-
1
-
-
1842424647
-
The Chemistry of Thought: Neurotransmitters in the Brain
-
J. N. Stuart, A. B. Hummon, J. V. Sweedler: The Chemistry of Thought: neurotransmitters in the Brain. Anal. Chem. 76, 121A-128A (2004)
-
(2004)
Anal. Chem.
, vol.76
-
-
Stuart, J.N.1
Hummon, A.B.2
Sweedler, J.V.3
-
3
-
-
0033561633
-
Direct immobilization of glutamate dehydrogenase on optical fiber probes for ultrasensitive glutamate detection
-
J. Cordek, X. Wang, W. Tan: Direct immobilization of glutamate dehydrogenase on optical fiber probes for ultrasensitive glutamate detection. Anal. Chem. 71, 1529-1533 (1999)
-
(1999)
Anal. Chem.
, vol.71
, pp. 1529-1533
-
-
Cordek, J.1
Wang, X.2
Tan, W.3
-
4
-
-
0035830786
-
Microdialysis with on-line chemiluminescence detection for the study of nitric oxide release in rat brain following traumatic injury
-
J. Wang, M. Lu, F. Yang, X. Zhang, R. G. Willy, A. M. Baeyens, García Campaña: Microdialysis with on-line chemiluminescence detection for the study of nitric oxide release in rat brain following traumatic injury. Anal. Chim. Acta 428, 173-181 (2001)
-
(2001)
Anal. Chim. Acta
, vol.428
, pp. 173-181
-
-
Wang, J.1
Lu, M.2
Yang, F.3
Zhang, X.4
Willy, R.G.5
Baeyens, A.M.6
Campaña, G.7
-
5
-
-
0026955486
-
Online coupling of in vivo microdialysis with tandem mass spectrometry
-
L. J. Deterding, K. Dix, L. T. Burka, K. B. Tomer: Online coupling of in vivo microdialysis with tandem mass spectrometry. Anal. Chem. 64, 2636-2641 (1992)
-
(1992)
Anal. Chem.
, vol.64
, pp. 2636-2641
-
-
Deterding, L.J.1
Dix, K.2
Burka, L.T.3
Tomer, K.B.4
-
7
-
-
0017242220
-
Probing brain chemistry with electroanalytical technique
-
R. N. Adams: Probing brain chemistry with electroanalytical technique. Anal. Chem. 48, 1128A-1137A (1976)
-
(1976)
Anal. Chem.
, vol.48
-
-
Adams, R.N.1
-
9
-
-
0035144166
-
Increased dopamine release in the human amygdala during performance of cognitive tasks
-
I. Fried, C. L. Wilson, J. W. Morrow, K. A. Cameron, E. D. Behnke, L. C. Ackerson, N. T. Maidment: Increased dopamine release in the human amygdala during performance of cognitive tasks. Nat. Neurosci. 4, 201-206 (2001)
-
(2001)
Nat. Neurosci.
, vol.4
, pp. 201-206
-
-
Fried, I.1
Wilson, C.L.2
Morrow, J.W.3
Cameron, K.A.4
Behnke, E.D.5
Ackerson, L.C.6
Maidment, N.T.7
-
10
-
-
0032190939
-
2+ at carbon-fiber microelectrodes used with fast-scan cyclic voltammetry
-
2+ at carbon-fiber microelectrodes used with fast-scan cyclic voltammetry. J. Neurosci. Meth. 84, 55-62 (1998)
-
(1998)
J. Neurosci. Meth.
, vol.84
, pp. 55-62
-
-
Kume-Kick, J.1
Rice, M.E.2
-
11
-
-
0030176646
-
Overoxidized polypyrrole-coated carbon fiber microelectrodes for dopamine measurements with fast-scan cyclic voltammetry
-
K. Pihel, Q. D. Walker, R. M. Wightman: Overoxidized polypyrrole-coated carbon fiber microelectrodes for dopamine measurements with fast-scan cyclic voltammetry. Anal. Chem. 68, 2084-2089 (1996)
-
(1996)
Anal. Chem.
