메뉴 건너뛰기




Volumn 14, Issue 5, 2000, Pages 324-328

Intertrochanteric-Subtrochanteric fractures: Treatment with the long Gamma nail

Author keywords

Intertrochanteric subtrochanteric fractures; Long gamma nail

Indexed keywords

ADOLESCENT; ADULT; AGED; ARTICLE; CLINICAL TRIAL; EVALUATION; FEMALE; FRACTURE HEALING; HIP FRACTURE; HUMAN; INSTRUMENTATION; INTRAMEDULLARY NAILING; MALE; MIDDLE AGED; MULTICENTER STUDY; PHYSIOLOGY; POSTOPERATIVE COMPLICATION; PROSPECTIVE STUDY; RADIOGRAPHY;

EID: 0034207605     PISSN: 08905339     EISSN: None     Source Type: Journal    
DOI: 10.1097/00005131-200006000-00003     Document Type: Article
Times cited : (97)

References (22)
  • 1
    • 0030064711 scopus 로고    scopus 로고
    • A locked hip screw-intramedullary nail (cephalomedullary nail) for the treatment of fractures of the proximal part of the femur combined with fractures of the femoral shaft
    • Alho A, Ekeland A, Grogaard B, Dokke JR. A locked hip screw-intramedullary nail (cephalomedullary nail) for the treatment of fractures of the proximal part of the femur combined with fractures of the femoral shaft. J Trauma 1996;40:10-16.
    • (1996) J Trauma , vol.40 , pp. 10-16
    • Alho, A.1    Ekeland, A.2    Grogaard, B.3    Dokke, J.R.4
  • 2
    • 85037509134 scopus 로고    scopus 로고
    • El clavo gamma en el tratamiento de las fracturas trocantéricas. Complicaciones y resultados
    • Barquet A. El clavo gamma en el tratamiento de las fracturas trocantéricas. Complicaciones y resultados [summary]. Rev Asoc Arg Ortop Traumatol 1996;61:214.
    • (1996) Rev Asoc Arg Ortop Traumatol , vol.61 , pp. 214
    • Barquet, A.1
  • 3
    • 0026555371 scopus 로고
    • A preliminary experience with the Russell-Taylor reconstruction nail for complex femoral fractures
    • Bose WJ, Corces A, Anderson LD. A preliminary experience with the Russell-Taylor reconstruction nail for complex femoral fractures. J Trauma 1992;32:71-76.
    • (1992) J Trauma , vol.32 , pp. 71-76
    • Bose, W.J.1    Corces, A.2    Anderson, L.D.3
  • 4
    • 0026288485 scopus 로고
    • Subtrochanteric femur fractures: A comparison of the Zickel nail, 95 blade plate, and interlocking nail
    • Brien W, Wiss D, Decher V, Lehman T. Subtrochanteric femur fractures: a comparison of the Zickel nail, 95 blade plate, and interlocking nail. J Orthop Trauma 1991;5:458-464.
    • (1991) J Orthop Trauma , vol.5 , pp. 458-464
    • Brien, W.1    Wiss, D.2    Decher, V.3    Lehman, T.4
  • 5
    • 0023557695 scopus 로고
    • Current status of locked intramedullary nailing: A review
    • Browner BD, Cole JD. Current status of locked intramedullary nailing: a review. J Orthop Trauma 1987;1:183-195.
    • (1987) J Orthop Trauma , vol.1 , pp. 183-195
    • Browner, B.D.1    Cole, J.D.2
  • 6
    • 0000094462 scopus 로고    scopus 로고
    • Fractures of the shaft of the femur
    • ed by Rockwood CA, Green DP, Bucholz RW, Heckman JD. Philadelphia, Lippincott-Raven
    • Bucholz RW, Brumback RJ. Fractures of the shaft of the femur. In: Fractures in Adults, 4th ed. ed by Rockwood CA, Green DP, Bucholz RW, Heckman JD. Philadelphia, Lippincott-Raven, 1996, pp 1827-1918.
    • (1996) Fractures in Adults, 4th Ed. , pp. 1827-1918
    • Bucholz, R.W.1    Brumback, R.J.2
  • 7
    • 0031263176 scopus 로고    scopus 로고
    • Functional recovery following hip fracture in the elderly
    • Egol KA, Koval KJ, Zuckerman JD. Functional recovery following hip fracture in the elderly. J Orthop Trauma 1997;11:594-599.
    • (1997) J Orthop Trauma , vol.11 , pp. 594-599
    • Egol, K.A.1    Koval, K.J.2    Zuckerman, J.D.3
  • 9
  • 10
    • 0026215816 scopus 로고
    • Initial experience with a second generation locking femoral nail: The Russell-Taylor reconstruction nail
    • Hoover GK, Browner BD, Cole JD, Comstock, Cotler HB. Initial experience with a second generation locking femoral nail: the Russell-Taylor reconstruction nail. Contemp Orthop 1991;23:199-208.
