메뉴 건너뛰기




Volumn 24, Issue 2, 2002, Pages 139-145

Intra-aneurysm sac pressure - The Holy Grail of endoluminal grafting of AAA

Author keywords

Aneurysm sac pressure; Open surgery; Stent graft

Indexed keywords

ABDOMINAL AORTA ANEURYSM; ADULT; AGED; ARTICLE; BLOOD VESSEL GRAFT; CLINICAL ARTICLE; CONTROLLED STUDY; CORONARY STENT; ENDOLEAK; ENDOVASCULAR SURGERY; FEMALE; FOLLOW UP; HUMAN; MALE; MESENTERIC ARTERY; PRIORITY JOURNAL; PROSPECTIVE STUDY; SACCULAR ANEURYSM; BLOOD PRESSURE; BLOOD VESSEL TRANSPLANTATION; COMPARATIVE STUDY; EQUIPMENT; MIDDLE AGED; PATHOPHYSIOLOGY; PATIENT MONITORING; PHYSIOLOGY; POSTOPERATIVE COMPLICATION; PREDICTION AND FORECASTING; STENT; TIME; VASCULAR ENDOTHELIUM;

EID: 0036691345     PISSN: 10785884     EISSN: 15322165     Source Type: Journal    
DOI: 10.1053/ejvs.2002.1662     Document Type: Article
Times cited : (42)

References (35)
  • 1
    • 0026321992 scopus 로고
    • Transfemoral intraluminal graft implantation for abdominal aortic aneurysms
    • PARODI JC, PALMAZ JC, BARONE HD. Transfemoral intraluminal graft implantation for abdominal aortic aneurysms. Ann Vasc Surg 1991; 5: 491-499.
    • (1991) Ann Vasc Surg , vol.5 , pp. 491-499
    • Parodi, J.C.1    Palmaz, J.C.2    Barone, H.D.3
  • 2
    • 0026267990 scopus 로고
    • Clinical experience of the use of self-fixing synthetic prostheses for remote endoprosthetics of the thoracic and the abdominal aorta and iliac arteries through the femoral artery and as intraoperative endoprosthesis for aorta reconstruction
    • VOLODOS NL, KARPOVICH IP, TROYAN VI et al. Clinical experience of the use of self-fixing synthetic prostheses for remote endoprosthetics of the thoracic and the abdominal aorta and iliac arteries through the femoral artery and as intraoperative endoprosthesis for aorta reconstruction. Vasa Suppl 1991; 33: 93-95.
    • (1991) Vasa Suppl , vol.33 , pp. 93-95
    • Volodos, N.L.1    Karpovich, I.P.2    Troyan, V.I.3
  • 3
    • 0030072894 scopus 로고    scopus 로고
    • Endoleak - A proposed new terminology to describe incomplete aneurysm exclusion by an endoluminal graft
    • WHITE GH, YU W, MAY J. Endoleak - a proposed new terminology to describe incomplete aneurysm exclusion by an endoluminal graft. J Endovasc Surg 1996; 3: 124-125.
    • (1996) J Endovasc Surg , vol.3 , pp. 124-125
    • White, G.H.1    Yu, W.2    May, J.3
  • 4
    • 0030947672 scopus 로고    scopus 로고
    • Endoleak as a complication of endoluminal grafting of abdominal aortic aneurysms: Classification, incidence, diagnosis, and management
    • WHITE GH, YU W, MAY J, CHAUFOUR X, STEPHEN MS. Endoleak as a complication of endoluminal grafting of abdominal aortic aneurysms: classification, incidence, diagnosis, and management. J Endovasc Surg 1997; 4: 152-168.
    • (1997) J Endovasc Surg , vol.4 , pp. 152-168
    • White, G.H.1    Yu, W.2    May, J.3    Chaufour, X.4    Stephen, M.S.5
  • 5
    • 0033360826 scopus 로고    scopus 로고
    • Endotension after endovascular aneurysm repair: Definition, classification, and strategies for surveillance and intervention
    • GILLING-SMITH G, BRENNAN J, HARRIS P, BAKRAN A, GOULD D, MCWILLIAMS R. Endotension after endovascular aneurysm repair: Definition, classification, and strategies for surveillance and intervention. J Endovasc Surg 1999; 6: 305-307.
