메뉴 건너뛰기




Volumn 32, Issue 4, 2005, Pages 273-278

Effects of cantilever design and material on stress distribution in fixed partial dentures - A finite element analysis

Author keywords

All ceramic; Distal cantilever; Finite element analysis; Fixed partial denture; Metal ceramic

Indexed keywords

ALLOY; CHROMIUM DERIVATIVE; LITHIUM DERIVATIVE; NICKEL COMPLEX; SILICATE;

EID: 16344389692     PISSN: 0305182X     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1365-2842.2004.01429.x     Document Type: Article
Times cited : (60)

References (35)
  • 3
    • 0031134265 scopus 로고    scopus 로고
    • Load factor control for implants in the posterior partially edentulous segment
    • Rangert B, Sullivan RM, Jemt TM. Load factor control for implants in the posterior partially edentulous segment. Int J Oral Maxillofac Imp. 1997;12:360-370.
    • (1997) Int J Oral Maxillofac Imp , vol.12 , pp. 360-370
    • Rangert, B.1    Sullivan, R.M.2    Jemt, T.M.3
  • 8
    • 0033139820 scopus 로고    scopus 로고
    • Periodontal response to cantilevered and fixed-fixed resin bonded bridges
    • al-Wahadni A, Linden GJ, Hussey DL. Periodontal response to cantilevered and fixed-fixed resin bonded bridges. Eur J Prosihodont Res Dent. 1999;7:57-60.
    • (1999) Eur J Prosihodont Res Dent , vol.7 , pp. 57-60
    • Wahadni, A.1    Linden, G.J.2    Hussey, D.L.3
  • 9
    • 0028390054 scopus 로고
    • Multivariate analyses of factors influencing the longevity of fixed partial dentures, retainers, and abutments
    • Palmqvist S, Söderfeldt B. Multivariate analyses of factors influencing the longevity of fixed partial dentures, retainers, and abutments. J Prosthet Dent. 1994;71:245-250.
    • (1994) J Prosthet Dent , vol.71 , pp. 245-250
    • Palmqvist, S.1    Söderfeldt, B.2
  • 10
    • 0020776467 scopus 로고
    • Biomechanical considerations in osseointegrated prostheses
    • Skalak R. Biomechanical considerations in osseointegrated prostheses. J Prosthet Dent. 1983;49:843-848.
    • (1983) J Prosthet Dent , vol.49 , pp. 843-848
    • Skalak, R.1
  • 11
    • 0030141120 scopus 로고    scopus 로고
    • Determination of cantilever length anterior-posterior spread assuming failure criteria to be the compromise of the prosthesis retaining screw-prosthesis joint
    • McAlarney ME, Stavropoulos DN. Determination of cantilever length anterior-posterior spread assuming failure criteria to be the compromise of the prosthesis retaining screw-prosthesis joint. Int J Oral Maxillofac Imp. 1996;11:331-339.
    • (1996) Int J Oral Maxillofac Imp , vol.11 , pp. 331-339
    • McAlarney, M.E.1    Stavropoulos, D.N.2
  • 12
    • 0031264312 scopus 로고    scopus 로고
    • A study of fixed prosthodontics performed at a university clinic 18 years after insertion
    • Sundh B, Odman P. A study of fixed prosthodontics performed at a university clinic 18 years after insertion. Int J Prosthodont. 1997;10:513-519.
    • (1997) Int J Prosthodont , vol.10 , pp. 513-519
    • Sundh, B.1    Odman, P.2
  • 13
    • 0032038092 scopus 로고    scopus 로고
    • A comparative evaluation of mandibular finite element models with different lengths and elements for implant biomechanics
    • Teixeira ER, Sato Y, Akagawa Y, Shindoi N. A comparative evaluation of mandibular finite element models with different lengths and elements for implant biomechanics. J Oral Rehabil. 1998;25:299-303.
    • (1998) J Oral Rehabil , vol.25 , pp. 299-303
    • Teixeira, E.R.1    Sato, Y.2    Akagawa, Y.3    Shindoi, N.4
  • 15
    • 0035377329 scopus 로고    scopus 로고
    • Application of finite element analysis in implant dentistry: A review of the literature
