메뉴 건너뛰기




Volumn 15, Issue 1, 2004, Pages 12-17

The sliding hip screw

Author keywords

Dynamic hip screw; Hip fracture; Intertrochanteric fracture; Sliding hip screw; Tip apex distance

Indexed keywords

BONE SCREW; FEMUR INTERTROCHANTERIC FRACTURE; HUMAN; PRIORITY JOURNAL; REVIEW; SLIDING HIP SCREW; SURGICAL TECHNIQUE;

EID: 1642498293     PISSN: 10419918     EISSN: None     Source Type: Journal    
DOI: 10.1097/00001433-200402000-00005     Document Type: Review
Times cited : (9)

References (55)
  • 1
    • 0000776951 scopus 로고    scopus 로고
    • A new principle in the operative treatment of trochanteric fractures of the femur
    • 195537A
    • Schumpelick W, Jantzen PM: A new principle in the operative treatment of trochanteric fractures of the femur. J Bone Joint Surg Am 195537A: 693-698.
    • J Bone Joint Surg Am , pp. 693-698
    • Schumpelick, W.1    Jantzen, P.M.2
  • 2
    • 0032905152 scopus 로고    scopus 로고
    • Fixed nail plates versus sliding hip systems for the treatment of trochanteric femoral fractures: A meta analysis of 14 studies
    • Chinoy MA, Parker MJ: Fixed nail plates versus sliding hip systems for the treatment of trochanteric femoral fractures: a meta analysis of 14 studies. Injury 1999, 30:157-163.
    • (1999) Injury , vol.30 , pp. 157-163
    • Chinoy, M.A.1    Parker, M.J.2
  • 3
    • 0034207605 scopus 로고    scopus 로고
    • Intertrochanteric-subtrochanteric fractures: Treatment with the long Gamma nail
    • Barquet A, Francescoli L, Rienzi D, et al.: Intertrochanteric- subtrochanteric fractures: treatment with the long Gamma nail. J Orthop Trauma 2000, 14:324-328.
    • (2000) J Orthop Trauma , vol.14 , pp. 324-328
    • Barquet, A.1    Francescoli, L.2    Rienzi, D.3
  • 4
    • 17144467492 scopus 로고    scopus 로고
    • Reverse obliquity fractures of the intertrochanteric region of the femur
    • Haidukewych GJ, Israel TA, Berry DJ: Reverse obliquity fractures of the intertrochanteric region of the femur. J Bone Joint Surg Am 2001, 83A:643-650.
    • (2001) J Bone Joint Surg Am , vol.83 A , pp. 643-650
    • Haidukewych, G.J.1    Israel, T.A.2    Berry, D.J.3
  • 5
    • 0036512930 scopus 로고    scopus 로고
    • Treatment of reverse oblique and transverse intertrochanteric fractures with use of an intramedullary nail or a 95 degrees screw-plate: A prospective, randomized study
    • Sadowski C, Lubbeke A, Saudan M, et al.: Treatment of reverse oblique and transverse intertrochanteric fractures with use of an intramedullary nail or a 95 degrees screw-plate: a prospective, randomized study. J Bone Joint Surg Am 2002, 84A:372-381.
    • (2002) J Bone Joint Surg Am , vol.84 A , pp. 372-381
    • Sadowski, C.1    Lubbeke, A.2    Saudan, M.3
  • 6
    • 0020626145 scopus 로고
    • Treatment of subtrochanteric fractures with a high-angle compression hip screw
    • Wile PB, Panjabi MM, Southwick WO: Treatment of subtrochanteric fractures with a high-angle compression hip screw. Clin Orthop 1983, May:72-78.
    • (1983) Clin Orthop , vol.MAY , pp. 72-78
    • Wile, P.B.1    Panjabi, M.M.2    Southwick, W.O.3
  • 7
    • 0019164767 scopus 로고
    • Biomechanical analysis of the sliding characteristics of compression hip screws
    • Kyle RF, Wright TM, Burstein AH: Biomechanical analysis of the sliding characteristics of compression hip screws. J Bone Joint Surg Am 1980, 62:1308-1314.
