메뉴 건너뛰기




Volumn 33, Issue 4, 2005, Pages 429-443

A comparison of flow field structures of two tri-leaflet polymeric heart valves

Author keywords

Coaptation; Fluid mechanics; Gap channel; Oscillation; Polyurethanes; Vena contracta; Washout

Indexed keywords

COAPTATION; GAP CHANNELS; LASER DOPPLER VELOCIMETRY (LDV); REYNOLDS SHEAR STRESS (RSS); VENA CONTRACTS; WASHOUT;

EID: 18244376582     PISSN: 00906964     EISSN: 15739686     Source Type: Journal    
DOI: 10.1007/s10439-005-2498-z     Document Type: Article
Times cited : (31)

References (30)
  • 1
    • 0029658660 scopus 로고    scopus 로고
    • In vitro function and durability of a polyurethane heart valve: Material considerations
    • Bemacca, G. M., T. G. Mackay, and D. J. Wheatley. In vitro function and durability of a polyurethane heart valve: Material considerations. J. Heart Valve Dis. 5(5):538-542, 1996.
    • (1996) J. Heart Valve Dis. , vol.5 , Issue.5 , pp. 538-542
    • Bemacca, G.M.1    Mackay, T.G.2    Wheatley, D.J.3
  • 3
    • 0036027562 scopus 로고    scopus 로고
    • Hydrodynamic function of polyurethane prosthetic heart valves: Influences of Young's modulus and leaflet thickness
    • Bernacca, G. M., B. O'Connor, D. F. Williams, and D. J. Wheatley. Hydrodynamic function of polyurethane prosthetic heart valves: Influences of Young's modulus and leaflet thickness. Biomaterials 23(1):45-50, 2002.
    • (2002) Biomaterials , vol.23 , Issue.1 , pp. 45-50
    • Bernacca, G.M.1    O'Connor, B.2    Williams, D.F.3    Wheatley, D.J.4
  • 4
    • 0024564191 scopus 로고
    • In vitro comparison of velocity profiles and turbulent shear distal to polyurethane trileaflet and pericardial prosthetic valves
    • Chandran, K. B., R. Fatemi, R. Schoephoerster, D. Wurzel, G. Hansen, G. Pantalos, L. S. Yu, and W. J. Kolff. In vitro comparison of velocity profiles and turbulent shear distal to polyurethane trileaflet and pericardial prosthetic valves. Artif. Organs 13(2):148-154, 1989.
    • (1989) Artif. Organs , vol.13 , Issue.2 , pp. 148-154
    • Chandran, K.B.1    Fatemi, R.2    Schoephoerster, R.3    Wurzel, D.4    Hansen, G.5    Pantalos, G.6    Yu, L.S.7    Kolff, W.J.8
  • 6
    • 0029808421 scopus 로고    scopus 로고
    • Velocity measurements and flow patterns within the hinge region of a medtronic parallel bileaflet mechanical valve with clear housing
    • Ellis, J. T., T. M. Healy, A. A. Fontaine, R. Saxena, and A. P. Yoganathan. Velocity measurements and flow patterns within the hinge region of a medtronic parallel bileaflet mechanical valve with clear housing. J. Heart Valve Dis. 5(6):591-599, 1996.
    • (1996) J. Heart Valve Dis. , vol.5 , Issue.6 , pp. 591-599
    • Ellis, J.T.1    Healy, T.M.2    Fontaine, A.A.3    Saxena, R.4    Yoganathan, A.P.5
  • 7
    • 0033966638 scopus 로고    scopus 로고
    • A comparison of the hinge and near-hinge flow fields of the St Jude medical hemodynamic plus and regent bileaflet mechanical heart valves
    • Ellis, J. T. and A. P. Yoganathan. A comparison of the hinge and near-hinge flow fields of the St Jude medical hemodynamic plus and regent bileaflet mechanical heart valves. J. Thorac Cardiovasc. Surg. 119(1):83-93, 2000.
    • (2000) J. Thorac Cardiovasc. Surg. , vol.119 , Issue.1 , pp. 83-93
    • Ellis, J.T.1    Yoganathan, A.P.2
  • 8
    • 0034181001 scopus 로고    scopus 로고
    • An in vitro study of the hinge and near-field forward flow dynamics of the St. Jude Medical Regent bileaflet mechanical heart valve