    • Geng JP, Tan KBC, Liu GR. Application of finite element analysis in implant dentistry: a review of the literature. J Prosthet Dent. 2001;85:585-598.
    • (2001) J Prosthet Dent , vol.85 , pp. 585-598
    • Geng, J.P.1    Tan, K.B.C.2    Liu, G.R.3
  • 16
    • 0031986671 scopus 로고    scopus 로고
    • Evaluating parameters of osseointegrated dental implants using finite element analysis - A two-dimensional comparative study examining the effects of implant diameter, implant shape, and load direction
    • Holmgren EP, Seckinger RJ, Kilgren LM, Mante F. Evaluating parameters of osseointegrated dental implants using finite element analysis - a two-dimensional comparative study examining the effects of implant diameter, implant shape, and load direction. J Oral Imp. 1998;24:80-88.
    • (1998) J Oral Imp , vol.24 , pp. 80-88
    • Holmgren, E.P.1    Seckinger, R.J.2    Kilgren, L.M.3    Mante, F.4
  • 17
    • 0030893518 scopus 로고    scopus 로고
    • Modeling the mechanical behavior of the jaws and their related structures by finite element (FE) analysis
    • Korioth TW, Versluis A. Modeling the mechanical behavior of the jaws and their related structures by finite element (FE) analysis. Crit Rev Oral Biol Med. 1997;8:90-104.
    • (1997) Crit Rev Oral Biol Med , vol.8 , pp. 90-104
    • Korioth, T.W.1    Versluis, A.2
  • 18
    • 0041153734 scopus 로고
    • Principal characteristics of the stress distribution in the jaw caused by dental implants
    • Huiskes R, Van Campen D, De Wijn J, eds. The Hague, The Netherlands: Martinus Nijhoff
    • Soltesz U, Siegele D. Principal characteristics of the stress distribution in the jaw caused by dental implants. In: Huiskes R, Van Campen D, De Wijn J, eds. Biomechanics: Principles and Applications. The Hague, The Netherlands: Martinus Nijhoff, 1982;439-444.
    • (1982) Biomechanics: Principles and Applications , pp. 439-444
    • Soltesz, U.1    Siegele, D.2
  • 19
    • 85016033318 scopus 로고
    • Mechanical loading of Brånemark implants affecting interfacial bone modeling and remodeling
    • Hoshaw SJ, Brunski JB, Cochran GVB. Mechanical loading of Brånemark implants affecting interfacial bone modeling and remodeling. Int J Oral Maxillofac Imp. 1994;9:345-360.
    • (1994) Int J Oral Maxillofac Imp , vol.9 , pp. 345-360
    • Hoshaw, S.J.1    Brunski, J.B.2    Cochran, G.V.B.3
  • 20
    • 0021131451 scopus 로고
    • Functional strain as a determinant for bone remodelling
    • Lanyon LE. Functional strain as a determinant for bone remodelling. Calcif Tissue Int. 1984;36:556-561.
    • (1984) Calcif Tissue Int , vol.36 , pp. 556-561
    • Lanyon, L.E.1
  • 21
    • 3643074502 scopus 로고    scopus 로고
    • Biomechanical aspects of prosthetic implant-bone reconstructions
    • Glantz P-O, Nilner K. Biomechanical aspects of prosthetic implant-bone reconstructions. Periodontology 2000. 1998;17:119-224.
    • (1998) Periodontology 2000 , vol.17 , pp. 119-224
    • Glantz, P.-O.1    Nilner, K.2
  • 22
    • 0036616546 scopus 로고    scopus 로고
    • Finite element analysis of forces created by root separation and resection modeling
    • Ünsal E, Eskitaşcioǧlu G, Soykan E, Walsh TF. Finite element analysis of forces created by root separation and resection modeling. J Oral Sci. 2002;44:79-84.
    • (2002) J Oral Sci , vol.44 , pp. 79-84
    • Ünsal, E.1    Eskitaşcioǧlu, G.2    Soykan, E.3    Walsh, T.F.4
  • 25
    • 1242312853 scopus 로고
    • Current evaluation of plastics in crown anterior bridge prosthesis
    • Peyton FA, Craig RG. Current evaluation of plastics in crown anterior bridge prosthesis. J Prosthet Dent. 1963;13:743-753.
    • (1963) J Prosthet Dent , vol.13 , pp. 743-753