    • (1980) J Bone Joint Surg Am , vol.62 , pp. 1308-1314
    • Kyle, R.F.1    Wright, T.M.2    Burstein, A.H.3
  • 8
    • 0025139977 scopus 로고
    • A biomechanical analysis of the sliding hip screw: The question of plate angle
    • Meislin RJ, Zuckerman JD, Kummer FJ, et al.: A biomechanical analysis of the sliding hip screw: the question of plate angle. J Orthop Trauma 1990, 4:130-136.
    • (1990) J Orthop Trauma , vol.4 , pp. 130-136
    • Meislin, R.J.1    Zuckerman, J.D.2    Kummer, F.J.3
  • 9
    • 0027349743 scopus 로고
    • Sliding characteristics of compression hip screws in the intertrochanteric fracture: A clinical study
    • Yoshimine F, Latta LL, Milne EL: Sliding characteristics of compression hip screws in the intertrochanteric fracture: a clinical study. J Orthop Trauma 1993, 7:348-353.
    • (1993) J Orthop Trauma , vol.7 , pp. 348-353
    • Yoshimine, F.1    Latta, L.L.2    Milne, E.L.3
  • 10
    • 0030344529 scopus 로고    scopus 로고
    • Weight bearing after hip fracture: A prospective series of 596 geriatric hip fracture patients
    • Koval KJ, Friend KD, Aharonoff GB, et al.: Weight bearing after hip fracture: a prospective series of 596 geriatric hip fracture patients. J Orthop Trauma 1996, 10:526-530.
    • (1996) J Orthop Trauma , vol.10 , pp. 526-530
    • Koval, K.J.1    Friend, K.D.2    Aharonoff, G.B.3
  • 11
    • 0031923801 scopus 로고    scopus 로고
    • Postoperative weight-bearing after a fracture of the femoral neck or an intertrochanteric fracture
    • Koval KJ, Sala DA, Kummer FJ, et al.: Postoperative weight-bearing after a fracture of the femoral neck or an intertrochanteric fracture. J Bone Joint Surg Am 1998, 80:352-356.
    • (1998) J Bone Joint Surg Am , vol.80 , pp. 352-356
    • Koval, K.J.1    Sala, D.A.2    Kummer, F.J.3
  • 12
    • 0018861236 scopus 로고
    • Mechanics of the treatment of hip injuries
    • Kaufer H: Mechanics of the treatment of hip injuries. Clin Orthop 1980, Jan-Feb:53-61.
    • (1980) Clin Orthop , vol.JAN-FEB , pp. 53-61
    • Kaufer, H.1
  • 13
    • 0027582580 scopus 로고
    • Technical pitfalls in the use of the sliding hip screw for fixation of intertrochanteric hip fractures
    • Rokito AS, Koval KJ, Zuckerman JD: Technical pitfalls in the use of the sliding hip screw for fixation of intertrochanteric hip fractures. Contemp Orthop 1993, 26:349-356.
    • (1993) Contemp Orthop , vol.26 , pp. 349-356
    • Rokito, A.S.1    Koval, K.J.2    Zuckerman, J.D.3
  • 14
    • 0020076988 scopus 로고
    • Treatment of intertrochanteric fracture of the femur using sliding screw plate fixation
    • Wolfgang GL, Bryant MH, O'Neill JP: Treatment of intertrochanteric fracture of the femur using sliding screw plate fixation. Clin Orthop 1982, 14:148-158.
    • (1982) Clin Orthop , vol.14 , pp. 148-158
    • Wolfgang, G.L.1    Bryant, M.H.2    O'Neill, J.P.3
  • 15
    • 0021559797 scopus 로고
    • Fixation of intertrochanteric hip fractures with sliding devices
    • Kyle RF: Fixation of intertrochanteric hip fractures with sliding devices. Instr Course Lect 1984, 33:197-203.
    • (1984) Instr Course Lect , vol.33 , pp. 197-203
    • Kyle, R.F.1
  • 16
    • 0029012764 scopus 로고
    • The value of the tip-apex distance in predicting failure of fixation of peritrochanteric fractures of the hip
    • Baumgaertner MR, Curtin SL, Lindskog DM, et al.: The value of the tip-apex distance in predicting failure of fixation of peritrochanteric fractures of the hip. J Bone Joint Surg Am 1995, 77:1058-1064.