    • (1991) Contemp Orthop , vol.23 , pp. 199-208
    • Hoover, G.K.1    Browner, B.D.2    Cole, J.D.3    Cotler, H.B.4
  • 11
    • 0023682884 scopus 로고
    • Current techniques in the treatment of subtrochanteric fractures
    • Johnson KD. Current techniques in the treatment of subtrochanteric fractures. Tech Orthop 1988;3:14-24.
    • (1988) Tech Orthop , vol.3 , pp. 14-24
    • Johnson, K.D.1
  • 12
    • 0029446048 scopus 로고
    • The reconstruction locked nail for complex fractures of the proximal femur
    • Kang S, McAndrew MP, Johnson KD. The reconstruction locked nail for complex fractures of the proximal femur. J Orthop Trauma 1995;9:453-463.
    • (1995) J Orthop Trauma , vol.9 , pp. 453-463
    • Kang, S.1    McAndrew, M.P.2    Johnson, K.D.3
  • 13
    • 0000516167 scopus 로고
    • Outcomes research in orthopaedics
    • Keller RB. Outcomes research in orthopaedics. J Am Acad Orthop Surg 1993;1:122-129.
    • (1993) J Am Acad Orthop Surg , vol.1 , pp. 122-129
    • Keller, R.B.1
  • 14
    • 0031468135 scopus 로고    scopus 로고
    • Minimally invasive percutaneous plate osteosynthesis (MIPPO) using the DCS in proximal and distal femoral fractures
    • Krettek C, Schandelmaier P, Miclau T, Tscherne H. Minimally invasive percutaneous plate osteosynthesis (MIPPO) using the DCS in proximal and distal femoral fractures. Injury 1997; 28(Suppl 1):S-A20-S-A30.
    • (1997) Injury , vol.28 , Issue.1 SUPPL.
    • Krettek, C.1    Schandelmaier, P.2    Miclau, T.3    Tscherne, H.4
  • 15
    • 0024547454 scopus 로고
    • Subtrochanteric fractures of the femur: Results of treatment with the 95-degree condylar blade plate
    • Kinast C, Bolhofner BR, Mast JW, Ganz R. Subtrochanteric fractures of the femur: results of treatment with the 95-degree condylar blade plate. Clin Orthop 1989;238:122-130.
    • (1989) Clin Orthop , vol.238 , pp. 122-130
    • Kinast, C.1    Bolhofner, B.R.2    Mast, J.W.3    Ganz, R.4
  • 17
    • 85037517143 scopus 로고    scopus 로고
    • A comparison of 95 degree fixed angle plate devices to cephalomedullary nails in the treatment of high subtrochanteric femoral fractures
    • Louisville, Kentucky, October
    • Pistel W, Gregory P, DiPasquale T, Herscovici D, Sanders R. A comparison of 95 degree fixed angle plate devices to cephalomedullary nails in the treatment of high subtrochanteric femoral fractures. Paper presented at the Annual Meeting of the Orthopaedic Trauma Association, Louisville, Kentucky, October 1997.
    • (1997) Annual Meeting of the Orthopaedic Trauma Association
    • Pistel, W.1    Gregory, P.2    DiPasquale, T.3    Herscovici, D.4    Sanders, R.5
  • 18
    • 0005292483 scopus 로고    scopus 로고
    • Subtrochanteric fractures of the femur
    • ed by Browner BD, Jupiter JD, Levine AM, Trafton P. Philadelphia, WB Saunders
    • Russell TA, Taylor JC. Subtrochanteric fractures of the femur. In: Skeletal Trauma, ed by Browner BD, Jupiter JD, Levine AM, Trafton P. Philadelphia, WB Saunders, 1998, pp 1883-1925.
    • (1998) Skeletal Trauma , pp. 1883-1925
    • Russell, T.A.1    Taylor, J.C.2
  • 19
    • 0024367732 scopus 로고
    • Treatment of subtrochanteric fractures using the dynamic condylar screw
    • Sanders R, Regazzoni P. Treatment of subtrochanteric fractures using the dynamic condylar screw. J Orthop Trauma 1989;3:206-213.
    • (1989) J Orthop Trauma , vol.3 , pp. 206-213
    • Sanders, R.1    Regazzoni, P.2
  • 21
    • 0031469964 scopus 로고
    • Minimally invasive plate fixation in femoral shaft fractures
    • Wenda K, Runkel M, Degreif J, Rudig L. Minimally invasive plate fixation in femoral shaft fractures. Injury 1995;28(Suppl 1):S-A13-S-A19.
    • (1995) Injury , vol.28 , Issue.1 SUPPL.
    • Wenda, K.1    Runkel, M.2    Degreif, J.3    Rudig, L.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.