메뉴 건너뛰기




Volumn 75, Issue 3, 2005, Pages 118-123

Spectral Doppler characterization of endoleaks following endoluminal abdominal aortic aneurysm repair

Author keywords

Aortic aneurysm; Endoluminal repair; Prosthesis; Pulsed Doppler; Ultrasonography

Indexed keywords

ABDOMINAL AORTA ANEURYSM; ANEURYSM SURGERY; ANGIOGRAPHY; AORTA PROSTHESIS; ARTICLE; ARTIFICIAL EMBOLISM; BLOOD FLOW; CASE REPORT; COLOR ULTRASOUND FLOWMETRY; DISEASE CLASSIFICATION; DOPPLER ECHOGRAPHY; ENDOLEAK; ENDOVASCULAR SURGERY; HUMAN; ULTRASOUND SCANNER; WAVEFORM;

EID: 17444366207     PISSN: 14451433     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1445-2197.2005.03313.x     Document Type: Article
Times cited : (2)

References (26)
  • 1
    • 0025821671 scopus 로고
    • Limitations of ultrasonography in surveillance of small abdominal aortic aneurysms
    • Ellis M, Powell JT, Greenhalgh RM. Limitations of ultrasonography in surveillance of small abdominal aortic aneurysms. Br. J. Surg. 1991; 78: 614-16.
    • (1991) Br. J. Surg. , vol.78 , pp. 614-616
    • Ellis, M.1    Powell, J.T.2    Greenhalgh, R.M.3
  • 2
    • 0026321992 scopus 로고
    • Transfemoral intraluminal graft implantation for abdominal aortic aneurysms
    • Parodi JC, Palmaz JC, Barone HD. Transfemoral intraluminal graft implantation for abdominal aortic aneurysms. Ann. Vasc. Surg. 1991; 5: 491-9.
    • (1991) Ann. Vasc. Surg. , vol.5 , pp. 491-499
    • Parodi, J.C.1    Palmaz, J.C.2    Barone, H.D.3
  • 3
    • 0036597160 scopus 로고    scopus 로고
    • Ruptured abdominal aortic aneurysm after endovascular repair
    • Bernhard VM, Mitchell S, Matsumura JS et al. Ruptured abdominal aortic aneurysm after endovascular repair. J. Vasc. Surg. 2002; 35: 115-62.
    • (2002) J. Vasc. Surg. , vol.35 , pp. 115-162
    • Bernhard, V.M.1    Mitchell, S.2    Matsumura, J.S.3
  • 4
    • 0031757739 scopus 로고    scopus 로고
    • Endoleak after aortic stent graft repair: Diagnosis by color duplex ultrasound scan versus computed tomography scan
    • Sato DT, Goff CD, Gregory RT et al. Endoleak after aortic stent graft repair: diagnosis by color duplex ultrasound scan versus computed tomography scan. J. Vasc. Surg. 1998; 28: 657-63.
    • (1998) J. Vasc. Surg. , vol.28 , pp. 657-663
    • Sato, D.T.1    Goff, C.D.2    Gregory, R.T.3
  • 5
    • 0033637752 scopus 로고    scopus 로고
    • Duplex ultrasound scanning versus computed tomography for postoperative evaluation of endovascular abdominal aortic aneurysm repair
    • Wolf YG, Johnson BL, Hill BB, Rubin GD, Fogarty TJ, Zarins CK. Duplex ultrasound scanning versus computed tomography for postoperative evaluation of endovascular abdominal aortic aneurysm repair. J. Vasc. Surg. 2000; 32: 1142-8.
    • (2000) J. Vasc. Surg. , vol.32 , pp. 1142-1148
    • Wolf, Y.G.1    Johnson, B.L.2    Hill, B.B.3    Rubin, G.D.4    Fogarty, T.J.5    Zarins, C.K.6
  • 7
    • 0031886144 scopus 로고    scopus 로고
    • Comparison of computed tomography and duplex imaging in assessing aortic morphology following endovascular aneurysm repair
    • Thompson MM, Boyle JR, Hartshorn T, Maltezos C, Nasim A. Comparison of computed tomography and duplex imaging in assessing aortic morphology following endovascular aneurysm repair. Br. J. Surg. 1998; 85: 346-50.
    • (1998) Br. J. Surg. , vol.85 , pp. 346-350
    • Thompson, M.M.1    Boyle, J.R.2    Hartshorn, T.3    Maltezos, C.4    Nasim, A.5
  • 8
    • 0036634635 scopus 로고    scopus 로고
    • The use of color-flow duplex scan for the detection of endoleaks
    • McLafferty RB, McCrary BS, Mattos MA et al. The use of color-flow duplex scan for the detection of endoleaks. J. Vasc. Surg. 2002; 36: 100-4.
    • (2002) J. Vasc. Surg. , vol.36 , pp. 100-104
