메뉴 건너뛰기




Volumn 33, Issue 4, 2005, Pages 898-899

The quest to improve cardiac arrest survival: Overcoming the hemodynamic effects of ventilation

Author keywords

Cardiopulmonary resuscitation; Cardiopulmonary resuscitation impedance threshold device

Indexed keywords

ARTIFICIAL VENTILATION; CARDIAC RESYNCHRONIZATION THERAPY; CORONARY ARTERY BLOOD FLOW; DEVICE; EDITORIAL; ELECTRIC ACTIVITY; HEART ARREST; HEART MUSCLE PERFUSION; HEART OUTPUT; HEART RHYTHM; HEART STROKE VOLUME; HEMODYNAMIC MONITORING; HUMAN; HYPERVENTILATION; PRIORITY JOURNAL; RISK ASSESSMENT; SURVIVAL RATE; THORAX PRESSURE; TREATMENT OUTCOME;

EID: 17044439188     PISSN: 00903493     EISSN: None     Source Type: Journal    
DOI: 10.1097/01.CCM.0000159748.51702.20     Document Type: Editorial
Times cited : (2)

References (17)
  • 1
    • 0012566631 scopus 로고    scopus 로고
    • State specific mortality from sudden cardiac death-United States, 1999
    • Zheng ZJ, Croft JB, Giles WH: State specific mortality from sudden cardiac death-United States, 1999. MMWR Morbid Mortal Wkly Rep 2002; 51:123-126
    • (2002) MMWR Morbid Mortal Wkly Rep , vol.51 , pp. 123-126
    • Zheng, Z.J.1    Croft, J.B.2    Giles, W.H.3
  • 2
    • 11144354509 scopus 로고    scopus 로고
    • Hyperventilation-induced hypotension during cardiopulmonary resuscitation
    • Aufderheide TP, Sigurdsson G, Pirrallo RG, et al: Hyperventilation- induced hypotension during cardiopulmonary resuscitation. Circulation 2004; 109:1960-1965
    • (2004) Circulation , vol.109 , pp. 1960-1965
    • Aufderheide, T.P.1    Sigurdsson, G.2    Pirrallo, R.G.3
  • 3
    • 7244249950 scopus 로고    scopus 로고
    • Death by hyperventilation: A common and life-threatening problem during cardiopulmonary resuscitation
    • Aufderheide TP, Lurie KG: Death by hyperventilation: A common and life-threatening problem during cardiopulmonary resuscitation. Crit Care Med 2004; 32(9 suppl):S345-S351
    • (2004) Crit Care Med , vol.32 , Issue.9 SUPPL.
    • Aufderheide, T.P.1    Lurie, K.G.2
  • 4
    • 0038542823 scopus 로고    scopus 로고
    • Cardiorespiratory interactions and blood flow generation during cardiac arrest and other states of low blood flow
    • Sigurdsson G, Yannopoulos D, McKnite SH, et al: Cardiorespiratory interactions and blood flow generation during cardiac arrest and other states of low blood flow. Curr Opin Crit Care 2003; 9:183-188
    • (2003) Curr Opin Crit Care , vol.9 , pp. 183-188
    • Sigurdsson, G.1    Yannopoulos, D.2    McKnite, S.H.3
  • 5
    • 0038801377 scopus 로고    scopus 로고
    • Emergency ventilatory management in hemorrhagic states: Elemental or detrimental?
    • Pepe PE, Raedler C, Lurie KG, et al: Emergency ventilatory management in hemorrhagic states: Elemental or detrimental? J Trauma 2003; 54:1048-1047
    • (2003) J Trauma , vol.54 , pp. 1048-11047
    • Pepe, P.E.1    Raedler, C.2    Lurie, K.G.3
  • 6
    • 0026726176 scopus 로고
    • Selective aortic arch perfusion during cardiac arrest: A new resuscitation technique
    • Manning JE, Murphy CA Jr, Hertz CM, et al: Selective aortic arch perfusion during cardiac arrest: A new resuscitation technique. Ann Emerg Med 1992; 21:1058-1065
    • (1992) Ann Emerg Med , vol.21 , pp. 1058-1065
    • Manning, J.E.1    Murphy Jr., C.A.2    Hertz, C.M.3
  • 7
    • 0028898134 scopus 로고
    • Active decompression improves the haemodynamic state during cardiopulmonary resuscitation
    • Guly UM, Robertson CE: Active decompression improves the haemodynamic state during cardiopulmonary resuscitation. Br Heart J 1995; 73:372-376
    • (1995) Br Heart J , vol.73 , pp. 372-376
    • Guly, U.M.1    Robertson, C.E.2
  • 8
    • 0029973248 scopus 로고    scopus 로고
    • Hemodynamic effects of active compression-decompression after prolonged CPR
    • Malzer R, Zeiner A, Binder M, et al: Hemodynamic effects of active compression-decompression after prolonged CPR. Resuscitation 1996; 31:243-253
    • (1996) Resuscitation , vol.31 , pp. 243-253
    • Malzer, R.1    Zeiner, A.2    Binder, M.3
  • 9
    • 0031977042 scopus 로고    scopus 로고
    • Optimizing standard cardiopulmonary resuscitation with an inspiratory impedance threshold valve
    • Lurie KG, Mulligan KA, McKnite S, et al: Optimizing standard cardiopulmonary resuscitation with an inspiratory impedance threshold valve. Chest 1998; 113:1084-1090
    • (1998) Chest , vol.113 , pp. 1084-1090
    • Lurie, K.G.1    Mulligan, K.A.2    McKnite, S.3