    • Peyton, F.A.1    Craig, R.G.2
  • 26
    • 0023407994 scopus 로고
    • Stress distribution in metal-ceramic crowns with a facial porcelain margin
    • Anusavice KJ, Hojjatie B. Stress distribution in metal-ceramic crowns with a facial porcelain margin. J Dent Res. 1987;66:1493-1498.
    • (1987) J Dent Res , vol.66 , pp. 1493-1498
    • Anusavice, K.J.1    Hojjatie, B.2
  • 27
    • 0036728222 scopus 로고    scopus 로고
    • Evaluation of two post-core systems using two different methods (fracture strength test and a finite elemental stress analysis)
    • Eskitaşcioǧlu G, Kalkan M, Belli S. Evaluation of two post-core systems using two different methods (fracture strength test and a finite elemental stress analysis). J Endodon. 2002;28:629-633.
    • (2002) J Endodon , vol.28 , pp. 629-633
    • Eskitaşcioǧlu, G.1    Kalkan, M.2    Belli, S.3
  • 28
    • 0018993043 scopus 로고
    • Stress analysis of mandibular partial dentures with bounded and free-end saddles
    • MacGregor AR, Miller TP, Farah JW. Stress analysis of mandibular partial dentures with bounded and free-end saddles. J Dent. 1980;8:27-34.
    • (1980) J Dent , vol.8 , pp. 27-34
    • MacGregor, A.R.1    Miller, T.P.2    Farah, J.W.3
  • 29
    • 0024815560 scopus 로고
    • Finite element analysis of three- And four-unit bridges
    • Farah JW, Craig RG, Meroveh KA. Finite element analysis of three- and four-unit bridges. J Oral Rehabil. 1989;16:603-611.
    • (1989) J Oral Rehabil , vol.16 , pp. 603-611
    • Farah, J.W.1    Craig, R.G.2    Meroveh, K.A.3
  • 30
    • 0026892027 scopus 로고
    • Stress distribution around the dental implants. Influence of suprastructure, length of implants, and height of mandible
    • Meijer HJA, Kuiper JH, Starmans FJM, Bosman F. Stress distribution around the dental implants. Influence of suprastructure, length of implants, and height of mandible. J Prosthet Dent. 1992;68:96-102.
    • (1992) J Prosthet Dent , vol.68 , pp. 96-102
    • Meijer, H.J.A.1    Kuiper, J.H.2    Starmans, F.J.M.3    Bosman, F.4
  • 31
    • 0031267997 scopus 로고    scopus 로고
    • 3D- FEA of osseointegration percentages and patterns on implant bone interfacial stresses
    • Papavasiliou G, Kamposiora P, Bayne SC, Felton DA. 3D- FEA of osseointegration percentages and patterns on implant bone interfacial stresses. J Dent. 1997;25:485-491.
    • (1997) J Dent , vol.25 , pp. 485-491
    • Papavasiliou, G.1    Kamposiora, P.2    Bayne, S.C.3    Felton, D.A.4
  • 32
    • 0035464349 scopus 로고    scopus 로고
    • Finite element stress analysis of the influence of staggered versus straight placement of dental implants
    • Akça K, Iplikçioǧlu H. Finite element stress analysis of the influence of staggered versus straight placement of dental implants. Int J Oral Maxillofac Imp. 2001;16:722-730.
    • (2001) Int J Oral Maxillofac Imp , vol.16 , pp. 722-730
    • Akça, K.1    Iplikçioǧlu, H.2
  • 33
    • 0035378360 scopus 로고    scopus 로고
    • The effects of dowel design and load direction on dowel-and-core restorations
    • Yang HS, Lang LA, Molina A, Felton DA. The effects of dowel design and load direction on dowel-and-core restorations. J Prosthet Dent. 2001;85:558-567.
    • (2001) J Prosthet Dent , vol.85 , pp. 558-567
    • Yang, H.S.1    Lang, L.A.2    Molina, A.3    Felton, D.A.4
  • 35
    • 0028533833 scopus 로고
    • A finite element analysis of the human temporomandibular joint
    • Chen J, Xu L. A finite element analysis of the human temporomandibular joint. J Biomech Eng. 1994;116:401-407.
    • (1994) J Biomech Eng. , vol.116 , pp. 401-407
    • Chen, J.1    Xu, L.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.