    • (1995) J Bone Joint Surg Am , vol.77 , pp. 1058-1064
    • Baumgaertner, M.R.1    Curtin, S.L.2    Lindskog, D.M.3
  • 17
    • 0030720275 scopus 로고    scopus 로고
    • Awareness of tip-apex distance reduces failure of fixation of trochanteric fractures of the hip
    • Baumgaertner MR, Solberg BD: Awareness of tip-apex distance reduces failure of fixation of trochanteric fractures of the hip. J Bone Joint Surg Br 1997, 79:969-971.
    • (1997) J Bone Joint Surg Br , vol.79 , pp. 969-971
    • Baumgaertner, M.R.1    Solberg, B.D.2
  • 18
    • 0035203607 scopus 로고    scopus 로고
    • Prospective randomized controlled trial of an intramedullary nail versus dynamic screw and plate for intertrochanteric fractures of the femur
    • Adams CI, Robinson CM, Court-Brown CM, et al.: Prospective randomized controlled trial of an intramedullary nail versus dynamic screw and plate for intertrochanteric fractures of the femur. J Orthop Trauma 2001, 15:394-400.
    • (2001) J Orthop Trauma , vol.15 , pp. 394-400
    • Adams, C.I.1    Robinson, C.M.2    Court-Brown, C.M.3
  • 19
    • 0027943425 scopus 로고
    • Basicervical fractures of the proximal femur: A biomechanical study of 3 internal fixation techniques
    • Blair B, Koval KJ, Kummer F, et al.: Basicervical fractures of the proximal femur: a biomechanical study of 3 internal fixation techniques. Clin Orthop 1994, 19:256-263.
    • (1994) Clin Orthop , vol.19 , pp. 256-263
    • Blair, B.1    Koval, K.J.2    Kummer, F.3
  • 20
    • 0033750496 scopus 로고    scopus 로고
    • Dynamic hip screw: Does side make a difference? Effects of clockwise torque on right and left DHS
    • Mohan R, Karthikeyan R, Sonanis SV: Dynamic hip screw: does side make a difference? Effects of clockwise torque on right and left DHS. Injury 2000, 31:697-699.
    • (2000) Injury , vol.31 , pp. 697-699
    • Mohan, R.1    Karthikeyan, R.2    Sonanis, S.V.3
  • 21
    • 0031132737 scopus 로고    scopus 로고
    • Optimal side plate fixation for unstable intertrochanteric hip fractures
    • Yian EH, Banerji I, Matthews LS: Optimal side plate fixation for unstable intertrochanteric hip fractures. J Orthop Trauma 1997, 11:254-259.
    • (1997) J Orthop Trauma , vol.11 , pp. 254-259
    • Yian, E.H.1    Banerji, I.2    Matthews, L.S.3
  • 22
    • 0034207664 scopus 로고    scopus 로고
    • Biomechanical evaluation of the dynamic hip screw with two- and four-hole side plates
    • McLoughlin SW, Wheeler DL, Rider J, et al.: Biomechanical evaluation of the dynamic hip screw with two-and four-hole side plates. J Orthop Trauma 2000, 14:318-323.
    • (2000) J Orthop Trauma , vol.14 , pp. 318-323
    • McLoughlin, S.W.1    Wheeler, D.L.2    Rider, J.3
  • 23
    • 0032608253 scopus 로고    scopus 로고
    • Results of intertrochanteric femur fractures treated with a 135-degree sliding screw with a two-hole side plate
    • Bolhofner BR, Russo PR, Carmen B: Results of intertrochanteric femur fractures treated with a 135-degree sliding screw with a two-hole side plate. J Orthop Trauma 1999, 13:5-8.
    • (1999) J Orthop Trauma , vol.13 , pp. 5-8
    • Bolhofner, B.R.1    Russo, P.R.2    Carmen, B.3
  • 25
    • 0031183549 scopus 로고    scopus 로고
    • Biomechanical comparison of internal fixation techniques for the treatment of unstable basicervical femoral neck fractures
    • Deneka DA, Simonian PT, Stankewich CJ, et al.: Biomechanical comparison of internal fixation techniques for the treatment of unstable basicervical femoral neck fractures. J Orthop Trauma 1997, 11:337-343.
