메뉴 건너뛰기




Volumn 22, Issue 2, 2005, Pages 153-158

Differences in MEG/EEC epileptic spike yields explained by regional differences in signal-to-noise ratios

Author keywords

EEG; Epilepsy; MEG; Signal to noise ratio

Indexed keywords

ARTICLE; ELECTROENCEPHALOGRAM; EPILEPTIC DISCHARGE; FRONTAL LOBE; HUMAN; HUMAN EXPERIMENT; HUMAN TISSUE; INTERMETHOD COMPARISON; MAGNETOENCEPHALOGRAPHY; MATHEMATICAL COMPUTING; NEOCORTEX; NORMAL HUMAN; PREOPERATIVE EVALUATION; SENSOR; SIGNAL NOISE RATIO; SKULL; SPIKE WAVE; TEMPORAL LOBE EPILEPSY; ACTION POTENTIAL; BRAIN MAPPING; ELECTROENCEPHALOGRAPHY; EPILEPSY; METHODOLOGY; PATHOPHYSIOLOGY; PHYSIOLOGY;

EID: 16844372339     PISSN: 07360258     EISSN: None     Source Type: Journal    
DOI: 10.1097/01.WNP.0000158947.68733.51     Document Type: Article
Times cited : (76)

References (19)
  • 1
    • 1842422257 scopus 로고    scopus 로고
    • Controversies in neurophysiology, MEG is superior to EEG in localization of interictal epileptiform activity: Pro
    • Barkley GL. (2004) Controversies in neurophysiology. MEG is superior to EEG in localization of interictal epileptiform activity: pro. Clin Neurophysiol 115:1001-9.
    • (2004) Clin Neurophysiol , vol.115 , pp. 1001-1009
    • Barkley, G.L.1
  • 3
    • 1842612074 scopus 로고    scopus 로고
    • Controversies in neurophysiology. MEG is superior to EEG in localization of interictal epileptiform activity: Con
    • Baumgartner C. (2004) Controversies in neurophysiology. MEG is superior to EEG in localization of interictal epileptiform activity: con. Clin Neurophysiol 115:1010-20.
    • (2004) Clin Neurophysiol , vol.115 , pp. 1010-1020
    • Baumgartner, C.1
  • 5
    • 0020522807 scopus 로고
    • Demonstration of useful differences between magnetoencephalogram and electroencephalogram
    • Cohen D, Cuffin BN. (1983) Demonstration of useful differences between magnetoencephalogram and electroencephalogram. Electroencephalogr Clin Neurophysiol 56:38-51.
    • (1983) Electroencephalogr Clin Neurophysiol , vol.56 , pp. 38-51
    • Cohen, D.1    Cuffin, B.N.2
  • 7
    • 0033855918 scopus 로고    scopus 로고
    • The application of electrical impedance tomography to reduce systematic errors in the EEG inverse problem-a simulation study
    • Gonçalves S, de Munck JC, Heethaar RM, Lopes da Silva FH, van Dijk BW. The application of electrical impedance tomography to reduce systematic errors in the EEG inverse problem-a simulation study. Physiol Meas 2000;21:379-93.
    • (2000) Physiol Meas , vol.21 , pp. 379-393
    • Gonçalves, S.1    De Munck, J.C.2    Heethaar, R.M.3    Lopes Da Silva, F.H.4    Van Dijk, B.W.5
  • 8
    • 0038274527 scopus 로고    scopus 로고
    • In vivo measurement of the brain and skull resistivities using an EIT-based method and realistic models for the head
    • Gonçalves SI, de Munck JC, Verbunt PA, et al. In vivo measurement of the brain and skull resistivities using an EIT-based method and realistic models for the head. IEEE Trans Biomed Eng 2003;50:754-67.
    • (2003) IEEE Trans Biomed Eng , vol.50 , pp. 754-767
    • Gonçalves, S.I.1    De Munck, J.C.2    Verbunt, P.A.3
  • 9
    • 0016128650 scopus 로고
    • A glossary of terms commonly used by clinical electroencephalographers
    • IFSECN. A glossary of terms commonly used by clinical electroencephalographers. Electroencephalogr Clin Neurophysiol 1974;37:538-48.
    • (1974) Electroencephalogr Clin Neurophysiol , vol.37 , pp. 538-548
  • 11
    • 0141891404 scopus 로고    scopus 로고
    • High-resolution source imaging in mesiotemporal lobe epilepsy: A comparison between MEG and simultaneous EEG
    • Leijten FSS, Huiskamp GJM, Hilgersom I, et al. (2003) High-resolution source imaging in mesiotemporal lobe epilepsy: A comparison between MEG and simultaneous EEG. J Clin Neurophysiol 20:227-38.
    • (2003) J Clin Neurophysiol , vol.20 , pp. 227-238
    • Leijten, F.S.S.1    Huiskamp, G.J.M.2    Hilgersom, I.3
  • 12
    • 1842579394 scopus 로고    scopus 로고
    • MEG: Good enough
    • Lesser RP. (2004) MEG: good enough. Clin Neurophysiol 115:995-7.
    • (2004) Clin Neurophysiol , vol.115 , pp. 995-997
    • Lesser, R.P.1
  • 15
    • 0035201490 scopus 로고    scopus 로고
    • A fast method to derive realistic BEM models for E/MEG source reconstruction
    • Van't Ent D, De Munck JC, Kaas AL. A fast method to derive realistic BEM models for E/MEG source reconstruction. IEEE Trans Biomed Eng 2001; 48:1434-43.
    • (2001) IEEE Trans Biomed Eng , vol.48 , pp. 1434-1443
    • Van't Ent, D.1    De Munck, J.C.2    Kaas, A.L.3
  • 16
    • 0642311112 scopus 로고    scopus 로고
    • Spike cluster analysis in neocortical localization related epilepsy yields clinically significant equivalent source localization results in magnetoencephalogram (MEG)
    • Van't Ent D, Manshanden I, Ossenblok P, Velis DN, de Munck JC, Verbunt JPA, da Silva FHL. Spike cluster analysis in neocortical localization related epilepsy yields clinically significant equivalent source localization results in magnetoencephalogram (MEG). Clin Neurophysiol 2003;114:1948-62.
    • (2003) Clin Neurophysiol , vol.114 , pp. 1948-1962
    • Van't Ent, D.1    Manshanden, I.2    Ossenblok, P.3    Velis, D.N.4    De Munck, J.C.5    Verbunt, J.P.A.6    Da Silva, F.H.L.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.