Volumn 45, Issue 6 PART 2, 1998, Pages 3007-3013

Kinetic parameter estimation from attenuated spect projection measurements

Author keywords

[No Author keywords available]

Indexed keywords

COMPUTER SIMULATION; COMPUTERIZED TOMOGRAPHY; ESTIMATION; IMAGE RECONSTRUCTION; NUCLEAR MEDICINE; PHARMACOKINETICS;

EID: 0032308905     PISSN: 00189499     EISSN: None     Source Type: Journal    
DOI: 10.1109/23.737657     Document Type: Article
Times cited : (45)

References (17)
  • 3
    • 0029357145 scopus 로고
    • Direct reconstruction of functional parameters for dynamic SPECT
    • [4] G L Zeng, G T Gullberg, and R H Huesman. Using linear time-invariant system theory to estimate kinetic parameters directly from projection measurements. IEEE Trans Niicl Sci., 42(6):2339-2346, 1995.
    • M A Limber, M N Limber, A Celler, J S Barney, and J M Borwein. Direct reconstruction of functional parameters for dynamic SPECT. IEEE Trans Nuct Sci. 42(4): 1249-1256, 1995. [4] G L Zeng, G T Gullberg, and R H Huesman. Using linear time-invariant system theory to estimate kinetic parameters directly from projection measurements. IEEE Trans Niicl Sci., 42(6):2339-2346, 1995.
    • (1995) IEEE Trans Nuct Sci. , vol.42 , Issue.4 , pp. 1249-1256
    • Limber, M.A.1    Limber, M.N.2    Celler, A.3    Barney, J.S.4    Borwein, J.M.5
  • 4
    • 0021151702 scopus 로고
    • A new fast algorithm for the evaluation of regions of interest and statistical uncertainty in computed tomography
    • R H Huesman. A new fast algorithm for the evaluation of regions of interest and statistical uncertainty in computed tomography. PhysMedBiol, 29(5):543-552, 1984.
    • (1984) PhysMedBiol , vol.29 , Issue.5 , pp. 543-552
    • Huesman, R.H.1
  • 5
    • 0025131725 scopus 로고
    • Implementation of three-dimensional image reconstruction for multi-ring positron tomographs
    • M Defrise, D Townsend, and A Geissbuhler. Implementation of three-dimensional image reconstruction for multi-ring positron tomographs. Phys Med Biol, 35(10): 1361-1372, 1990.
    • (1990) Phys Med Biol , vol.35 , Issue.10 , pp. 1361-1372
    • Defrise, M.1    Townsend, D.2    Geissbuhler, A.3
  • 6
    • 0022536597 scopus 로고
    • A maximum likelihood method for region-of-interest evaluation in emission tomography. J
    • R E Carson. A maximum likelihood method for region-of-interest evaluation in emission tomography. J Comput Axsist Tomogr, 10(4):654-663, 1986.
    • (1986) Comput Axsist Tomogr , vol.10 , Issue.4 , pp. 654-663
    • Carson, R.E.1
  • 7
    • 0027562466 scopus 로고
    • Least squares algorithm for region-of-interest evaluation in emission tomography
    • A R Formiconi. Least squares algorithm for region-of-interest evaluation in emission tomography. IEEE Trans Med Imag, 12(1):90-100, 1993.
    • (1993) IEEE Trans Med Imag , vol.12 , Issue.1 , pp. 90-100
    • Formiconi, A.R.1
  • 8
    • 2642684310 scopus 로고    scopus 로고
    • Kinetic parameter estimation from SPECT projection measurements
    • R H Huesman, B W Reutter, G L Zeng, and G T Gullberg. Kinetic parameter estimation from SPECT projection measurements. J Nucl Med, 38(5 suppl):222P-223P. 1997. (abstract).
    • (1997) J Nucl Med , vol.38
    • Huesman, R.H.1    Reutter, B.W.2    Zeng, G.L.3    Gullberg, G.T.4
  • 9
    • 0031982333 scopus 로고    scopus 로고
    • Kinetic parameter estimation from SPECT cone-beam projection measurements
    • R H Huesman, B W Reuttcr, G L Zeng, and G T Gullberg. Kinetic parameter estimation from SPECT cone-beam projection measurements. Phys Med Biol, 43(4):973-982, 1998.
    • (1998) Phys Med Biol , vol.43 , Issue.4 , pp. 973-982
    • Huesman, R.H.1    Reuttcr, B.W.2    Zeng, G.L.3    Gullberg, G.T.4
  • 10
    • 33747385727 scopus 로고
    • A threedimensional mathematical phantom of the human torso for use in SPECT imaging research studies
    • JA Terry, BMW Tsui, J R Perry, and G T Gullberg. A threedimensional mathematical phantom of the human torso for use in SPECT imaging research studies. J Nucl Med, 31(5 suppl):868, 1990. (abstract).
    • (1990) J Nucl Med , vol.31 , pp. 868
    • Terry, J.A.1    Tsui, B.M.W.2    Perry, J.R.3    Gullberg, G.T.4
  • 11
    • 0026545817 scopus 로고
    • Absorbed radiation dose to humans from technetium-99m-teboroxime.
    • R K Narra. T Feld, and A D Nunn. Absorbed radiation dose to humans from technetium-99m-teboroxime. J Nucl Med, 33(1):88-93, 1992.
    • (1992) J Nucl Med , vol.33 , Issue.1 , pp. 88-93
    • Narra, R.K.1    Feld, T.2    Nunn, A.D.3
  • 12
    • 0028264788 scopus 로고
    • A M Smith, G T Gullberg, P E Christian, and F L Datz. Kinetic modeling of teboroxime using dynamic SPECT imaging of a canine model. J Nucl Med, 35(3):984-995, 1994.
    • (1994) Nucl Med , vol.35 , Issue.3 , pp. 984-995
    • Smith, A.M.1    Gullberg, G.T.2    Christian, P.E.3
  • 13
    • 0029995088 scopus 로고    scopus 로고
    • 99mTc-teboroxime kinetic parameters in the myocardium using dynamic SPECT: Reproducibility, correlations to flow, and susceptibility to extravascular contamination
    • 99mTc-teboroxime kinetic parameters in the myocardium using dynamic SPECT: Reproducibility, correlations to flow, and susceptibility to extravascular contamination. J Nucl Cardiol, 3:130-142, 1996.
    • (1996) J Nucl Cardiol , vol.3 , pp. 130-142
    • Smith, A.M.1    Gullberg, G.T.2    Christian, P.E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.