    • (1999) J Endovasc Surg , vol.6 , pp. 305-307
    • Gilling-Smith, G.1    Brennan, J.2    Harris, P.3    Bakran, A.4    Gould, D.5    McWilliams, R.6
  • 6
    • 0033364198 scopus 로고    scopus 로고
    • Endotension: An explanation for continued AAA growth after successful endoluminal repair
    • WHITE GH, MAY J, PETRASEK P, WAUGH R, STEPHEN M, HARRIS J. Endotension: An explanation for continued AAA growth after successful endoluminal repair. J Endovasc Surg 1999; 6: 308-315.
    • (1999) J Endovasc Surg , vol.6 , pp. 308-315
    • White, G.H.1    May, J.2    Petrasek, P.3    Waugh, R.4    Stephen, M.5    Harris, J.6
  • 7
    • 0029908463 scopus 로고    scopus 로고
    • Clinical experience with a bifurcated endovascular graft for abdominal aortic aneurysm repair
    • CHUTER TA, RISBERG B, HOPKINSON BR et al. Clinical experience with a bifurcated endovascular graft for abdominal aortic aneurysm repair. J Vasc Surg 1996; 24: 655-666.
    • (1996) J Vasc Surg , vol.24 , pp. 655-666
    • Chuter, T.A.1    Risberg, B.2    Hopkinson, B.R.3
  • 8
    • 0033021397 scopus 로고    scopus 로고
    • Periprosthetic leak and rupture after endovascular repair of abdominal aortic aneurysm: The significance of device design for long-term results
    • KROHG-SORENSEN K, BREKKE M, DROLSUM A, KVERNEBO K. Periprosthetic leak and rupture after endovascular repair of abdominal aortic aneurysm: the significance of device design for long-term results [In Process Citation]. J Vasc Surg 1999; 29: 1152-1158.
    • (1999) J Vasc Surg , vol.29 , pp. 1152-1158
    • Krohg-Sorensen, K.1    Brekke, M.2    Drolsum, A.3    Kvernebo, K.4
  • 9
    • 0031896189 scopus 로고    scopus 로고
    • Clinical consequences of periprosthetic leak after endovascular repair of abdominal aortic aneurysm
    • Endovascular Technologies Investigators
    • MATSUMURA JS, MOORE WS. Clinical consequences of periprosthetic leak after endovascular repair of abdominal aortic aneurysm. Endovascular Technologies Investigators. J Vasc Surg 1998; 27: 606-613.
    • (1998) J Vasc Surg , vol.27 , pp. 606-613
    • Matsumura, J.S.1    Moore, W.S.2
  • 10
    • 0031938732 scopus 로고    scopus 로고
    • Endoleaks after endovascular graft treatment of aortic aneurysms: Classification, risk factors, and outcome
    • WAIN RA, MARIN ML, OHKI T et al. Endoleaks after endovascular graft treatment of aortic aneurysms: classification, risk factors, and outcome. J Vasc Surg 1998; 27: 69-80.
    • (1998) J Vasc Surg , vol.27 , pp. 69-80
    • Wain, R.A.1    Marin, M.L.2    Ohki, T.3
  • 11
    • 0033382713 scopus 로고    scopus 로고
    • Abdominal aortic aneurysm measurements for endovascular repair: Intra- and interobserver variability of CT measurements
    • AARTS NJ, SCHURINK GW, SCHULTZE KOOL LJ et al. Abdominal aortic aneurysm measurements for endovascular repair: intra- and interobserver variability of CT measurements. Eur J Vasc Endovasc Surg 1999; 18: 475-480.