    • McLafferty, R.B.1    McCrary, B.S.2    Mattos, M.A.3
  • 9
    • 0033374741 scopus 로고    scopus 로고
    • Abdominal aortic aneurysm wall mechanics and their relation to risk of rupture
    • Sonesson B, Sandgren T, Lanne T. Abdominal aortic aneurysm wall mechanics and their relation to risk of rupture. Eur. J. Vasc. Endovasc. Surg. 1999; 18: 487-93.
    • (1999) Eur. J. Vasc. Endovasc. Surg. , vol.18 , pp. 487-493
    • Sonesson, B.1    Sandgren, T.2    Lanne, T.3
  • 10
    • 0026095765 scopus 로고
    • Determination of expansion rate and incidence of rupture of abdominal aortic aneurysms
    • Limet R, Sakalihassan N, Albert A. Determination of expansion rate and incidence of rupture of abdominal aortic aneurysms. J. Vasc. Surg. 1991; 14, 540-8.
    • (1991) J. Vasc. Surg. , vol.14 , pp. 540-548
    • Limet, R.1    Sakalihassan, N.2    Albert, A.3
  • 11
    • 0038066793 scopus 로고    scopus 로고
    • Aortic side branch perfusion alone does not account for high intra-sac pressure after endovascular repair (EVAR) in the absence of graft-related endoleak
    • Vallabhaneni SR, Gilling-Smith GL, How TV et al. Aortic side branch perfusion alone does not account for high intra-sac pressure after endovascular repair (EVAR) in the absence of graft-related endoleak. Eur. J. Vasc. Endovasc. Surg. 2003; 25: 354-9.
    • (2003) Eur. J. Vasc. Endovasc. Surg. , vol.25 , pp. 354-359
    • Vallabhaneni, S.R.1    Gilling-Smith, G.L.2    How, T.V.3
  • 13
    • 0034519409 scopus 로고    scopus 로고
    • Does complete aneurysm exclusion ensure long-term success after endovascular repair?
    • Lee WA, Wolf YG, Fogarty TJ, Zarins CK. Does complete aneurysm exclusion ensure long-term success after endovascular repair? J. Endovasc. Ther. 2000; 7: 494-500.
    • (2000) J. Endovasc. Ther. , vol.7 , pp. 494-500
    • Lee, W.A.1    Wolf, Y.G.2    Fogarty, T.J.3    Zarins, C.K.4
  • 14
    • 0037284473 scopus 로고    scopus 로고
    • Patency of infrarenal aortic side branches determines early aneurysm sac behaviour after endovascular repair
    • Back MR, Bowser AN, Johnson BL, Schmacht D, Zwiebel B, Bandyk DF. Patency of infrarenal aortic side branches determines early aneurysm sac behaviour after endovascular repair. Ann. Vasc. Surg. 2003; 17: 27-34.
    • (2003) Ann. Vasc. Surg. , vol.17 , pp. 27-34
    • Back, M.R.1    Bowser, A.N.2    Johnson, B.L.3    Schmacht, D.4    Zwiebel, B.5    Bandyk, D.F.6
  • 16
    • 0036188554 scopus 로고    scopus 로고
    • Endoleak: Predictive value for aneurysm growth at 3 years
    • Deaton DH, Makaroun MS, Fairman RM. Endoleak: predictive value for aneurysm growth at 3 years. Ann. Vasc. Surg. 2002; 16: 37-42.
    • (2002) Ann. Vasc. Surg. , vol.16 , pp. 37-42
    • Deaton, D.H.1    Makaroun, M.S.2    Fairman, R.M.3
  • 17
    • 0035433259 scopus 로고    scopus 로고
    • Serious complications that require surgical interventions after endoluminal stent-graft placement for the treatment of infrarenal aortic aneurysms
    • Schlensak C, Doenst T, Hauer M et al. Serious complications that require surgical interventions after endoluminal stent-graft placement for the treatment of infrarenal aortic aneurysms. J. Vasc. Surg. 2001; 34: 198-203.
    • (2001) J. Vasc. Surg. , vol.34 , pp. 198-203
    • Schlensak, C.1    Doenst, T.2    Hauer, M.3
  • 18
    • 0033782683 scopus 로고    scopus 로고
    • Incidence and risk factors of late rupture, conversion, and death after endovascular repair of infrarenal aortic aneurysms: The EUROSTAR experience
    • Harris PL, Vallabhaneni SR, Desgranges P, Becquemin J-P, Marrewijk C, Laheij RJF. Incidence and risk factors of late rupture, conversion, and death after endovascular repair of infrarenal aortic aneurysms: the EUROSTAR experience. J. Vasc. Surg. 2000; 32: 739-49.