, vol.68
, pp. 2084-2089
-
-
Pihel, K.1
Walker, Q.D.2
Wightman, R.M.3
-
12
-
-
0002966531
-
Measurement of neurotransmitter release by intracranial dialysis
-
Eds: C. A. Marsden, Wiley: New York
-
U. Ungerstedt: Measurement of neurotransmitter release by intracranial dialysis: In Measurement of Neurotransmitter Release. Eds: C. A. Marsden, Wiley: New York, pp 81-107 (1984)
-
(1984)
Measurement of Neurotransmitter Release
, pp. 81-107
-
-
Ungerstedt, U.1
-
13
-
-
0033168526
-
Rapid determination of aspartate enantiomers in tissue samples by microdialysis coupled on-line with capillary electrophoresis
-
E. T. Jonathan, W. V. Thomas, T. K. Robert: Rapid determination of aspartate enantiomers in tissue samples by microdialysis coupled on-line with capillary electrophoresis. Anal. Chem. 71, 2379-2384 (1999)
-
(1999)
Anal. Chem.
, vol.71
, pp. 2379-2384
-
-
Jonathan, E.T.1
Thomas, W.V.2
Robert, T.K.3
-
14
-
-
0032167558
-
Simultaneous determination of acetylcholine, choline and physostigmine in microdialysis samples from rat hippocampus bymicrobore liquid chromatography/electrochemistry on peroxidase redox polymer coated electrodes
-
J. Kehr, P. Dechent, T. Kato, S. O. Ögren: Simultaneous determination of acetylcholine, choline and physostigmine in microdialysis samples from rat hippocampus bymicrobore liquid chromatography/electrochemistry on peroxidase redox polymer coated electrodes. J. Neurosci. Methods 83, 143-150 (1998)
-
(1998)
J. Neurosci. Methods
, vol.83
, pp. 143-150
-
-
Kehr, J.1
Dechent, P.2
Kato, T.3
Ögren, S.O.4
-
15
-
-
0032546986
-
Simultaneous monitoring of glucose and L-lactic acid during a fermentation process in an aqueous two-phase system by on-line FIA with microdialysis sampling and dual biosensor detection
-
W. M. Rong, V. Rajendrana, N. Larssona, L. Gortona, J. Planasb, B. Hahn-HaÈgerdal: Simultaneous monitoring of glucose and L-lactic acid during a fermentation process in an aqueous two-phase system by on-line FIA with microdialysis sampling and dual biosensor detection. Anal. Chim. Acta 366, 127-135 (1998)
-
(1998)
Anal. Chim. Acta
, vol.366
, pp. 127-135
-
-
Rong, W.M.1
Rajendrana, V.2
Larssona, N.3
Gortona, L.4
Planasb, J.5
Hahn-HaÈgerdal, B.6
-
16
-
-
0032747780
-
An integrated decoupler for capillary electrophoresis with electrochemical detection: Application to analysis of brain microdialysate
-
J. Qian, Y. Wu, H. Yang, A. C. Michael: An integrated decoupler for capillary electrophoresis with electrochemical detection: application to analysis of brain microdialysate. Anal. Chem. 71, 4486-4492 (1999)
-
(1999)
Anal. Chem.
, vol.71
, pp. 4486-4492
-
-
Qian, J.1
Wu, Y.2
Yang, H.3
Michael, A.C.4
-
18
-
-
0029030923
-
Colloidal gold conjugated monoclonal antibodies, studied in the BIAcore biosensor and in the nycocard immunoassay format
-
B. Johne, K. Hansen, E. Mørk, J. Holtlund: Colloidal gold conjugated monoclonal antibodies, studied in the BIAcore biosensor and in the nycocard immunoassay format. J. Immunol. Methods 183, 167-174 (1995)
-
(1995)
J. Immunol. Methods
, vol.183
, pp. 167-174
-
-
Johne, B.1
Hansen, K.2
Mørk, E.3
Holtlund, J.4
-
19
-
-
84908830001
-
Can continuous glucose monitoring be used for the treatment of diabetes
-
G. Reach, G. S. Wilson: Can continuous glucose monitoring be used for the treatment of diabetes. Anal. Chem. 64, 381A-386A (1992)
-
(1992)
Anal. Chem.