    • Ellis, J. T., B. R. Travis, and A. P. Yoganathan. An in vitro study of the hinge and near-field forward flow dynamics of the St. Jude Medical Regent bileaflet mechanical heart valve. Ann. Biomed. Eng. 28(5):524-532, 2000.
    • (2000) Ann. Biomed. Eng. , vol.28 , Issue.5 , pp. 524-532
    • Ellis, J.T.1    Travis, B.R.2    Yoganathan, A.P.3
  • 9
    • 0031104939 scopus 로고    scopus 로고
    • An automated method for analysis and visualization of laser Doppler velocimetry data
    • Healy, T. M., J. T. Ellis, A. A. Fontaine, C. A. Jarrett, and A. P. Yoganathan. An automated method for analysis and visualization of laser Doppler velocimetry data. Ann. Biomed. Eng. 25(2):335-343, 1997.
    • (1997) Ann. Biomed. Eng. , vol.25 , Issue.2 , pp. 335-343
    • Healy, T.M.1    Ellis, J.T.2    Fontaine, A.A.3    Jarrett, C.A.4    Yoganathan, A.P.5
  • 10
    • 0002568934 scopus 로고
    • The Helmoltz-institute-tri-leaflet-polyurethane-heart valve prosthesis: Design, manufacturing and first in-vitro and in vivo results
    • edited by H. E. A. Planck. Elsevier Science Publishers
    • Herold, M., H. B. Lo, H. Reul, H. Muckter, K. Taguchi, M. Giesiepen, G. Birkle, G. Hollweg, G. Rau, and B. J. Messmer. The Helmoltz-institute-tri- leaflet-polyurethane-heart valve prosthesis: Design, manufacturing and first in-vitro and in vivo results, In: Polyurethanes in Biomedical Engineering II, edited by H. E. A. Planck. Elsevier Science Publishers, 1987. pp. 231-268.
    • (1987) Polyurethanes in Biomedical Engineering II , pp. 231-268
    • Herold, M.1    Lo, H.B.2    Reul, H.3    Muckter, H.4    Taguchi, K.5    Giesiepen, M.6    Birkle, G.7    Hollweg, G.8    Rau, G.9    Messmer, B.J.10
  • 15
    • 0034879360 scopus 로고    scopus 로고
    • A reevaluation and discussion on the threshold limit for hemolysis in a turbulent shear flow
    • Lu, P. C., H. C. Lai, and J. S. Liu. A reevaluation and discussion on the threshold limit for hemolysis in a turbulent shear flow. J. Biomech. 34(10):1361-1364, 2001.
    • (2001) J. Biomech. , vol.34 , Issue.10 , pp. 1361-1364
    • Lu, P.C.1    Lai, H.C.2    Liu, J.S.3
  • 16
    • 0030269992 scopus 로고    scopus 로고
    • New polyurethane heart valve prosthesis: Design, manufacture and evaluation
    • Mackay, T. G., D. J. Wheatley, G. M. Bernacca, A. C. Fisher, and C. S. Hindle. New polyurethane heart valve prosthesis: Design, manufacture and evaluation. Biomaterials. 17(19):1857-1863, 1996.
    • (1996) Biomaterials , vol.17 , Issue.19 , pp. 1857-1863
    • Mackay, T.G.1    Wheatley, D.J.2    Bernacca, G.M.3    Fisher, A.C.4    Hindle, C.S.5
  • 17
    • 0025797545 scopus 로고
    • The effect of flow on hemostasis and thrombosis
    • Nemerson, Y., and V. T. Turitto. The effect of flow on hemostasis and thrombosis. Thromb. Haemost. 66(3):272-276, 1991.
    • (1991) Thromb. Haemost. , vol.66 , Issue.3 , pp. 272-276
    • Nemerson, Y.1    Turitto, V.T.2
  • 18
    • 0018378290 scopus 로고
    • Shearinduced activation of platelets
    • Ramstack, J. M., L. Zuckerman, and L. E Mockros. Shearinduced activation of platelets. J. Biomech. 12(2):113-125, 1979.
    • (1979) J. Biomech. , vol.12 , Issue.2 , pp. 113-125
    • Ramstack, J.M.1    Zuckerman, L.2    Mockros, L.E.3
  • 19
    • 0021685904 scopus 로고
    • Human red blood cell hemolysis in a turbulent shear flow: Contribution of Reynolds shear stresses
    • Sallam, A. M., and N. H. Hwang. Human red blood cell hemolysis in a turbulent shear flow: Contribution of Reynolds shear stresses. Biorheology 21(6):783-797, 1984.
