메뉴 건너뛰기




Volumn 20, Issue 6, 1997, Pages 327-331

Polyurethane heart valve durability: Effects of leaflet thickness and material

Author keywords

Durability; Polyurethane; Prosthetic heart valve

Indexed keywords

FATIGUE TESTING; HYDRODYNAMICS; INJECTION MOLDING; POLYURETHANES;

EID: 0030758502     PISSN: 03913988     EISSN: None     Source Type: Journal    
DOI: 10.1177/039139889702000606     Document Type: Article
Times cited : (37)

References (15)
  • 2
    • 0026911796 scopus 로고
    • In vitro calcification of bioprosthetic heart valves: Report of a novel method and review of the biochemical factors involved
    • Bernacca GM, Mackay TG, Wheatley DJ. In vitro calcification of bioprosthetic heart valves: report of a novel method and review of the biochemical factors involved. J Heart Valve Dis 1992; 1: 115-30.
    • (1992) J Heart Valve Dis , vol.1 , pp. 115-130
    • Bernacca, G.M.1    Mackay, T.G.2    Wheatley, D.J.3
  • 3
    • 0011721841 scopus 로고
    • Prosthetic aortic leaflet valve design: Performance analysis of an Avcothane leaflet valve
    • Basel: Karger
    • Ghista DN, Reul H. Prosthetic aortic leaflet valve design: performance analysis of an Avcothane leaflet valve. In: Advances in Cardiovascular Physics. Basel: Karger, 1983; vol. 5, part 4: 31-42.
    • (1983) Advances in Cardiovascular Physics , vol.5 , Issue.4 PART , pp. 31-42
    • Ghista, D.N.1    Reul, H.2
  • 6
    • 0026724633 scopus 로고
    • A synthetic three-leaflet valve
    • Jansen J, Reul H. A synthetic three-leaflet valve. J Med Eng Technol 1992; 16: 27-33.
    • (1992) J Med Eng Technol , vol.16 , pp. 27-33
    • Jansen, J.1    Reul, H.2
  • 10
    • 0031553838 scopus 로고    scopus 로고
    • Polyurethane heart valves: Fatigue failure, calcification and polyurethane structure
    • Bernacca GM, Mackay TG, Wilkinson R, Wheatley DJ. Polyurethane heart valves: fatigue failure, calcification and polyurethane structure. J Biomed Mater Res 1997; 34: 371-9.
    • (1997) J Biomed Mater Res , vol.34 , pp. 371-379
    • Bernacca, G.M.1    Mackay, T.G.2    Wilkinson, R.3    Wheatley, D.J.4
  • 11
    • 0029658660 scopus 로고    scopus 로고
    • In vitro function and durability of a polyurethane heart valve: Material considerations
    • Bernacca GM, Mackay TG, Wheatley DJ. In vitro function and durability of a polyurethane heart valve: material considerations. J Heart Valve Dis 1996; 5: 538-42.
    • (1996) J Heart Valve Dis , vol.5 , pp. 538-542
    • Bernacca, G.M.1    Mackay, T.G.2    Wheatley, D.J.3
  • 13
    • 0024737821 scopus 로고
    • Selected topics in biomedical polyurethanes. A review
    • Gogolewski S. Selected topics in biomedical polyurethanes. A review. Colloid Polym Sci 1989; 267: 757-85.
    • (1989) Colloid Polym Sci , vol.267 , pp. 757-785
    • Gogolewski, S.1