, vol.64
-
-
Reach, G.1
Wilson, G.S.2
-
20
-
-
0026926998
-
Enzyme packed bed system for the on-line measurement of glucose, glutamate, and lactate in brain micodialysate
-
M. G. Boutelle, L. K. Fellows, C. Cook: Enzyme packed bed system for the on-line measurement of glucose, glutamate, and lactate in brain micodialysate. Anal. Chem. 64, 1790-1794 (1992)
-
(1992)
Anal. Chem.
, vol.64
, pp. 1790-1794
-
-
Boutelle, M.G.1
Fellows, L.K.2
Cook, C.3
-
21
-
-
0029080348
-
Extracellular glutamate: On-line monitoring using microdialysis coupled to enzyme-amperometric analysis
-
E. Zilkha, T. P. Obrenovitch, A. Koshy, H. Kusakabe, H. P. Bennetto: Extracellular glutamate: on-line monitoring using microdialysis coupled to enzyme-amperometric analysis. J. Neurosci. Methods 60, 1-9 (1995)
-
(1995)
J. Neurosci. Methods
, vol.60
, pp. 1-9
-
-
Zilkha, E.1
Obrenovitch, T.P.2
Koshy, A.3
Kusakabe, H.4
Bennetto, H.P.5
-
22
-
-
0032032903
-
Highly sensitive detection of L-glutamate by on-line amperometric micro-flow analysis based on enzymatic substrate recycling
-
T. Yao, S. Suzuki, T. Nakahara, H. Nishino: Highly sensitive detection of L-glutamate by on-line amperometric micro-flow analysis based on enzymatic substrate recycling. Talanta 45, 917-923 (1998)
-
(1998)
Talanta
, vol.45
, pp. 917-923
-
-
Yao, T.1
Suzuki, S.2
Nakahara, T.3
Nishino, H.4
-
23
-
-
0030181181
-
A damping system for syringe pumps used for microdialysis with on-Line electrochemical detection
-
M. Pravda, C. A. Marvin, S. Sarre, Y. Michotte, J. Kauffmann: A damping system for syringe pumps used for microdialysis with on-Line electrochemical detection. Anal. Chem. 68, 2447-2450 (1996)
-
(1996)
Anal. Chem.
, vol.68
, pp. 2447-2450
-
-
Pravda, M.1
Marvin, C.A.2
Sarre, S.3
Michotte, Y.4
Kauffmann, J.5
-
24
-
-
0030827152
-
On-line in vivo monitoring of endogenous quinones using microdialysis coupled with electrochemical detection
-
M. Pravda, L. Bogaert, S. Sarre, G. Ebinger, J. Kauffmann, Y. Michotte: On-line in vivo monitoring of endogenous quinones using microdialysis coupled with electrochemical detection. Anal. Chem. 69, 2354-2361 (1997)
-
(1997)
Anal. Chem.
, vol.69
, pp. 2354-2361
-
-
Pravda, M.1
Bogaert, L.2
Sarre, S.3
Ebinger, G.4
Kauffmann, J.5
Michotte, Y.6
-
25
-
-
2942598360
-
Simultaneous in vivo monitoring of glucose, L-lactate, and pyruvate concentrations in rat brain by a flow-injection biosensor system with an on-line microdialysis sampling
-
T. Yao, T. Yano, H. Nishino: Simultaneous in vivo monitoring of glucose, L-lactate, and pyruvate concentrations in rat brain by a flow-injection biosensor system with an on-line microdialysis sampling. Anal. Chim. Acta 510, 53-59 (2004)
-
(2004)
Anal. Chim. Acta
, vol.510
, pp. 53-59
-
-
Yao, T.1
Yano, T.2
Nishino, H.3
-
26
-
-
0035943519
-
Improvement in signal reliability when measuring L-glutamate released from cultured cells using multi-channel microfabricated sensors
-
R. Kurita, H. Tabei, K. Hayashi, T. Horiuchi, K. Torimitsu, O. Niwa: Improvement in signal reliability when measuring L-glutamate released from cultured cells using multi-channel microfabricated sensors. Anal. Chim. Acta 441, 165-174 (2001)
-
(2001)
Anal. Chim. Acta
, vol.441
, pp. 165-174
-
-
Kurita, R.1
Tabei, H.2
Hayashi, K.3
Horiuchi, T.4
Torimitsu, K.5
Niwa, O.6
-
27
-
-
0030898093
-
Continuous monitoring of L-glutamate released from cultured nerve cells by an online sensor coupled with micro- capillary sampling
-
O. Niwa, T. Horiuchi, K. Torimitsu: Continuous monitoring of L-glutamate released from cultured nerve cells by an online sensor coupled with micro- capillary sampling. Biosens. Bioelectron. 12, 311-319 (1997)
-
(1997)
Biosens. Bioelectron.