    • (1999) Eur J Vasc Endovasc Surg , vol.18 , pp. 475-480
    • Aarts, N.J.1    Schurink, G.W.2    Schultze Kool, L.J.3
  • 12
    • 0029060108 scopus 로고
    • Variability in measurement of abdominal aortic aneurysms
    • Abdominal Aortic Aneurysm Detection and Management Veterans Administration Cooperative Study Group
    • LEDERLE FA, WILSON SE, JOHNSON GR et al. Variability in measurement of abdominal aortic aneurysms. Abdominal Aortic Aneurysm Detection and Management Veterans Administration Cooperative Study Group. J Vasc Surg 1995; 21: 945-952.
    • (1995) J Vasc Surg , vol.21 , pp. 945-952
    • Lederle, F.A.1    Wilson, S.E.2    Johnson, G.R.3
  • 13
    • 0027282729 scopus 로고
    • Volume blood flow measurements with a transit time flowmeter: An in vivo and in vitro variability and validation study
    • LUNDELL A, BERGQVIST D, MATTSSON E, NILSSON B. Volume blood flow measurements with a transit time flowmeter: an in vivo and in vitro variability and validation study. Clin Physiol 1993; 13: 547-557.
    • (1993) Clin Physiol , vol.13 , pp. 547-557
    • Lundell, A.1    Bergqvist, D.2    Mattsson, E.3    Nilsson, B.4
  • 14
    • 0029774358 scopus 로고    scopus 로고
    • Validation of a new transit time ultrasound flowmeter in man
    • LAUSTSEN J, PEDERSEN EM, TERP K et al. Validation of a new transit time ultrasound flowmeter in man. Eur J Vasc Endovasc Surg 1996; 12: 91-96.
    • (1996) Eur J Vasc Endovasc Surg , vol.12 , pp. 91-96
    • Laustsen, J.1    Pedersen, E.M.2    Terp, K.3
  • 15
    • 19244367643 scopus 로고    scopus 로고
    • Endoleak after endovascular graft repair of experimental aortic aneurysms: Does coil embolization with angiographic "seal" lower intraaneurysmal pressure?
    • MARTY B, SANCHEZ LA, OHKI T et al. Endoleak after endovascular graft repair of experimental aortic aneurysms: does coil embolization with angiographic "seal" lower intraaneurysmal pressure? J Vasc Surg 1998; 27: 454-462.
    • (1998) J Vasc Surg , vol.27 , pp. 454-462
    • Marty, B.1    Sanchez, L.A.2    Ohki, T.3
  • 16
    • 0030818762 scopus 로고    scopus 로고
    • Chronic intraaneurysmal pressure measurement: An experimental method for evaluating the effectiveness of endovascular aortic aneurysm exclusion
    • SANCHEZ LA, FARIES PL, MARIN ML et al. Chronic intraaneurysmal pressure measurement: an experimental method for evaluating the effectiveness of endovascular aortic aneurysm exclusion. J Vasc Surg 1997; 26: 222-230.
    • (1997) J Vasc Surg , vol.26 , pp. 222-230
    • Sanchez, L.A.1    Faries, P.L.2    Marin, M.L.3
  • 18
    • 0030933858 scopus 로고    scopus 로고
    • Aneurysm pressure following endovascular exclusion
    • CHUTER T, IVANCEV K, MALINA M et al. Aneurysm pressure following endovascular exclusion. Eur J Vasc Endovasc Surg 1997; 13: 85-87.
    • (1997) Eur J Vasc Endovasc Surg , vol.13 , pp. 85-87
    • Chuter, T.1    Ivancev, K.2    Malina, M.3
  • 19
    • 0032888367 scopus 로고    scopus 로고
    • Quality control during endovascular aneurysm repair: Monitoring aneurysmal sac pressure and superficial femoral artery flow velocity
    • TREHARNE GD, LOFTUS IM, THOMPSON MM et al. Quality control during endovascular aneurysm repair: monitoring aneurysmal sac pressure and superficial femoral artery flow velocity. J Endovasc Surg 1999; 6: 239-245.
    • (1999) J Endovasc Surg , vol.6 , pp. 239-245
    • Treharne, G.D.1    Loftus, I.M.2    Thompson, M.M.3
  • 20
    • 0030850677 scopus 로고    scopus 로고
    • An experimental model for the acute and chronic evaluation of intra-aneurysmal pressure
    • FARIES PL, SANCHEZ LA, MARIN ML et al. An experimental model for the acute and chronic evaluation of intra-aneurysmal pressure. J Endovasc Surg 1997; 4: 290-297.