    • (1997) J Orthop Trauma , vol.11 , pp. 337-343
    • Deneka, D.A.1    Simonian, P.T.2    Stankewich, C.J.3
  • 26
    • 0019305579 scopus 로고
    • The sliding compression screw: Today's best answer for stabilization of intertrochanteric hip fractures
    • Doppelt SH: The sliding compression screw: today's best answer for stabilization of intertrochanteric hip fractures. Orthop Clin North Am 1980, 11:507-523.
    • (1980) Orthop Clin North Am , vol.11 , pp. 507-523
    • Doppelt, S.H.1
  • 27
    • 0036982102 scopus 로고    scopus 로고
    • Extramedullary fixation implants for extracapsular hip fractures
    • CD000339
    • Parker MJ, Handoll HH: Extramedullary fixation implants for extracapsular hip fractures. Cochrane Database Syst Rev 2002, CD000339. A thorough meta-analysis of the extracapsular hip fracture literature that attempts to identify statistically significant factors affecting patient outcomes.
    • (2002) Cochrane Database Syst Rev
    • Parker, M.J.1    Handoll, H.H.2
  • 28
    • 0036177813 scopus 로고    scopus 로고
    • Intramedullary hip screw versus sliding hip screw for unstable intertrochanteric femoral fractures in the elderly
    • Harrington P, Nihal A, Singhania AK, et al.: Intramedullary hip screw versus sliding hip screw for unstable intertrochanteric femoral fractures in the elderly. Injury 2002, 33:23-28.
    • (2002) Injury , vol.33 , pp. 23-28
    • Harrington, P.1    Nihal, A.2    Singhania, A.K.3
  • 29
    • 0025131003 scopus 로고
    • Trochanteric fractures: Influence of reduction and implant position on impaction and complications
    • Larsson S, Friberg S, Hansson LI: Trochanteric fractures: influence of reduction and implant position on impaction and complications. Clin Orthop 1990, Oct:130-139.
    • (1990) Clin Orthop , vol.OCT , pp. 130-139
    • Larsson, S.1    Friberg, S.2    Hansson, L.I.3
  • 30
    • 0036064177 scopus 로고    scopus 로고
    • Pertrochanteric fractures: Is there an advantage to an intramedullary nail? A randomized, prospective study of 206 patients comparing the dynamic hip screw and proximal femoral nail
    • Saudan M, Lubbeke A, Sadowski C, et al.: Pertrochanteric fractures: is there an advantage to an intramedullary nail? A randomized, prospective study of 206 patients comparing the dynamic hip screw and proximal femoral nail. J Orthop Trauma 2002, 16:386-393.
    • (2002) J Orthop Trauma , vol.16 , pp. 386-393
    • Saudan, M.1    Lubbeke, A.2    Sadowski, C.3
  • 31
    • 0036331275 scopus 로고    scopus 로고
    • A randomized study of the compression hip screw and Gamma nail in 426 fractures
    • Ahrengart L, Tornkvist H, Fornander P, et al.: A randomized study of the compression hip screw and Gamma nail in 426 fractures. Clin Orthop 2002, Aug:209-222.
    • (2002) Clin Orthop , vol.AUG , pp. 209-222
    • Ahrengart, L.1    Tornkvist, H.2    Fornander, P.3
  • 32
    • 0031924186 scopus 로고    scopus 로고
    • Intramedullary versus extramedullary fixation for the treatment of intertrochanteric hip fractures
    • Baumgaertner MR, Curtin SL, Lindskog DM: Intramedullary versus extramedullary fixation for the treatment of intertrochanteric hip fractures. Clin Orthop 1998, Mar:87-94.
    • (1998) Clin Orthop , vol.MAR , pp. 87-94
    • Baumgaertner, M.R.1    Curtin, S.L.2    Lindskog, D.M.3
  • 33
    • 0031808886 scopus 로고    scopus 로고
    • Use of an intramedullary hip-screw compared with a compression hip-screw with a plate for intertrochanteric femoral fractures: A prospective, randomized study of one hundred patients
    • Hardy DC, Descamps PY, Krallis P, et al.: Use of an intramedullary hip-screw compared with a compression hip-screw with a plate for intertrochanteric femoral fractures: a prospective, randomized study of one hundred patients. J Bone Joint Surg Am 1998, 80:618-630.