, vol.12
, pp. 311-319
-
-
Niwa, O.1
Horiuchi, T.2
Torimitsu, K.3
-
28
-
-
0034249721
-
Continuous measurement of histamine from rat basophilic leukemia cells (RBL-2H3) with an on-line sensor using histamine oxidase
-
O. Niwa, R. Kurita, K. Hayashi, T. Horiuchi, K. Torimitsu, K. Maeyama, K. Tanizawa: Continuous measurement of histamine from rat basophilic leukemia cells (RBL-2H3) with an on-line sensor using histamine oxidase. Sensors and Actuators B 67, 43-51 (2000)
-
(2000)
Sensors and Actuators B
, vol.67
, pp. 43-51
-
-
Niwa, O.1
Kurita, R.2
Hayashi, K.3
Horiuchi, T.4
Torimitsu, K.5
Maeyama, K.6
Tanizawa, K.7
-
29
-
-
0021020420
-
Brain metabolism: A perspective from the blood-brain barrier
-
W. M. Pardridge: Brain metabolism: a perspective from the blood-brain barrier. Physiol. Rev. 63, 1481-1535 (1983)
-
(1983)
Physiol. Rev.
, vol.63
, pp. 1481-1535
-
-
Pardridge, W.M.1
-
30
-
-
1842734654
-
Glucose transporter expression in the central nervous system: Relationship to synaptic function
-
B. S. McEwen, L. P. Reagan: Glucose transporter expression in the central nervous system: relationship to synaptic function. Europ. J. Pharmaco. 490, 13-24 (2004)
-
(2004)
Europ. J. Pharmaco.
, vol.490
, pp. 13-24
-
-
McEwen, B.S.1
Reagan, L.P.2
-
31
-
-
0032937602
-
Hyperglycemia without hyperinsulinemia produces both sympathetic neural activation and vasodilation in normal humans
-
R. P. Hoffman, M. Hausberg, C. A. Sinkey, E. A. Anderson: Hyperglycemia without hyperinsulinemia produces both sympathetic neural activation and vasodilation in normal humans. J. Diabetes Comp. 13, 17-22 (1999)
-
(1999)
J. Diabetes Comp.
, vol.13
, pp. 17-22
-
-
Hoffman, R.P.1
Hausberg, M.2
Sinkey, C.A.3
Anderson, E.A.4
-
32
-
-
0025105663
-
Effect of post-training injections of glucose on acquisition of two appetitive learning tasks
-
M. G. Packard, N. M. White: Effect of post-training injections of glucose on acquisition of two appetitive learning tasks. Psychobiology 18, 282-286 (1990)
-
(1990)
Psychobiology
, vol.18
, pp. 282-286
-
-
Packard, M.G.1
White, N.M.2
-
33
-
-
0029661937
-
Partitioning of CO2 production between glucose and lactate in excised sympathetic ganglia with implications for brain
-
M. G. Larrabee: Partitioning of CO2 production between glucose and lactate in excised sympathetic ganglia with implications for brain. J. Neurochem. 67, 1726-1734 (1996)
-
(1996)
J. Neurochem.
, vol.67
, pp. 1726-1734
-
-
Larrabee, M.G.1
-
34
-
-
10244223555
-
Electrode systems for continuous monitoring in cardiovascular surgery
-
L. C. Clark Jr., C. Lyons: Electrode systems for continuous monitoring in cardiovascular surgery. Ann. NY Acad. Sci. 102, 29-45 (1962)
-
(1962)
Ann. NY Acad. Sci.
