메뉴 건너뛰기




Volumn 24, Issue 6, 2004, Pages 520-527

Measurement of refractive error and accommodation with the photorefractor PowerRef II

Author keywords

Accommodation; Automated photorefraction; PowerRef II; PowerRefractor; Pupil size

Indexed keywords

ACCOMMODATION; ARTICLE; CLINICAL ARTICLE; DISTANCE PERCEPTION; EYE PHOTOGRAPHY; FREQUENCY ANALYSIS; HUMAN; HYPERMETROPIA; INFRARED PHOTOGRAPHY; OPTICAL INSTRUMENTATION; OPTOMETRY; PRIORITY JOURNAL; PUPIL; REFRACTION ERROR; RELIABILITY; ADULT; EVALUATION; EYE REFRACTION; INSTRUMENTATION; REPRODUCIBILITY; VISUAL SYSTEM EXAMINATION;

EID: 16644376217     PISSN: 02755408     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1475-1313.2004.00233.x     Document Type: Article
Times cited : (26)

References (14)
  • 1
    • 0346899567 scopus 로고    scopus 로고
    • Clinical evaluation of an eccentric infrared photorefractor: The PowerRefractor
    • Abrahamsson, M., Ohlsson, J., Bjorndahl, M. and Abrahamsson, H. (2003) Clinical evaluation of an eccentric infrared photorefractor: the PowerRefractor. Acta Ophthalmol. Scand. 81, 605-610.
    • (2003) Acta Ophthalmol. Scand. , vol.81 , pp. 605-610
    • Abrahamsson, M.1    Ohlsson, J.2    Bjorndahl, M.3    Abrahamsson, H.4
  • 2
    • 0037343748 scopus 로고    scopus 로고
    • Repeatability and validity of the PowerRefractor and the Nidek AR600-A in a adult population with healthy eyes
    • Allen, P. M., Radhakrishnan, H. and O'Leary, D. J. (2003) Repeatability and validity of the PowerRefractor and the Nidek AR600-A in a adult population with healthy eyes. Optom. Vis. Sci. 80, 245-251.
    • (2003) Optom. Vis. Sci. , vol.80 , pp. 245-251
    • Allen, P.M.1    Radhakrishnan, H.2    O'Leary, D.J.3
  • 3
    • 0021812523 scopus 로고
    • Eccentric photorefraction: Optical analysis and empirical measures
    • Bobier, W. R. and Braddick, O. J. (1985) Eccentric photorefraction: optical analysis and empirical measures. Am. J. Optom. Physiol. Opt. 62, 614-620.
    • (1985) Am. J. Optom. Physiol. Opt. , vol.62 , pp. 614-620
    • Bobier, W.R.1    Braddick, O.J.2
  • 4
    • 0034303871 scopus 로고    scopus 로고
    • Laboratory, clinical, and kindergarten test of a new eccentric infrared photorefractor (PowerRefractor)
    • Choi, M., Weiss, S., Schaeffel, F., Seidemann, A., Howland, H. C., Wilhelm, B. and Wilhelm, H. (2000) Laboratory, clinical, and kindergarten test of a new eccentric infrared photorefractor (PowerRefractor). Optom. Vis. Sci. 77, 537-548.
    • (2000) Optom. Vis. Sci. , vol.77 , pp. 537-548
    • Choi, M.1    Weiss, S.2    Schaeffel, F.3    Seidemann, A.4    Howland, H.C.5    Wilhelm, B.6    Wilhelm, H.7
  • 5
    • 0021861352 scopus 로고
    • Optics of photoretinoscopy: Results from ray tracing
    • Howland, H. C. (1985) Optics of photoretinoscopy: results from ray tracing. Am. J. Optom. Physiol. Opt. 62, 621-625.
    • (1985) Am. J. Optom. Physiol. Opt. , vol.62 , pp. 621-625
    • Howland, H.C.1
  • 6
    • 0348147570 scopus 로고    scopus 로고
    • Evaluation of the measurement of refractive error by the PowerRefractor: A remote, continuous and binocular measurement system of oculomotor function
    • Hunt, O. A., Wolffsohn, J. S. and Gilmartin, B. (2003) Evaluation of the measurement of refractive error by the PowerRefractor: a remote, continuous and binocular measurement system of oculomotor function. Br. J. Ophthalmol. 87, 1504-1508.
    • (2003) Br. J. Ophthalmol. , vol.87 , pp. 1504-1508
    • Hunt, O.A.1    Wolffsohn, J.S.2    Gilmartin, B.3
  • 8
    • 0022356835 scopus 로고
    • Clinical evaluation of the Canon Autoref R-1
    • McBrien, N. A. and Millodot, M. (1985) Clinical evaluation of the Canon Autoref R-1. Am. J. Optom. Optics 62, 786-792.
    • (1985) Am. J. Optom. Optics , vol.62 , pp. 786-792
    • McBrien, N.A.1    Millodot, M.2
  • 9
    • 0027461182 scopus 로고
    • Interindividual variability in the dynamics of natural accommodation in humans: Relation to age and refractive errors
    • Schaeffel, F., Wilhelm, H. and Zrenner, E. (1993) Interindividual variability in the dynamics of natural accommodation in humans: relation to age and refractive errors. J. Physiol. (London) 461, 301-320.
    • (1993) J. Physiol. (London) , vol.461 , pp. 301-320
    • Schaeffel, F.1    Wilhelm, H.2    Zrenner, E.3
  • 10
    • 0037302638 scopus 로고    scopus 로고
    • An evaluation of the lag of accommodation using photorefraction
    • Seidemann, A. and Schaeffel, F. (2003) An evaluation of the lag of accommodation using photorefraction. Vision. Res. 43, 419-430.
    • (2003) Vision. Res. , vol.43 , pp. 419-430
    • Seidemann, A.1    Schaeffel, F.2
  • 11
    • 0036885150 scopus 로고    scopus 로고
    • Peripheral refractive errors in myopic, emmetropic, and hyperopic young subjects
    • Seidemann, A., Schaeffel, F., Guirao, A., Lopez-Gil, N. and Artal, P. (2002) Peripheral refractive errors in myopic, emmetropic, and hyperopic young subjects. J. Opt. Soc. Am. 19, 2363-2373.
    • (2002) J. Opt. Soc. Am. , vol.19 , pp. 2363-2373
    • Seidemann, A.1    Schaeffel, F.2    Guirao, A.3    Lopez-Gil, N.4    Artal, P.5
  • 12
    • 0042662578 scopus 로고    scopus 로고
    • The manifestation of noncycloplegic refractive state in preschool children is dependant on autorefractor design
    • Suryakumar, R. and Bobier, W. R. (2003) The manifestation of noncycloplegic refractive state in preschool children is dependant on autorefractor design. Optom. Vis. Sci. 80, 578-586.
    • (2003) Optom. Vis. Sci. , vol.80 , pp. 578-586
    • Suryakumar, R.1    Bobier, W.R.2
  • 14
    • 0036729202 scopus 로고    scopus 로고
    • Continuous measurement of accommodation in human factor applications
    • Wolffsohn, J. S., Hunt, O. A. and Gilmartin, B. (2002) Continuous measurement of accommodation in human factor applications. Ophthal. Physiol. Opt. 22, 380-384.
    • (2002) Ophthal. Physiol. Opt. , vol.22 , pp. 380-384
    • Wolffsohn, J.S.1    Hunt, O.A.2    Gilmartin, B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.