    • (1998) J Bone Joint Surg Am , vol.80 , pp. 618-630
    • Hardy, D.C.1    Descamps, P.Y.2    Krallis, P.3
  • 34
    • 0031866341 scopus 로고    scopus 로고
    • Treatment of intertrochanteric fracture with the Gamma AP locking nail or by a compression hip screw: A randomised prospective trial
    • Park SR, Kang JS, Kim HS, et al.: Treatment of intertrochanteric fracture with the Gamma AP locking nail or by a compression hip screw: a randomised prospective trial. Int Orthop 1998, 22:157-160.
    • (1998) Int Orthop , vol.22 , pp. 157-160
    • Park, S.R.1    Kang, J.S.2    Kim, H.S.3
  • 35
    • 0033962288 scopus 로고    scopus 로고
    • Comparison of ender nails, dynamic hip screws, and Gamma nails in the treatment of peritrochanteric femoral fractures
    • Habernek H, Wallner T, Aschauer E, et al. Comparison of ender nails, dynamic hip screws, and Gamma nails in the treatment of peritrochanteric femoral fractures. Orthopedics 2000, 23:121-127.
    • (2000) Orthopedics , vol.23 , pp. 121-127
    • Habernek, H.1    Wallner, T.2    Aschauer, E.3
  • 36
    • 0035203345 scopus 로고    scopus 로고
    • Prospective randomized comparison between a dynamic hip screw and a mini-invasive static nail in fractures of the trochanteric area: Preliminary results
    • Dujardin FH, Benez C, Polle G, et al.: Prospective randomized comparison between a dynamic hip screw and a mini-invasive static nail in fractures of the trochanteric area: preliminary results. J Orthop Trauma 2001, 15:401-406.
    • (2001) J Orthop Trauma , vol.15 , pp. 401-406
    • Dujardin, F.H.1    Benez, C.2    Polle, G.3
  • 37
    • 0036635307 scopus 로고    scopus 로고
    • Implant-related fractures of the femur following hip fracture surgery
    • Robinson CM, Adams CI, Craig M, et al.: Implant-related fractures of the femur following hip fracture surgery. J Bone Joint Surg Am 2002, 84:1116-1122. A prospective study examining the incidence of implant-related fractures in patients with intra-and extracapsular hip fractures. Implants included the SHS and side plate, the intramedullary hip screw, parallel screws, cementless hemiarthroplasty, cemented hemiarthroplasty, and total hip arthroplasty. The relative risk of implant-related fracture was increased in the intramedullary hip screw and cementless hemiarthroplasty groups.
    • (2002) J Bone Joint Surg Am , vol.84 , pp. 1116-1122
    • Robinson, C.M.1    Adams, C.I.2    Craig, M.3
  • 38
    • 0033972149 scopus 로고    scopus 로고
    • Biomechanical analysis of the Medoff sliding plate
    • Mahomed MN, Harrington IJ, Hearn TC: Biomechanical analysis of the Medoff sliding plate. J Trauma 2000, 48:93-100.
    • (2000) J Trauma , vol.48 , pp. 93-100
    • Mahomed, M.N.1    Harrington, I.J.2    Hearn, T.C.3
  • 39
    • 0031872488 scopus 로고    scopus 로고
    • The Medoff sliding plate and a standard sliding hip screw for unstable intertrochanteric fractures: A mechanical comparison in cadaver femurs
    • Olsson O, Kummer FJ, Ceder L, et al.: The Medoff sliding plate and a standard sliding hip screw for unstable intertrochanteric fractures: a mechanical comparison in cadaver femurs. Acta Orthop Scand 1998, 69:266-272.
    • (1998) Acta Orthop Scand , vol.69 , pp. 266-272
    • Olsson, O.1    Kummer, F.J.2    Ceder, L.3
  • 40
    • 0031113827 scopus 로고    scopus 로고
    • Use of the Medoff sliding plate for subtrochanteric hip fractures
    • Kummer FJ, Pearlman CA, Koval KJ, et al.: Use of the Medoff sliding plate for subtrochanteric hip fractures. J Orthop Trauma 1997, 11:180-182.
