메뉴 건너뛰기




Volumn 2, Issue , 2004, Pages 1067-1070

Simplified gamma-variate fitting of perfusion curves

Author keywords

Brain tumors; Gamma variate; Gliomas; Linear fitting; Perfusion weighted imaging

Indexed keywords

COMPUTER SIMULATION; FUNCTIONS; GAMMA RAYS; IMAGE PROCESSING; LINEARIZATION; MAGNETIC RESONANCE; MONTE CARLO METHODS; SIGNAL PROCESSING; SPURIOUS SIGNAL NOISE; VARIATIONAL TECHNIQUES;

EID: 17144413411     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (30)

References (7)
  • 3
    • 0036238404 scopus 로고    scopus 로고
    • Evaluation of four postprocessing methods for determination of cerebral blood volume and mean transit time by dynamic susceptibility contrast imaging
    • J. Perkiö, H.J. Aronen, A. Kangasmäki, Y. Liu, J. Karonen, S. Savolainen, and L. Østergaard, "Evaluation of four postprocessing methods for determination of cerebral blood volume and mean transit time by dynamic susceptibility contrast imaging," Magn Reson Med, vol. 47, pp. 973-981, 2002.
    • (2002) Magn Reson Med , vol.47 , pp. 973-981
    • Perkiö, J.1    Aronen, H.J.2    Kangasmäki, A.3    Liu, Y.4    Karonen, J.5    Savolainen, S.6    Østergaard, L.7
  • 5
    • 0026633317 scopus 로고
    • A simplified formulation of the gamma variate function
    • M.T. Madsen, "A simplified formulation of the gamma variate function," Phys Med Biol, vol. 37, pp. 1597-1600, 1992.
    • (1992) Phys Med Biol , vol.37 , pp. 1597-1600
    • Madsen, M.T.1
  • 6
    • 0030997814 scopus 로고    scopus 로고
    • Accuracy of gamma-variate fits to concentration-time curves from dynamic susceptibility-contrast enhanced MRI: Influence of time resolution, maximal signal drop and signal-to-noise
    • T. Benner, S. Heiland, G. Erb, M. Forsting, and K. Sartor, "Accuracy of gamma-variate fits to concentration-time curves from dynamic susceptibility-contrast enhanced MRI: influence of time resolution, maximal signal drop and signal-to-noise," Magn Reson Imag, vol. 15, pp. 307-317, 1997.
    • (1997) Magn Reson Imag , vol.15 , pp. 307-317
    • Benner, T.1    Heiland, S.2    Erb, G.3    Forsting, M.4    Sartor, K.5
  • 7
    • 0034027396 scopus 로고    scopus 로고
    • Parametric mapping of scaled fitting error in dynamic susceptibility contrast enhanced MR perfusion imaging
    • K.L. Li, X.P. Zhu, and A. Jackson, "Parametric mapping of scaled fitting error in dynamic susceptibility contrast enhanced MR perfusion imaging," British J Radiol, vol. 73, pp. 470-481, 2000.
    • (2000) British J Radiol , vol.73 , pp. 470-481
    • Li, K.L.1    Zhu, X.P.2    Jackson, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.