    • (1997) J Endovasc Surg , vol.4 , pp. 290-297
    • Faries, P.L.1    Sanchez, L.A.2    Marin, M.L.3
  • 21
    • 0031894283 scopus 로고    scopus 로고
    • Reduced pulsatile wall motion of abdominal aortic aneurysms after endovascular repair
    • MALINA M, LANNE T, IVANCEV K, LINDBLAD B, BRUNKWALL J. Reduced pulsatile wall motion of abdominal aortic aneurysms after endovascular repair. J Vasc Surg 1998; 27: 624-631.
    • (1998) J Vasc Surg , vol.27 , pp. 624-631
    • Malina, M.1    Lanne, T.2    Ivancev, K.3    Lindblad, B.4    Brunkwall, J.5
  • 22
    • 0033785947 scopus 로고    scopus 로고
    • Pulsatile wall motion and blood pressure in aneurysms with open and thrombosed endoleaks-comparison of a wall track system and M-mode ultrasound scanning: An in vitro and animal study
    • SCHURINK GW, AARTS NJ, MALINA M, VAN BOCKEL JH. Pulsatile wall motion and blood pressure in aneurysms with open and thrombosed endoleaks-comparison of a wall track system and M-mode ultrasound scanning: an in vitro and animal study. J Vasc Surg 2000; 32: 795-803.
    • (2000) J Vasc Surg , vol.32 , pp. 795-803
    • Schurink, G.W.1    Aarts, N.J.2    Malina, M.3    Van Bockel, J.H.4
  • 23
    • 0034177344 scopus 로고    scopus 로고
    • Freedom from endoleak after endovascular aneurysm repair does not equal treatment success
    • GILLING-SMITH GL, MARTIN J, SUDHINDRAN S et al. Freedom from endoleak after endovascular aneurysm repair does not equal treatment success. Eur J Vasc Endovasc Surg 2000; 19: 421-425.
    • (2000) Eur J Vasc Endovasc Surg , vol.19 , pp. 421-425
    • Gilling-Smith, G.L.1    Martin, J.2    Sudhindran, S.3
  • 24
    • 0033782683 scopus 로고    scopus 로고
    • Incidence and risk factors of late rupture, conversion, and death after endovascular repair of infrarenal aortic aneurysms: The EUROSTAR experience
    • European Collaborators on Stent/graft techniques for aortic aneurysm repair
    • HARRIS PL, VALLABHANENI SR, DESGRANGES P, BECQUEMIN JP, VAN MARREWIJK C, LAHEIJ RJ. Incidence and risk factors of late rupture, conversion, and death after endovascular repair of infrarenal aortic aneurysms: the EUROSTAR experience. European Collaborators on Stent/graft techniques for aortic aneurysm repair. J Vasc Surg 2000; 32: 739-749.
    • (2000) J Vasc Surg , vol.32 , pp. 739-749
    • Harris, P.L.1    Vallabhaneni, S.R.2    Desgranges, P.3    Becquemin, J.P.4    Van Marrewijk, C.5    Laheij, R.J.6
  • 25
    • 0031453479 scopus 로고    scopus 로고
    • Three-year experience with modular stent-graft devices for endovascular AAA treatment
    • STELTER W, UMSCHEID T, ZIEGLER P. Three-year experience with modular stent-graft devices for endovascular AAA treatment. J Endovasc Surg 1997; 4: 362-369.
    • (1997) J Endovasc Surg , vol.4 , pp. 362-369
    • Stelter, W.1    Umscheid, T.2    Ziegler, P.3
  • 26
    • 0011283290 scopus 로고    scopus 로고
    • Endoleak after stent-graft treatment of abdominal aortic aneurysm: A meta-analysis of clinical studies
    • SCHURINK GW, AARTS NJ, VAN BOCKEL JH. Endoleak after stent-graft treatment of abdominal aortic aneurysm: a meta-analysis of clinical studies. Br J Surg 1999; 86: 581-587.