    • (1997) J Orthop Trauma , vol.11 , pp. 180-182
    • Kummer, F.J.1    Pearlman, C.A.2    Koval, K.J.3
  • 41
    • 17744389598 scopus 로고    scopus 로고
    • Extramedullary fixation of 569 unstable intertrochanteric fractures: A randomized multicenter trial of the Medoff sliding plate versus three other screw-plate systems
    • Lunsjo K, Ceder L, Thorngren KG, et al.: Extramedullary fixation of 569 unstable intertrochanteric fractures: a randomized multicenter trial of the Medoff sliding plate versus three other screw-plate systems. Acta Orthop Scand 2001, 72:133-140.
    • (2001) Acta Orthop Scand , vol.72 , pp. 133-140
    • Lunsjo, K.1    Ceder, L.2    Thorngren, K.G.3
  • 42
    • 0034991415 scopus 로고    scopus 로고
    • Femoral shortening in intertrochanteric fractures: A comparison between the Medoff sliding plate and the compression hip screw
    • Olsson O, Ceder L, Hauggaard A: Femoral shortening in intertrochanteric fractures: a comparison between the Medoff sliding plate and the compression hip screw. J Bone Joint Surg Br 2001, 83:572-578.
    • (2001) J Bone Joint Surg Br , vol.83 , pp. 572-578
    • Olsson, O.1    Ceder, L.2    Hauggaard, A.3
  • 43
    • 0031924068 scopus 로고    scopus 로고
    • Comparison of the compression hip screw with the Medoff sliding plate for intertrochanteric fractures
    • Watson JT, Moed BR, Cramer KE, et al.: Comparison of the compression hip screw with the Medoff sliding plate for intertrochanteric fractures. Clin Orthop 1998, Mar:79-86.
    • (1998) Clin Orthop , vol.MAR , pp. 79-86
    • Watson, J.T.1    Moed, B.R.2    Cramer, K.E.3
  • 44
    • 0032134683 scopus 로고    scopus 로고
    • Clinical results using the trochanter stabilizing plate (TSP): The modular extension of the dynamic hip screw (DHS) for internal fixation of selected unstable intertrochanteric fractures
    • Babst R, Renner N, Biedermann M, et al.: Clinical results using the trochanter stabilizing plate (TSP): the modular extension of the dynamic hip screw (DHS) for internal fixation of selected unstable intertrochanteric fractures. J Orthop Trauma 1998, 12:392-399.
    • (1998) J Orthop Trauma , vol.12 , pp. 392-399
    • Babst, R.1    Renner, N.2    Biedermann, M.3
  • 45
    • 0032059914 scopus 로고    scopus 로고
    • Dynamic hip screw with trochanteric stabilizing plate in the treatment of unstable proximal femoral fractures: A comparative study with the Gamma nail and compression hip screw
    • Madsen JE, Naess L, Aune AK, et al.: Dynamic hip screw with trochanteric stabilizing plate in the treatment of unstable proximal femoral fractures: a comparative study with the Gamma nail and compression hip screw. J Orthop Trauma 1998, 12:241-248.
    • (1998) J Orthop Trauma , vol.12 , pp. 241-248
    • Madsen, J.E.1    Naess, L.2    Aune, A.K.3
  • 46
    • 0036298615 scopus 로고    scopus 로고
    • Percutaneous compression plating (PCCP) versus the dynamic hip screw for pertrochanteric hip fractures: Preliminary results
    • Brandt SE, Lefever S, Janzing HM, et al.: Percutaneous compression plating (PCCP) versus the dynamic hip screw for pertrochanteric hip fractures: preliminary results. Injury 2002, 33:413-418.
    • (2002) Injury , vol.33 , pp. 413-418
    • Brandt, S.E.1    Lefever, S.2    Janzing, H.M.3
  • 47
    • 0036151151 scopus 로고    scopus 로고
    • The Gotfried percutaneous compression plate compared with the conventional classic hip screw for the fixation of intertrochanteric fractures of the hip
    • Kosygan KP, Mohan R, Newman RJ: The Gotfried percutaneous compression plate compared with the conventional classic hip screw for the fixation of intertrochanteric fractures of the hip. J Bone Joint Surg Br 2002, 84:19-22.
