • Lamothe, R. ,and Stroink, G., Orthogonal expansions: their applicability to signal extraction in electrophysiological mapping data, Medical & Biological Engineering & Computing 29, 522-528 (1991).
    • (1991) Medical & Biological Engineering & Computing , vol.29 , pp. 522-528
    • Lamothe, R.1    Stroink, G.2
  • 8
    • 0025777415 scopus 로고
    • Determination of in vitro simulated blood cell velocity by laser-Doppler with state space methods
    • Ledbetter-Nellepovitz, C. C., Rao, B. D., and Fronek, A., Determination of in vitro simulated blood cell velocity by laser-Doppler with state space methods, Microvascular Research 41, 164-172 (1991).
    • (1991) Microvascular Research , vol.41 , pp. 164-172
    • Ledbetter-Nellepovitz, C.C.1    Rao, B.D.2    Fronek, A.3
  • 15
    • 0343712894 scopus 로고
    • Singular value decomposition in digital signal processing
    • Callaerts, D., Singular value decomposition in digital signal processing, Journal A 32, 11-16 (1991).
    • (1991) Journal A , vol.32 , pp. 11-16
    • Callaerts, D.1
  • 16
    • 0027765520 scopus 로고
    • Comparison of the performance of the RF cross correlation and Doppler autocorrelation technique to estimate the mean velocity of simulated ultrasound signals
    • Hoeks, A. P. G., Arts, T. G. J., Brands, P. J., and Reneman, R. S., Comparison of the performance of the RF cross correlation and Doppler autocorrelation technique to estimate the mean velocity of simulated ultrasound signals, Ultrasound Med. Biol. 19, 727-740 (1993).
    • (1993) Ultrasound Med. Biol. , vol.19 , pp. 727-740
    • Hoeks, A.P.G.1    Arts, T.G.J.2    Brands, P.J.3    Reneman, R.S.4
  • 17
    • 0025329438 scopus 로고
    • Determination of tissue motion velocity by correlation interpolation of pulsed ultrasonic echo signals
    • de Jong, P. G. M., Arts, T., Hoeks, A. P. G., and Reneman, R. S., Determination of tissue motion velocity by correlation interpolation of pulsed ultrasonic echo signals, Ultrasonic Imaging 12, 84-98 (1990).
    • (1990) Ultrasonic Imaging , vol.12 , pp. 84-98
    • De Jong, P.G.M.1    Arts, T.2    Hoeks, A.P.G.3    Reneman, R.S.4
  • 18
    • 0027075115 scopus 로고
    • A comparison method for mean frequency estimators for Doppler ultrasound
    • Brands, P. J. ,and Hoeks, A. P. G., A comparison method for mean frequency estimators for Doppler ultrasound, Ultrasonic Imaging 14, 367-386 (1992).
    • (1992) Ultrasonic Imaging , vol.14 , pp. 367-386
    • Brands, P.J.1    Hoeks, A.P.G.2
  • 19
    • 0024987808 scopus 로고
    • Nonlinear optical effects in oxygen-binding reactions of hemoglobin A0
    • Ownby, D. W. and Stanley, J. G., Nonlinear optical effects in oxygen-binding reactions of hemoglobin A0, Biophysical Chemistry 37, 395-406 (1990).
    • (1990) Biophysical Chemistry , vol.37 , pp. 395-406
    • Ownby, D.W.1    Stanley, J.G.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.