, vol.102
, pp. 29-45
-
-
Clark Jr., L.C.1
Lyons, C.2
-
35
-
-
0030198742
-
Selectivity enhancement for glutamate with a Nafion/glutamate oxidase biosensor
-
S. Pan, A. Arnold: Selectivity enhancement for glutamate with a Nafion/glutamate oxidase biosensor. Talanta 43, 1157-1162 (1996)
-
(1996)
Talanta
, vol.43
, pp. 1157-1162
-
-
Pan, S.1
Arnold, A.2
-
36
-
-
0030471002
-
Flow-injection analysis for hypoxanthine in meat with dissolved oxygen detector and enzyme reactor
-
M. Numata, N. Funazaki, S. Ito, Y. Asano, Y. Yano: Flow-injection analysis for hypoxanthine in meat with dissolved oxygen detector and enzyme reactor. Talanta 43, 2053-2059 (1996)
-
(1996)
Talanta
, vol.43
, pp. 2053-2059
-
-
Numata, M.1
Funazaki, N.2
Ito, S.3
Asano, Y.4
Yano, Y.5
-
37
-
-
0032519105
-
Layer-by-layer construction of enzyme multilayers on an electrode for the preparation of glucose and lactate sensors: Elimination of ascorbate interference by means of an ascorbate oxidase multilayer
-
J. Anzai, H. Takeshita, Y. Kobayashi, T. Osa, T. Hoshi: Layer-by-layer construction of enzyme multilayers on an electrode for the preparation of glucose and lactate sensors: elimination of ascorbate interference by means of an ascorbate oxidase multilayer. Anal. Chem. 70, 811-817 (1998)
-
(1998)
Anal. Chem.
, vol.70
, pp. 811-817
-
-
Anzai, J.1
Takeshita, H.2
Kobayashi, Y.3
Osa, T.4
Hoshi, T.5
-
38
-
-
0033668116
-
Development of an on-line electrochemical biosensor for glucose determination in rat brain using microdialysis sampling
-
M. Pravda, J. Kauffmann, Y. Michotte: Development of an on-line electrochemical biosensor for glucose determination in rat brain using microdialysis sampling. Electroanal. 12, 913-916 (2000)
-
(2000)
Electroanal.
, vol.12
, pp. 913-916
-
-
Pravda, M.1
Kauffmann, J.2
Michotte, Y.3
-
39
-
-
0032063561
-
Plastic film carbon electrodes: Enzymatic modification for on-line, continuous, and simultaneous measurement of lactate and glucose using microdialysis sampling
-
P. G Osborne, O. Niwa, K. Yamamoto: Plastic film carbon electrodes: enzymatic modification for on-line, continuous, and simultaneous measurement of lactate and glucose using microdialysis sampling. Anal. Chem. 70, 1701-1706 (1998)
-
(1998)
Anal. Chem.
, vol.70
, pp. 1701-1706
-
-
Osborne, P.G.1
Niwa, O.2
Yamamoto, K.3
-
40
-
-
0000436609
-
Hydrogen peroxide and β-nicotinamide adenine dinucleotide sensing amperometric electrodes based on electrical connection of horseradish peroxidase redox centers to electrodes through a three-dimensional electron relaying polymer network
-
M. Vreeke, R. Maidan, A. Heller: Hydrogen peroxide and β-nicotinamide adenine dinucleotide sensing amperometric electrodes based on electrical connection of horseradish peroxidase redox centers to electrodes through a three-dimensional electron relaying polymer network. Anal. Chem. 64, 3084-3090 (1992)
-
(1992)
Anal. Chem.
