메뉴 건너뛰기




Volumn 26, Issue 3, 2005, Pages 578-584

Evaluation of a signal intensity mask in the interpretation of functional MR imaging activation maps

Author keywords

[No Author keywords available]

Indexed keywords

AIR; ARTICLE; ARTIFACT; ARTIFICIAL EMBOLISM; BLOOD; BRAIN CORTEX; BRAIN REGION; DENTAL DEVICE; ECHO PLANAR IMAGING; FAHR DISEASE; FUNCTIONAL MAGNETIC RESONANCE IMAGING; HUMAN; MAJOR CLINICAL STUDY; BRAIN DISEASE; BRAIN MAPPING; EVALUATION; MAGNETISM; METHODOLOGY; NUCLEAR MAGNETIC RESONANCE IMAGING; RETROSPECTIVE STUDY; SINGLE BLIND PROCEDURE;

EID: 16844363382     PISSN: 01956108     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (8)

References (22)
  • 1
    • 0038787548 scopus 로고    scopus 로고
    • Functional magnetic resonance imaging: A review of methodological aspects and clinical applications
    • Hennig J, Speck O, Koch MA, Walker C. Functional magnetic resonance imaging: a review of methodological aspects and clinical applications. J Magn Reson Imaging 2003;18:1-15
    • (2003) J Magn Reson Imaging , vol.18 , pp. 1-15
    • Hennig, J.1    Speck, O.2    Koch, M.A.3    Walker, C.4
  • 2
    • 0033919303 scopus 로고    scopus 로고
    • Susceptibility-induced loss of signal: Comparing PET and fMRI on a semantic task
    • Devlin JT, Russell RP, Davis MH, et al. Susceptibility-induced loss of signal: comparing PET and fMRI on a semantic task. Neuroimage 2000;11:589-600
    • (2000) Neuroimage , vol.11 , pp. 589-600
    • Devlin, J.T.1    Russell, R.P.2    Davis, M.H.3
  • 3
    • 0035091609 scopus 로고    scopus 로고
    • Neuroimaging at 1.5 T and 3.0 T: Comparison of oxygenation-sensitive magnetic resonance imaging
    • Kruger G, Kastrup A, Glover GH. Neuroimaging at 1.5 T and 3.0 T: comparison of oxygenation-sensitive magnetic resonance imaging. Magn Reson Med 2001;45:595-604
    • (2001) Magn Reson Med , vol.45 , pp. 595-604
    • Kruger, G.1    Kastrup, A.2    Glover, G.H.3
  • 4
    • 0030714180 scopus 로고    scopus 로고
    • Anatomic localization and quantitative analysis of gradient refocused echo-planar fMRI susceptibility artifacts
    • Ojemann JG, Akbudak E, Snyder AZ, McKinstry RC, Raichle ME, Conturo TE. Anatomic localization and quantitative analysis of gradient refocused echo-planar fMRI susceptibility artifacts. Neuroimage 1997;6:156-167
    • (1997) Neuroimage , vol.6 , pp. 156-167
    • Ojemann, J.G.1    Akbudak, E.2    Snyder, A.Z.3    McKinstry, R.C.4    Raichle, M.E.5    Conturo, T.E.6
  • 5
    • 3242802884 scopus 로고    scopus 로고
    • Applications and limitations of perfusion-dependent functional brain mapping for neurosurgical guidance
    • Article 2
    • Pouratian N, Sheth S, Bookheimer SY, Martin NA, Toga AW. Applications and limitations of perfusion-dependent functional brain mapping for neurosurgical guidance. Neurosurg Focus 2003; 15: Article 2
    • (2003) Neurosurg Focus , vol.15
    • Pouratian, N.1    Sheth, S.2    Bookheimer, S.Y.3    Martin, N.A.4    Toga, A.W.5
  • 8
    • 0036240237 scopus 로고    scopus 로고
    • Cerebral oxygen extraction fraction and cerebral venous blood volume measurements using MRI: Effects of magnetic field variation
    • An H, Lin W. Cerebral oxygen extraction fraction and cerebral venous blood volume measurements using MRI: effects of magnetic field variation. Magn Reson Med 2002;47:958-966
    • (2002) Magn Reson Med , vol.47 , pp. 958-966
    • An, H.1    Lin, W.2
  • 9
    • 0029034190 scopus 로고
    • Correction for geometric distortion in echo planar images from B0 field variations
    • Jezzard P, Balaban RS. Correction for geometric distortion in echo planar images from B0 field variations. Magn Reson Med 1995;34:65-73
    • (1995) Magn Reson Med , vol.34 , pp. 65-73
    • Jezzard, P.1    Balaban, R.S.2
  • 10
    • 0037330814 scopus 로고    scopus 로고
    • Single-shot T2* mapping with 3D compensation of local susceptibility gradients in multiple regions