    • (1984) Biorheology , vol.21 , Issue.6 , pp. 783-797
    • Sallam, A.M.1    Hwang, N.H.2
  • 20
    • 0023470157 scopus 로고
    • Biharmonic spline interpolation of GEOS-3 and SEASAT Altimeter data
    • Sandwell, D. T. Biharmonic spline interpolation of GEOS-3 and SEASAT Altimeter data. Geophys. Res. Lett. (2):139-142, 1987.
    • (1987) Geophys. Res. Lett. , Issue.2 , pp. 139-142
    • Sandwell, D.T.1
  • 21
    • 0347383841 scopus 로고    scopus 로고
    • Extra-cellular matrix degrading enzymes are active in porcine stentless aortic bioprosthetic heart valves
    • Simionescu, D. T., J. J. Lovekamp, and N. R. Vyavahare. Extra-cellular matrix degrading enzymes are active in porcine stentless aortic bioprosthetic heart valves. J. Biomed. Mater. Res. 66A(4):755-763, 2003.
    • (2003) J. Biomed. Mater. Res. , vol.66 A , Issue.4 , pp. 755-763
    • Simionescu, D.T.1    Lovekamp, J.J.2    Vyavahare, N.R.3
  • 22
    • 0027209689 scopus 로고
    • The effects of flow on blood coagulation and thrombosis
    • Slack, S. M., Y. Cui, and V. T. Turitto. The effects of flow on blood coagulation and thrombosis. Thromb. Haemost. 70(1): 129-134, 1993.
    • (1993) Thromb. Haemost. , vol.70 , Issue.1 , pp. 129-134
    • Slack, S.M.1    Cui, Y.2    Turitto, V.T.3
  • 23
    • 0028533507 scopus 로고
    • Platelet size distribution measurements as indicators of shear stress-induced platelet aggregation
    • Slack, S. M., L. K. Jennings, and V. T. Turitto. Platelet size distribution measurements as indicators of shear stress-induced platelet aggregation. Ann. Biomed. Eng. 22(6):653-659, 1994.
    • (1994) Ann. Biomed. Eng. , vol.22 , Issue.6 , pp. 653-659
    • Slack, S.M.1    Jennings, L.K.2    Turitto, V.T.3
  • 24
    • 0028021063 scopus 로고
    • Flow chambers and their standardization for use in studies of thrombosis. On behalf of the subcommittee on rheology of the scientific and standardization committee of the ISTH
    • Slack, S. M., and V. T. Turitto. Flow chambers and their standardization for use in studies of thrombosis. On behalf of the subcommittee on rheology of the scientific and standardization committee of the ISTH. Thromb. Haemost. 72(5):777-781, 1994.
    • (1994) Thromb. Haemost. , vol.72 , Issue.5 , pp. 777-781
    • Slack, S.M.1    Turitto, V.T.2
  • 26
    • 0023861195 scopus 로고
    • Cycle-to-cycle variation effects on turbulent shear stress measurment in pulsatile flows
    • Tiederman, W. G., R. M. Privette, and W. M. Phillips. Cycle-to-cycle variation effects on turbulent shear stress measurment in pulsatile flows. Exp. Fluids. 6:265-272, 1988.
    • (1988) Exp. Fluids. , vol.6 , pp. 265-272
    • Tiederman, W.G.1    Privette, R.M.2    Phillips, W.M.3
  • 27
    • 0032535203 scopus 로고    scopus 로고
    • Mechanical factors affecting hemostasis and thrombosis
    • Turitto, V. T., and C. L. Hall. Mechanical factors affecting hemostasis and thrombosis. Thromb Res. 92(6 Suppl 2):S25-S31, 1998.
    • (1998) Thromb Res. , vol.92 , Issue.6 SUPPL. 2
    • Turitto, V.T.1    Hall, C.L.2
  • 30
    • 0020858055 scopus 로고
    • In vitro fluid dynamic characteristics of the abiomed trileaflet heart valve prosthesis
    • Woo, Y. R., F. P. Williams, and A. P. Yoganathan. In vitro fluid dynamic characteristics of the abiomed trileaflet heart valve prosthesis. J. Biomech. Eng. 105(4):338-345, 1983.
    • (1983) J. Biomech. Eng. , vol.105 , Issue.4 , pp. 338-345
    • Woo, Y.R.1    Williams, F.P.2    Yoganathan, A.P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.