메뉴 건너뛰기




Volumn 14, Issue 5, 2004, Pages 186-197

Time-varying reconstruction in single photon emission computed tomography

Author keywords

Kalman filter; Markov model; Single photon emission computed tomography; Time varying activity

Indexed keywords

BLOOD; COMPUTER SIMULATION; COMPUTERIZED TOMOGRAPHY; IMAGING TECHNIQUES; KALMAN FILTERING; MARKOV PROCESSES; MATHEMATICAL MODELS; PROBLEM SOLVING;

EID: 17644371626     PISSN: 08999457     EISSN: None     Source Type: Journal    
DOI: 10.1002/ima.20023     Document Type: Article
Times cited : (9)

References (39)
  • 1
    • 0023422226 scopus 로고
    • High-speed 3D imaging of the beating heart using temporal estimation
    • R.S. Acharya, P.B. Heffernan, R.A. Robb, and H. Wechsler, High-speed 3D imaging of the beating heart using temporal estimation, Comput Vision Graph 39 (1987), 279-290.
    • (1987) Comput Vision Graph , vol.39 , pp. 279-290
    • Acharya, R.S.1    Heffernan, P.B.2    Robb, R.A.3    Wechsler, H.4
  • 3
    • 0035822416 scopus 로고    scopus 로고
    • Recursive tomographic image reconstruction using a Kalman filter approach in the time domain
    • V.M. Artemiev, A.O. Naumov, and G.-R. Tillack, Recursive tomographic image reconstruction using a Kalman filter approach in the time domain, J Phys D Appl Phys 34 (2001), 2073-2083.
    • (2001) J Phys D Appl Phys , vol.34 , pp. 2073-2083
    • Artemiev, V.M.1    Naumov, A.O.2    Tillack, G.-R.3
  • 5
    • 0017699962 scopus 로고
    • Analysis of EEG signals with changing spectra using a shortword Kalman estimator
    • T. Bohlin, Analysis of EEG signals with changing spectra using a shortword Kalman estimator, Math Biosci 35 (1977), 221-259.
    • (1977) Math Biosci , vol.35 , pp. 221-259
    • Bohlin, T.1
  • 6
    • 0023483347 scopus 로고
    • Artifacts in camera-based single-photon emission tomography due to time activity variation
    • B.D. Bok, A.N. Bice, M. Clausen, D.F. Wong, and H.N. Wagner, Artifacts in camera-based single-photon emission tomography due to time activity variation, Eur J Nucl Med 13 (1987), 439-442.
    • (1987) Eur J Nucl Med , vol.13 , pp. 439-442
    • Bok, B.D.1    Bice, A.N.2    Clausen, M.3    Wong, D.F.4    Wagner, H.N.5
  • 8
    • 0022536597 scopus 로고
    • A maximum likelihood method for region-of-interest evaluation in emission tomography
    • R.E. Carson, A maximum likelihood method for region-of-interest evaluation in emission tomography, J Comput Assist Tomogr 10 (1986), 654-663.
    • (1986) J Comput Assist Tomogr , vol.10 , pp. 654-663
    • Carson, R.E.1
  • 9
    • 0034529901 scopus 로고    scopus 로고
    • Performance of the dynamic single photon emission computed tomography (dSPECT) method for decreasing or increasing activity changes
    • A. Celler, T. Farncombe, D. Noll, R. Harrop, and D. Lyster, Performance of the dynamic single photon emission computed tomography (dSPECT) method for decreasing or increasing activity changes, Phys Med Biol 45 (2000), 3525-3543.
    • (2000) Phys Med Biol , vol.45 , pp. 3525-3543
    • Celler, A.1    Farncombe, T.2    Noll, D.3    Harrop, R.4    Lyster, D.5
  • 10
    • 2042539912 scopus 로고    scopus 로고
    • Reconstructions of gated SPECT myocardial images using a temporal evolution model
    • P. Orangeat and J.-L. Amans, Eds., Kluwer Academic, Dordrecht
    • J. de Murcia and P. Grangeat, Reconstructions of gated SPECT myocardial images using a temporal evolution model, In P. Orangeat and J.-L. Amans, Eds.,Three-dimensional image reconstruction in radiology and nuclear medicine, Kluwer Academic, Dordrecht-1996, pp. 225-241.
    • (1996) Three-dimensional Image Reconstruction in Radiology and Nuclear Medicine , pp. 225-241
    • De Murcia, J.1    Grangeat, P.2
  • 12
    • 0027562466 scopus 로고
    • Least squares algorithm for region-of-interest evaluation in emission tomography
    • A.R. Formiconi, Least squares algorithm for region-of-interest evaluation in emission tomography, IEEE Trans Med Imaging 12 (1993), 90-100.