, vol.64
, pp. 3084-3090
-
-
Vreeke, M.1
Maidan, R.2
Heller, A.3
-
41
-
-
0031416690
-
On-line continuous measurement of extracellular striatal glucose using microdialysis sampling and electrochemical detection
-
P. G. Osborne, O. Niwa, T. Kato, K. Yamamoto: On-line continuous measurement of extracellular striatal glucose using microdialysis sampling and electrochemical detection. J. Neurosci. Methods 77, 143-150 (1997)
-
(1997)
J. Neurosci. Methods
, vol.77
, pp. 143-150
-
-
Osborne, P.G.1
Niwa, O.2
Kato, T.3
Yamamoto, K.4
-
42
-
-
0037073464
-
On-line monitoring in neurointensive care enzyme-based electrochemical assay for simultaneous, continuous monitoring of glucose and lactate from critical care patients
-
D. A. Jones, M. C. Parkin, H. Langemann, H. Landolt, S. E. Hopwood, A. J. Strong, M. G. Boutelle: On-line monitoring in neurointensive care enzyme-based electrochemical assay for simultaneous, continuous monitoring of glucose and lactate from critical care patients. J. Electroanal. Chem. 538-539, 243-252 (2002)
-
(2002)
J. Electroanal. Chem.
, vol.538-539
, pp. 243-252
-
-
Jones, D.A.1
Parkin, M.C.2
Langemann, H.3
Landolt, H.4
Hopwood, S.E.5
Strong, A.J.6
Boutelle, M.G.7
-
43
-
-
0037403251
-
Microdevice with integrated dialysis probe and biosensor array for continuous multi-analyte monitoring
-
P. S. Petrou, I. Moser, G. Jobst: Microdevice with integrated dialysis probe and biosensor array for continuous multi-analyte monitoring. Biosens. Bioelectron. 18, 613-619 (2003)
-
(2003)
Biosens. Bioelectron.
, vol.18
, pp. 613-619
-
-
Petrou, P.S.1
Moser, I.2
Jobst, G.3
-
44
-
-
0034325074
-
Miniaturized real-time monitoring system for L-lactate and glucose using microfabricated multi-enzyme sensors
-
J. Perdomo, H. Hinkers, C. Sundermeier, W. Seifert, O. M. Morell, M. Knoll: Miniaturized real-time monitoring system for L-lactate and glucose using microfabricated multi-enzyme sensors. Biosens. Bioelectron. 15, 515-522 (2000)
-
(2000)
Biosens. Bioelectron.
, vol.15
, pp. 515-522
-
-
Perdomo, J.1
Hinkers, H.2
Sundermeier, C.3
Seifert, W.4
Morell, O.M.5
Knoll, M.6
-
45
-
-
0034707715
-
Glucose and choline on-line biosensors based on electropolymerized Meldola's blue
-
L Mao, K. Yamamoto: Glucose and choline on-line biosensors based on electropolymerized Meldola's blue. Talanta 51, 187-195 (2000)
-
(2000)
Talanta
, vol.51
, pp. 187-195
-
-
Mao, L.1
Yamamoto, K.2
-
46
-
-
0032520441
-
On-Line electrochemical sensor for selective continuous measurement of acetylcholine in cultured brain tissue
-
O Niwa, T. Horiuchi, R. Kurita, K. Torimitsu: On-Line electrochemical sensor for selective continuous measurement of acetylcholine in cultured brain tissue. Anal. Chem. 70, 1126-1132 (1998)
-
(1998)
Anal. Chem.
, vol.70
, pp. 1126-1132
-
-
Niwa, O.1
Horiuchi, T.2
Kurita, R.3
Torimitsu, K.4
-
48
-
-
0031602607
-
Small-volume on-line sensor for continuous measurement of γ-aminobutyric acid
-
O. Niwa, R. Kurita, T. Horiuchi, K. Torimitsu: Small-volume on-line sensor for continuous measurement of γ-aminobutyric acid. Anal. Chem. 70, 89-93 (1998)
-
(1998)
Anal. Chem.