    • Posse S, Shen Z, Kiselev V, Kemna LJ. Single-shot T2* mapping with 3D compensation of local susceptibility gradients in multiple regions. Neuroimage 2003;18:390-400
    • (2003) Neuroimage , vol.18 , pp. 390-400
    • Posse, S.1    Shen, Z.2    Kiselev, V.3    Kemna, L.J.4
  • 11
    • 0036328751 scopus 로고    scopus 로고
    • Multiecho segmented EPI with Z-shimmed background gradient compensation (MESBAC) pulse sequence for fMRI
    • Li Z, Wu G, Zhao X, Luo F, Li S-J. Multiecho segmented EPI with Z-shimmed background gradient compensation (MESBAC) pulse sequence for fMRI. Magn Reson Med 2002;48:312-321
    • (2002) Magn Reson Med , vol.48 , pp. 312-321
    • Li, Z.1    Wu, G.2    Zhao, X.3    Luo, F.4    Li, S.-J.5
  • 12
    • 0034894659 scopus 로고    scopus 로고
    • Single-shot EPI with signal recovery from the susceptibility induced losses
    • Song AW. Single-shot EPI with signal recovery from the susceptibility induced losses. Magn Reson Med 2001;46:407-411
    • (2001) Magn Reson Med , vol.46 , pp. 407-411
    • Song, A.W.1
  • 13
    • 0032868199 scopus 로고    scopus 로고
    • 3D z-shim method for reduction of susceptibility effects in BOLD fMRI
    • Glover GH. 3D z-shim method for reduction of susceptibility effects in BOLD fMRI. Magn Reson Med 1999;42:290-299
    • (1999) Magn Reson Med , vol.42 , pp. 290-299
    • Glover, G.H.1
  • 14
    • 0034529949 scopus 로고    scopus 로고
    • Compensation of susceptibility-induced signal loss in echo-planar imaging for functional applications
    • Cordes D, Turski PA, Sorenson JA. Compensation of susceptibility-induced signal loss in echo-planar imaging for functional applications. Magn Reson Imaging 2000;18:1055-068
    • (2000) Magn Reson Imaging , vol.18 , pp. 1055-1068
    • Cordes, D.1    Turski, P.A.2    Sorenson, J.A.3
  • 15
    • 0036328933 scopus 로고    scopus 로고
    • Compensation of susceptibility-induced BOLD sensitivity losses in echo-planar fMRI imaging
    • Deichmann R, Josphs O, Hutton C, Corfield DR, Turner R. Compensation of susceptibility-induced BOLD sensitivity losses in echo-planar fMRI imaging. Neuroimage 2002;15:120-135
    • (2002) Neuroimage , vol.15 , pp. 120-135
    • Deichmann, R.1    Josphs, O.2    Hutton, C.3    Corfield, D.R.4    Turner, R.5
  • 16
    • 0025298010 scopus 로고
    • Analysis of T2 limitations and off-resonance effects on spatial resolution and artifacts in echo-planar imaging
    • Farzaneh F, Riederer SJ, Pelc NJ. Analysis of T2 limitations and off-resonance effects on spatial resolution and artifacts in echo-planar imaging. Magn Reson Med 1990;14:123-139
    • (1990) Magn Reson Med , vol.14 , pp. 123-139
    • Farzaneh, F.1    Riederer, S.J.2    Pelc, N.J.3
  • 18
    • 0029911435 scopus 로고    scopus 로고
    • Three-dimensional mapping of the static magnetic field inside the human head
    • Li S, Dardzinski BJ, Collins CM, Yang QX, Smith MB. Three-dimensional mapping of the static magnetic field inside the human head. Magn Reson Med 1996;36:705-714
    • (1996) Magn Reson Med , vol.36 , pp. 705-714
    • Li, S.1    Dardzinski, B.J.2    Collins, C.M.3    Yang, Q.X.4    Smith, M.B.5
  • 20
    • 0030961924 scopus 로고    scopus 로고
    • Spatially filtering functional magnetic resonance imaging data
    • Lowe MJ, Sorenson JA. Spatially filtering functional magnetic resonance imaging data. Magn Reson Med 1997;37:723-729
    • (1997) Magn Reson Med , vol.37 , pp. 723-729
    • Lowe, M.J.1    Sorenson, J.A.2
  • 21
    • 0030175198 scopus 로고    scopus 로고
    • AFNI: Software for analysis and visualization of functional magnetic resonance neuroimages
    • Cox RW. AFNI: Software for analysis and visualization of functional magnetic resonance neuroimages. Comput Biomed Res 1996;29:162-173
    • (1996) Comput Biomed Res , vol.29 , pp. 162-173
    • Cox, R.W.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.