    • (2000) J. Vasc. Surg. , vol.32 , pp. 739-749
    • Harris, P.L.1    Vallabhaneni, S.R.2    Desgranges, P.3    Becquemin, J.-P.4    Marrewijk, C.5    Laheij, R.J.F.6
  • 19
    • 0034071614 scopus 로고    scopus 로고
    • Aortic aneurysmal disease: Assessment of stent-graft treatment: CT versus conventional angiography
    • Amerding MD, Rubin GD, Bealieu CF et al. Aortic aneurysmal disease: assessment of stent-graft treatment: CT versus conventional angiography. Radiology 2000; 215: 138-46.
    • (2000) Radiology , vol.215 , pp. 138-146
    • Amerding, M.D.1    Rubin, G.D.2    Bealieu, C.F.3
  • 20
    • 0036831752 scopus 로고    scopus 로고
    • Measuring the abdominal aorta with ultrasonography and computed tomography: Difference and variability
    • Wanhainen A, Bergvist D, Bjorck M. Measuring the abdominal aorta with ultrasonography and computed tomography: difference and variability. Eur. J. Vasc. Endovasc. Surg. 2002; 24: 428-34.
    • (2002) Eur. J. Vasc. Endovasc. Surg. , vol.24 , pp. 428-434
    • Wanhainen, A.1    Bergvist, D.2    Bjorck, M.3
  • 21
    • 0036892607 scopus 로고    scopus 로고
    • Application of Duplex US for characterisation of endoleaks in abdominal aortic stent-grafts: Report of five cases
    • Greenfield AL, Halpern EJ, Bonn J, Wechsler RJ, Kahn MB. Application of Duplex US for characterisation of endoleaks in abdominal aortic stent-grafts: report of five cases. Radiology 2002; 225: 845-51.
    • (2002) Radiology , vol.225 , pp. 845-851
    • Greenfield, A.L.1    Halpern, E.J.2    Bonn, J.3    Wechsler, R.J.4    Kahn, M.B.5
  • 22
    • 19044370276 scopus 로고    scopus 로고
    • The incidence and natural history of type I and II endoleak: A 5-year follow-up assessment with color duplex ultrasound scan
    • Parent FN, Meier GH, Godziachvili V et al. The incidence and natural history of type I and II endoleak: a 5-year follow-up assessment with color duplex ultrasound scan. J. Vasc. Surg. 2002; 35: 474-81.
    • (2002) J. Vasc. Surg. , vol.35 , pp. 474-481
    • Parent, F.N.1    Meier, G.H.2    Godziachvili, V.3
  • 23
    • 0037285780 scopus 로고    scopus 로고
    • Intrasac flow velocities predict sealing of type II endoleaks after endovascular abdominal aortic aneurysm repair
    • Arko FR, Filis KA, Siedel SA et al. Intrasac flow velocities predict sealing of type II endoleaks after endovascular abdominal aortic aneurysm repair. J. Vasc. Surg. 2003; 37: 8-15.
    • (2003) J. Vasc. Surg. , vol.37 , pp. 8-15
    • Arko, F.R.1    Filis, K.A.2    Siedel, S.A.3
  • 24
    • 0346356516 scopus 로고    scopus 로고
    • Doppler waveform assessment of endoleak following endovascular repair of abdominal aortic aneurysm; predictors of endoleak thrombosis
    • Carter KA, Nelms CR, Bloch PHS et al. Doppler waveform assessment of endoleak following endovascular repair of abdominal aortic aneurysm; predictors of endoleak thrombosis. J. Vasc. Technol. 2000; 24: 119-22.
    • (2000) J. Vasc. Technol. , vol.24 , pp. 119-122
    • Carter, K.A.1    Nelms, C.R.2    Bloch, P.H.S.3
  • 25
    • 0024334548 scopus 로고
    • Doppler waveform parvus and tardus: A sign of proximal flow obstruction
    • Kotval PS. Doppler waveform parvus and tardus: a sign of proximal flow obstruction. J. Ultrasound Med. 1989; 8: 435-40.
    • (1989) J. Ultrasound Med. , vol.8 , pp. 435-440
    • Kotval, P.S.1
  • 26
    • 0023871728 scopus 로고
    • The 'to-and-Fro' sign: Duplex Doppler evidence of femoral artery pseudoaneurysm
    • Abu-Yousef MM, Wiese JA, Shamma AR. The 'to-and-Fro' sign: duplex Doppler evidence of femoral artery pseudoaneurysm. AJR 1988; 150: 632-4.
    • (1988) AJR , vol.150 , pp. 632-634
    • Abu-Yousef, M.M.1    Wiese, J.A.2    Shamma, A.R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.