, vol.70
, pp. 89-93
-
-
Niwa, O.1
Kurita, R.2
Horiuchi, T.3
Torimitsu, K.4
-
49
-
-
0027476024
-
A synaptic model of memory: Long-term potentiation in the hippocampus
-
T. V. P. Bliss, G. L. Collingridge: A synaptic model of memory: long-term potentiation in the hippocampus. Nature 361, 31-39 (1993)
-
(1993)
Nature
, vol.361
, pp. 31-39
-
-
Bliss, T.V.P.1
Collingridge, G.L.2
-
50
-
-
0022871572
-
Long-term depression as a memory process in the cerebellum
-
M. Ito: Long-term depression as a memory process in the cerebellum. Neurosci. Res. 3, 531-539 (1986)
-
(1986)
Neurosci. Res.
, vol.3
, pp. 531-539
-
-
Ito, M.1
-
51
-
-
0028472185
-
On-Line measurement of brain glutamate with an enzyme/polymer-coated tubular electrode
-
M. O. M. Berners, M. G. Boutelle, M. Fillenz: On-Line measurement of brain glutamate with an enzyme/polymer-coated tubular electrode. Anal. Chem. 66, 2017-2021 (1994)
-
(1994)
Anal. Chem.
, vol.66
, pp. 2017-2021
-
-
Berners, M.O.M.1
Boutelle, M.G.2
Fillenz, M.3
-
52
-
-
0030153490
-
Concentration of extracellular L-glutamate released from cultured nerve cells measured with a small-volume online sensor
-
O. Niwa, K. Torimitsu, M. Morita, P. G. Osborne, K. Yamamoto: Concentration of extracellular L-glutamate released from cultured nerve cells measured with a small-volume online sensor. Anal. Chem. 68, 1865-70 (1996)
-
(1996)
Anal. Chem.
, vol.68
, pp. 1865-1870
-
-
Niwa, O.1
Torimitsu, K.2
Morita, M.3
Osborne, P.G.4
Yamamoto, K.5
-
54
-
-
0030022078
-
Kinetics and performance of a mediated biosensor for hypoxanthine using deflavo xanthine oxidase
-
J. H. T. Luong, R. Thatipamala: Kinetics and performance of a mediated biosensor for hypoxanthine using deflavo xanthine oxidase. Anal. Chim. Acta. 319, 325-333 (1996)
-
(1996)
Anal. Chim. Acta
, vol.319
, pp. 325-333
-
-
Luong, J.H.T.1
Thatipamala, R.2
-
55
-
-
0027993768
-
Fibre-optic biosensor for hypoxanthine and xanthine based on a chemiluminescence reaction
-
J. Hlavay, S. D. Haemmerli, G. G. Guilbault: Fibre-optic biosensor for hypoxanthine and xanthine based on a chemiluminescence reaction. Biosens. Bioelectron. 9, 189-195 (1994)
-
(1994)
Biosens. Bioelectron.
, vol.9
, pp. 189-195
-
-
Hlavay, J.1
Haemmerli, S.D.2
Guilbault, G.G.3
-
56
-
-
0034733774
-
Amperometric on-line sensor for continuous measurement of hypoxanthine based on osmium-polyvinylpyridine gel polymer and xanthine oxidase bienzyme modified glassy carbon electrode
-
L. Mao, K. Yamamoto: Amperometric on-line sensor for continuous measurement of hypoxanthine based on osmium-polyvinylpyridine gel polymer and xanthine oxidase bienzyme modified glassy carbon electrode. Anal. Chim. Acta 415, 143-150 (2000)
-
(2000)
Anal. Chim. Acta
, vol.415
, pp. 143-150
-
-
Mao, L.1
Yamamoto, K.2
-
57
-
-
0037093140
-
Superoxide dismutase-based third-generation biosensor for superoxide anion
-
Y. Tian, L. Mao, T. Okajima, T. Ohsaka: Superoxide dismutase-based third-generation biosensor for superoxide anion. Anal. Chem. 74, 2428-2434 (2002)
-
(2002)
Anal. Chem.
, vol.74
, pp. 2428-2434
-
-
Tian, Y.1
Mao, L.2
Okajima, T.3
Ohsaka, T.4
-
58
-
-
3242662537
-
Electrochemistry and electrocatalytic activities of superoxide dismutases at gold electrodes modified with a self-assembled monolayer
-
Y. Tian, L. Mao, T. Okajima, T. Ohsaka: Electrochemistry and electrocatalytic activities of superoxide dismutases at gold electrodes modified with a self-assembled monolayer; Anal. Chem. 76, 4162-4168 (2004)
-
(2004)
Anal. Chem.