    • (1993) IEEE Trans Med Imaging , vol.12 , pp. 90-100
    • Formiconi, A.R.1
  • 13
    • 0014550620 scopus 로고
    • The optimum linear smoother as a combination of two optimum linear filters
    • D.C. Fraser and J.E. Potter, The optimum linear smoother as a combination of two optimum linear filters, IEEE Trans Automat Cont 14 (1969), 387-390.
    • (1969) IEEE Trans Automat Cont , vol.14 , pp. 387-390
    • Fraser, D.C.1    Potter, J.E.2
  • 14
    • 5644287341 scopus 로고    scopus 로고
    • A solution to the dynamical inverse problem of EEG generation using spatiotemporal Kalman filtering
    • A. Galka, O. Yamashita, T. Ozaki, R. Biscay, and P. Valdés-Sosa, A solution to the dynamical inverse problem of EEG generation using spatiotemporal Kalman filtering, Neuroimage 23 (2004), 435-453.
    • (2004) Neuroimage , vol.23 , pp. 435-453
    • Galka, A.1    Yamashita, O.2    Ozaki, T.3    Biscay, R.4    Valdés-Sosa, P.5
  • 15
    • 0031342711 scopus 로고    scopus 로고
    • Direct estimation of dynamical parameters in SPECT tomography
    • E. Hebber, D. Oldenburg, T. Farnocombe, and A. Celler, Direct estimation of dynamical parameters in SPECT tomography, IEEE Trans Nucl Sci 44 (1997), 2425-2430.
    • (1997) IEEE Trans Nucl Sci , vol.44 , pp. 2425-2430
    • Hebber, E.1    Oldenburg, D.2    Farnocombe, T.3    Celler, A.4
  • 16
    • 0021151702 scopus 로고
    • A new fast algorithm for the evaluation of regions of interest and statistical uncertainty in computed tomography
    • R.H. Huesman, A new fast algorithm for the evaluation of regions of interest and statistical uncertainty in computed tomography, Phys Med Biol 29 (1984), 543-552.
    • (1984) Phys Med Biol , vol.29 , pp. 543-552
    • Huesman, R.H.1
  • 17
    • 0031982333 scopus 로고    scopus 로고
    • Kinetic parameter estimation from SPECT cone-beam projection measurements
    • R.H. Huesman, B.W. Reutter, G.L. Zeng, and G.T. Gullberg, Kinetic parameter estimation from SPECT cone-beam projection measurements, Phys Med Biol 43 (1998), 973-982.
    • (1998) Phys Med Biol , vol.43 , pp. 973-982
    • Huesman, R.H.1    Reutter, B.W.2    Zeng, G.L.3    Gullberg, G.T.4
  • 18
    • 0026710874 scopus 로고
    • SPECT of rapidly cleared tracers: Imaging a Cheshire cat
    • J.E. Juni, SPECT of rapidly cleared tracers: Imaging a Cheshire cat, J Nucl Med 33 (1992), 1206-1208.
    • (1992) J Nucl Med , vol.33 , pp. 1206-1208
    • Juni, J.E.1
  • 19
    • 0035017354 scopus 로고    scopus 로고
    • 4D maximum a posteriori reconstruction in dynamic SPECT using a compartmental model-based prior
    • D. Kadrmas and G. Gullberg, 4D maximum a posteriori reconstruction in dynamic SPECT using a compartmental model-based prior, Phys Med Biol 46(2001), 1553-1574
    • (2001) Phys Med Biol , vol.46 , pp. 1553-1574
    • Kadrmas, D.1    Gullberg, G.2
  • 20
    • 5644278488 scopus 로고
    • Principles of computerized tomographic imaging
    • New York
    • A.C. Kak and M. Slaney, Principles of computerized tomographic imaging, IEEE Press, New York, 1987.
    • (1987) IEEE Press
    • Kak, A.C.1    Slaney, M.2
  • 21
    • 0021327145 scopus 로고
    • EM reconstruction algorithms for emission and transmission tomography
    • K. Lange and R. Carson, EM reconstruction algorithms for emission and transmission tomography, J Comput Assist Tomogr 8 (1984), 306-316.
    • (1984) J Comput Assist Tomogr , vol.8 , pp. 306-316
    • Lange, K.1    Carson, R.2
  • 24
    • 0026323872 scopus 로고
    • Effect of differential tracer washout during SPECT acquisition
    • J.M. Links, T.L. Frank, and L.C. Becker, Effect of differential tracer washout during SPECT acquisition, J Nucl Med 32 (1991), 2253-2257.
    • (1991) J Nucl Med , vol.32 , pp. 2253-2257
    • Links, J.M.1    Frank, T.L.2    Becker, L.C.3
  • 25
    • 0021375475 scopus 로고