    • (2002) J Bone Joint Surg Br , vol.84 , pp. 19-22
    • Kosygan, K.P.1    Mohan, R.2    Newman, R.J.3
  • 48
    • 0033638349 scopus 로고    scopus 로고
    • Extracapsular hip fractures: Fixation with a twin hook or a lag screw?
    • Olsson O, Ceder L, Lunsjo K, et al.: Extracapsular hip fractures: fixation with a twin hook or a lag screw? Int Orthop 2000, 24:249-255.
    • (2000) Int Orthop , vol.24 , pp. 249-255
    • Olsson, O.1    Ceder, L.2    Lunsjo, K.3
  • 49
    • 0036615711 scopus 로고    scopus 로고
    • Compression hip screw nail-plate system for intertrochanteric fractures
    • Maniscalco P, Rivera F, Bertone C, et al.: Compression hip screw nail-plate system for intertrochanteric fractures. Panminerva Med 2002, 44:135-139.
    • (2002) Panminerva Med , vol.44 , pp. 135-139
    • Maniscalco, P.1    Rivera, F.2    Bertone, C.3
  • 50
    • 0033644024 scopus 로고    scopus 로고
    • Robotic-assisted internal fixation of hip fractures: A fluoroscopy-based intraoperative registration technique
    • Browbank I, Bouazza-Marouf K, Schnabler J: Robotic-assisted internal fixation of hip fractures: a fluoroscopy-based intraoperative registration technique. Proc Inst Mech Eng [H] 2000, 214:165-179.
    • (2000) Proc Inst Mech Eng [H] , vol.214 , pp. 165-179
    • Browbank, I.1    Bouazza-Marouf, K.2    Schnabler, J.3
  • 51
    • 12244308512 scopus 로고    scopus 로고
    • Validation of fluoroscopy-based navigation in the hip region: What you see is what you get?
    • Schep NW, van Walsum T, De Graaf JS, et al.: Validation of fluoroscopy-based navigation in the hip region: what you see is what you get? Comput Aided Surg 2002, 7:279-283.
    • (2002) Comput Aided Surg , vol.7 , pp. 279-283
    • Schep, N.W.1    Van Walsum, T.2    De Graaf, J.S.3
  • 52
    • 0036096934 scopus 로고    scopus 로고
    • A modified hip screw incorporating injected cement for the fixation of osteoporotic trochanteric fractures
    • Augat P, Rapp S, Claes L: A modified hip screw incorporating injected cement for the fixation of osteoporotic trochanteric fractures. J Orthop Trauma 2002, 16:311-316.
    • (2002) J Orthop Trauma , vol.16 , pp. 311-316
    • Augat, P.1    Rapp, S.2    Claes, L.3
  • 53
    • 0036714410 scopus 로고    scopus 로고
    • A biomechanical analysis of fixation of intra-articular distal radial fractures with calcium-phosphate bone cement
    • Higgins TF, Dodds SD, Wolfe SW: A biomechanical analysis of fixation of intra-articular distal radial fractures with calcium-phosphate bone cement. J Bone Joint Surg Am 2002, 84A:1579-1586.
    • (2002) J Bone Joint Surg Am , vol.84 A , pp. 1579-1586
    • Higgins, T.F.1    Dodds, S.D.2    Wolfe, S.W.3
  • 54
    • 0031265179 scopus 로고    scopus 로고
    • Hip screw augmentation with an in situ-setting calcium phosphate cement: An in vitro biomechanical analysis
    • Moore DC, Frankenburg EP, Goulet JA, et al.: Hip screw augmentation with an in situ-setting calcium phosphate cement: an in vitro biomechanical analysis. J Orthop Trauma 1997, 11:577-583.
    • (1997) J Orthop Trauma , vol.11 , pp. 577-583
    • Moore, D.C.1    Frankenburg, E.P.2    Goulet, J.A.3
  • 55
    • 0031924185 scopus 로고    scopus 로고
    • Norian SRS cement augmentation in hip fracture treatment: Laboratory and initial clinical results
    • Goodman SB, Bauer TW, Carter D, et al.: Norian SRS cement augmentation in hip fracture treatment: laboratory and initial clinical results. Clin Orthop 1998, Mar:42-50.
    • (1998) Clin Orthop , vol.MAR , pp. 42-50
    • Goodman, S.B.1    Bauer, T.W.2    Carter, D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.