    • (1999) Br J Surg , vol.86 , pp. 581-587
    • Schurink, G.W.1    Aarts, N.J.2    Van Bockel, J.H.3
  • 27
    • 0031058054 scopus 로고    scopus 로고
    • Changing aneurysmal morphology after endovascular grafting: Relation to leakage or persistent perfusion
    • MALINA M, IVANCEV K, CHUTER TA et al. Changing aneurysmal morphology after endovascular grafting: relation to leakage or persistent perfusion. J Endovasc Surg 1997; 4: 23-30.
    • (1997) J Endovasc Surg , vol.4 , pp. 23-30
    • Malina, M.1    Ivancev, K.2    Chuter, T.A.3
  • 28
    • 0031043728 scopus 로고    scopus 로고
    • Reduction in aortic aneurysm size: Early results after endovascular graft placement
    • EVT Investigators
    • MATSUMURA JS, PEARCE WH, MCCARTHY WJ, YAO JS. Reduction in aortic aneurysm size: early results after endovascular graft placement. EVT Investigators. J Vasc Surg 1997; 25: 113-123.
    • (1997) J Vasc Surg , vol.25 , pp. 113-123
    • Matsumura, J.S.1    Pearce, W.H.2    McCarthy, W.J.3    Yao, J.S.4
  • 30
    • 0034518868 scopus 로고    scopus 로고
    • Does successful embolization of endoleaks lead to aneurysm sac shrinkage?
    • ERMIS C, KRAMER S, TOMCZAK R et al. Does successful embolization of endoleaks lead to aneurysm sac shrinkage? J Endovasc Ther 2000; 7: 441-445.
    • (2000) J Endovasc Ther , vol.7 , pp. 441-445
    • Ermis, C.1    Kramer, S.2    Tomczak, R.3
  • 31
    • 0033782702 scopus 로고    scopus 로고
    • Long-term fate of the aneurysmal sac after endoluminal exclusion of abdominal aortic aneurysms
    • RHEE RY, ESKANDARI MK, ZAJKO AB, MAKAROUN MS. Long-term fate of the aneurysmal sac after endoluminal exclusion of abdominal aortic aneurysms. J Vasc Surg 2000; 32: 689-696.
    • (2000) J Vasc Surg , vol.32 , pp. 689-696
    • Rhee, R.Y.1    Eskandari, M.K.2    Zajko, A.B.3    Makaroun, M.S.4
  • 32
    • 0034526799 scopus 로고    scopus 로고
    • How should endotension be defined? History of a concept and evolution of a new term
    • WHITE GH, MAY J. How should endotension be defined? History of a concept and evolution of a new term. J Endovasc Ther 2000; 7: 435-440.
    • (2000) J Endovasc Ther , vol.7 , pp. 435-440
    • White, G.H.1    May, J.2
  • 34
    • 0034015912 scopus 로고    scopus 로고
    • Diagnosis and treatment of inferior mesenteric arterial endoleaks after endovascular repair of abdominal aortic aneurysms
    • BAUM RA, CARPENTER JP, TUITE CM et al. Diagnosis and treatment of inferior mesenteric arterial endoleaks after endovascular repair of abdominal aortic aneurysms. Radiology 2000; 215: 409-413.
    • (2000) Radiology , vol.215 , pp. 409-413
    • Baum, R.A.1    Carpenter, J.P.2    Tuite, C.M.3
  • 35
    • 0033782708 scopus 로고    scopus 로고
    • Relationship between preoperative patency of the inferior mesenteric artery and subsequent occurrence of type II endoleak in patients undergoing endovascular repair of abdominal aortic aneurysms
    • VELAZQUEZ OC, BAUM RA, CARPENTER JP et al. Relationship between preoperative patency of the inferior mesenteric artery and subsequent occurrence of type II endoleak in patients undergoing endovascular repair of abdominal aortic aneurysms. J Vasc Surg 2000; 32: 777-788.
    • (2000) J Vasc Surg , vol.32 , pp. 777-788
    • Velazquez, O.C.1    Baum, R.A.2    Carpenter, J.P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.