    • Matrix-based image reconstruction methods for tomography
    • J. Llacer, and J.D. Meng, Matrix-based image reconstruction methods for tomography, IEEE Trans Nucl Sci 32 (1985), 855-864.
    • (1985) IEEE Trans Nucl Sci , vol.32 , pp. 855-864
    • Llacer, J.1    Meng, J.D.2
  • 26
    • 0033769588 scopus 로고    scopus 로고
    • Direct recovery of regional tracer kinetics from temporally inconsistent dynamic ECT projections using dimension-reduced time-activity basis
    • J. Maltz, Direct recovery of regional tracer kinetics from temporally inconsistent dynamic ECT projections using dimension-reduced time-activity basis, Phys Med Biol 45 (2000), 3413-3429
    • (2000) Phys Med Biol , vol.45 , pp. 3413-3429
    • Maltz, J.1
  • 29
    • 0025745040 scopus 로고
    • Dynamic acquisition with a three-headed SPECT system: Application to technetium 99m-sq30217 myocardial imaging
    • K. Nakajima, J. Taki, H. Bunko, M. Matsudaira, A. Muramori, I. Matsunari, K. Hisada, and T. Ichihara, Dynamic acquisition with a three-headed SPECT system: Application to Technetium 99m-sq30217 myocardial imaging, J Nucl Med 32 (1991), 1273-1277.
    • (1991) J Nucl Med , vol.32 , pp. 1273-1277
    • Nakajima, K.1    Taki, J.2    Bunko, H.3    Matsudaira, M.4    Muramori, A.5    Matsunari, I.6    Hisada, K.7    Ichihara, T.8
  • 30
    • 0023850041 scopus 로고
    • Dynamic hepatobiliary SPECT: A method for tomography of a changing radioactivity distribution
    • B.E. Oppenheim and J.D. Krepshaw, Dynamic hepatobiliary SPECT: A method for tomography of a changing radioactivity distribution, J Nucl Med 29 (1988), 98-102.
    • (1988) J Nucl Med , vol.29 , pp. 98-102
    • Oppenheim, B.E.1    Krepshaw, J.D.2
  • 31
    • 0032308905 scopus 로고    scopus 로고
    • Kinetic parameter estimation from attenuated SPECT projection measurements
    • B.W. Reutter, G.T. Gullberg, and R.H. Huesman, Kinetic parameter estimation from attenuated SPECT projection measurements, IEEE Trans Nucl Sci 45 (1998), 3007-3013.
    • (1998) IEEE Trans Nucl Sci , vol.45 , pp. 3007-3013
    • Reutter, B.W.1    Gullberg, G.T.2    Huesman, R.H.3
  • 32
    • 0037036603 scopus 로고    scopus 로고
    • Effects of temporal modeling on the statistical uncertainty of spatiotemporal distributions estimated directly from dynamic SPECT projections
    • B.W. Reutter, G.T. Gullberg, and R.H. Huesman, Effects of temporal modeling on the statistical uncertainty of spatiotemporal distributions estimated directly from dynamic SPECT projections, Phys Med Biol 47 (2002), 2673-2683.
    • (2002) Phys Med Biol , vol.47 , pp. 2673-2683
    • Reutter, B.W.1    Gullberg, G.T.2    Huesman, R.H.3
  • 33
    • 1542715852 scopus 로고    scopus 로고
    • Blind identification of the kinetic parameters in three-compartment models
    • D.Y. Riabkov and E.V. Di Bella, Blind identification of the kinetic parameters in three-compartment models, Phys Med Biol 49 (2004), 639-664.
    • (2004) Phys Med Biol , vol.49 , pp. 639-664
    • Riabkov, D.Y.1    Di Bella, E.V.2
  • 36
    • 0028264788 scopus 로고
    • Kinetic modeling of teboroxime using dynamic SPECT imaging of a canine model
    • A.M. Smith, G.T. Gullberg, P.E. Christian, and F.L. Datz, Kinetic modeling of teboroxime using dynamic SPECT imaging of a canine model, J Nucl Med 35 (1994), 484-495.
    • (1994) J Nucl Med , vol.35 , pp. 484-495
    • Smith, A.M.1    Gullberg, G.T.2    Christian, P.E.3    Datz, F.L.4
  • 38
    • 0032053399 scopus 로고    scopus 로고
    • Filter approach to track fast impedance changes in electrical impedance tomography
    • M. Vauhkonen, P.A. Karjalainen J.P. Kaipio, and A Kalman filter approach to track fast impedance changes in electrical impedance tomography, IEEE Trans Biomed Eng 45 (1998), 486-493.
    • (1998) IEEE Trans Biomed Eng , vol.45 , pp. 486-493
    • Vauhkonen, M.1    Karjalainen, P.A.2    Kaipio, J.P.3    Kalman, A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.