  • 10
    • 7244227710 scopus 로고    scopus 로고
    • Spontaneous breathing through an inspiratory impedance threshold device augments cardiac index and stroke volume index in a pediatric porcine model of hemorrhagic hypovolemia
    • Marino BS, Yannopoulos D, Sigurdsson G, et al: Spontaneous breathing through an inspiratory impedance threshold device augments cardiac index and stroke volume index in a pediatric porcine model of hemorrhagic hypovolemia. Crit Care Med 2004; 32(9 Suppl):S398-S405
    • (2004) Crit Care Med , vol.32 , Issue.9 SUPPL.
    • Marino, B.S.1    Yannopoulos, D.2    Sigurdsson, G.3
  • 11
    • 1842738291 scopus 로고    scopus 로고
    • Reducing ventilation frequency combined with an inspiratory impedance device improves CPR efficiency in swine model of cardiac arrest
    • Yannopoulos D, Sigurdsson G, McKnite S, et al: Reducing ventilation frequency combined with an inspiratory impedance device improves CPR efficiency in swine model of cardiac arrest. Resuscitation 2004; 61:75-82
    • (2004) Resuscitation , vol.61 , pp. 75-82
    • Yannopoulos, D.1    Sigurdsson, G.2    McKnite, S.3
  • 12
    • 0038521367 scopus 로고    scopus 로고
    • Evaluation of a prototypic inspiratory impedance threshold valve designed to enhance the efficiency of cardiopulmonary resuscitation
    • Lurie KG, Barnes TA, Zielinski TM, et al: Evaluation of a prototypic inspiratory impedance threshold valve designed to enhance the efficiency of cardiopulmonary resuscitation. Respir Care 2003; 48:52-57
    • (2003) Respir Care , vol.48 , pp. 52-57
    • Lurie, K.G.1    Barnes, T.A.2    Zielinski, T.M.3
  • 13
    • 0033710526 scopus 로고    scopus 로고
    • Improving the efficiency of cardiopulmonary resuscitation with an inspiratory impedance threshold valve
    • Lurie K, Zielinski T, McKnite S, et al: Improving the efficiency of cardiopulmonary resuscitation with an inspiratory impedance threshold valve. Crit Care Med 2000; 28(11 Suppl):N207-N209
    • (2000) Crit Care Med , vol.28 , Issue.11 SUPPL.
    • Lurie, K.1    Zielinski, T.2    McKnite, S.3
  • 14
    • 17044425083 scopus 로고    scopus 로고
    • Clinical evaluation of an inspiratory impedance threshold device during standard cardiopulmonary resuscitation in patients with out-of-hospital cardiac arrest
    • Aufderheide TP, Pirrallo RG, Provo TA, et al: Clinical evaluation of an inspiratory impedance threshold device during standard cardiopulmonary resuscitation in patients with out-of-hospital cardiac arrest Crit Care Med 2005; 33:734-740
    • (2005) Crit Care Med , vol.33 , pp. 734-740
    • Aufderheide, T.P.1    Pirrallo, R.G.2    Provo, T.A.3
  • 15
    • 2542456619 scopus 로고    scopus 로고
    • Evaluation of an impedance threshold device in patients receiving active compression-decompression cardiopulmonary resuscitation for out of hospital cardiac arrest
    • Plaisance P, Lurie KG, Vicaut E, et al: Evaluation of an impedance threshold device in patients receiving active compression-decompression cardiopulmonary resuscitation for out of hospital cardiac arrest. Resuscitation 2004; 61:265-271
    • (2004) Resuscitation , vol.61 , pp. 265-271
    • Plaisance, P.1    Lurie, K.G.2    Vicaut, E.3
  • 16
    • 0242361648 scopus 로고    scopus 로고
    • Comparison of standard cardiopulmonary resuscitation versus the combination of active compression-decompression cardiopulmonary resuscitation and an inspiratory impedance threshold device for out-of-hospital cardiac arrest
    • Wolcke BB, Mauer DK, Schoefmann MF, et al: Comparison of standard cardiopulmonary resuscitation versus the combination of active compression-decompression cardiopulmonary resuscitation and an inspiratory impedance threshold device for out-of-hospital cardiac arrest. Circulation 2003; 108:2201-2205
    • (2003) Circulation , vol.108 , pp. 2201-2205
    • Wolcke, B.B.1    Mauer, D.K.2    Schoefmann, M.F.3
  • 17
    • 4644235585 scopus 로고    scopus 로고
    • Combination of active compression decompression cardiopulmonary resuscitation and the inspiratory impedance threshold device: State of the art
    • Frascone RJ, Bitz D, Lurie K: Combination of active compression decompression cardiopulmonary resuscitation and the inspiratory impedance threshold device: state of the art. Curr Opin Crit Care 2004; 10:193-201
    • (2004) Curr Opin Crit Care , vol.10 , pp. 193-201
    • Frascone, R.J.1    Bitz, D.2    Lurie, K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.