, vol.76
, pp. 4162-4168
-
-
Tian, Y.1
Mao, L.2
Okajima, T.3
Ohsaka, T.4
-
59
-
-
0033119689
-
Superoxide dismutase activity measurement using cytochrome c-modified electrode
-
F. Lisdat, B. Ge, E. Ehrentreich-Forster, R. Reszka, F. W. Scheller: Superoxide dismutase activity measurement using cytochrome c-modified electrode. Anal. Chem. 71, 1359-1365 (1999)
-
(1999)
Anal. Chem.
, vol.71
, pp. 1359-1365
-
-
Lisdat, F.1
Ge, B.2
Ehrentreich-Forster, E.3
Reszka, R.4
Scheller, F.W.5
-
61
-
-
0000813748
-
Applications of "wired" peroxidase electrodes for peroxide determination in liquid chromatography coupled to oxidase immobilized enzyme reactors
-
L. Yang, E. Janle, T. Hiang, J. Gitzen, P. T. Kissinger, M. Vreeke, A. Heller: Applications of "wired" peroxidase electrodes for peroxide determination in liquid chromatography coupled to oxidase immobilized enzyme reactors. Anal. Chem. 67, 1326-1331 (1995)
-
(1995)
Anal. Chem.
, vol.67
, pp. 1326-1331
-
-
Yang, L.1
Janle, E.2
Hiang, T.3
Gitzen, J.4
Kissinger, P.T.5
Vreeke, M.6
Heller, A.7
-
62
-
-
0029644698
-
Polyacrylamide-based redox polymer for connecting redox centers of enzymes to electrodes
-
T. de Lumley-Woodyear, P. Rocca, J. Lindsay, Y. Dror, A. Freeman, A. Heller: Polyacrylamide-based redox polymer for connecting redox centers of enzymes to electrodes. Anal. Chem. 67, 1332-1338 (1995)
-
(1995)
Anal. Chem.
, vol.67
, pp. 1332-1338
-
-
De Lumley-Woodyear, T.1
Rocca, P.2
Lindsay, J.3
Dror, Y.4
Freeman, A.5
Heller, A.6
-
63
-
-
0000953523
-
Characterization of glucose oxidase-modified poly(phenylenediamine)- coated electrodes in vitro and in vivo: Homogeneous interference by ascorbic acid in hydrogen peroxide detection
-
J. P. Lowry, K. McAteer, S. S. E. Atrash, A. Duff, R. D. O'Neil: Characterization of glucose oxidase-modified poly(phenylenediamine)-coated electrodes in vitro and in vivo: homogeneous interference by ascorbic acid in hydrogen peroxide detection. Anal. Chem. 66, 1754-1761 (1994)
-
(1994)
Anal. Chem.
, vol.66
, pp. 1754-1761
-
-
Lowry, J.P.1
McAteer, K.2
Atrash, S.S.E.3
Duff, A.4
O'Neil, R.D.5
-
64
-
-
0027086901
-
Elimination of electrooxidizable interferant-produced currents in amperometric biosensors
-
R. Maidan, A. Heller: Elimination of electrooxidizable interferant-produced currents in amperometric biosensors. Anal. Chem. 64, 2889-2896 (1992)
-
(1992)
Anal. Chem.
, vol.64
, pp. 2889-2896
-
-
Maidan, R.1
Heller, A.2
-
65
-
-
0036683070
-
Continuous on-line measurement of cerebral hydrogen peroxide using enzyme-modified ring-disk plastic carbon film electrode
-
L. Mao, P. G. Osborne, K. Yamamoto, T. Kato: Continuous on-line measurement of cerebral hydrogen peroxide using enzyme-modified ring-disk plastic carbon film electrode. Anal. Chem. 74, 3684-3689 (2002)
-
(2002)
Anal. Chem.
, vol.74
, pp. 3684-3689
-
-
Mao, L.1
Osborne, P.G.2
Yamamoto, K.3
Kato, T.4
|