-
2
-
-
0042345605
-
Technische komponenten
-
Semmler, W., Reiser, M. (Hrsg.). Springer Verlag, Berlin
-
Bock, M.: Technische Komponenten. In: Semmler, W., Reiser, M. (Hrsg.): Magnetresonanztomographie. Springer Verlag, Berlin 2002, 82-96
-
(2002)
Magnetresonanztomographie
, pp. 82-96
-
-
Bock, M.1
-
3
-
-
2442547244
-
MR-guided interventional procedures: Real-time parameter control and automated slice positioning with active tracking coils
-
Bock, M., Volz, S., Zühlsdorff, S., Umathum, R., Fink, C., Hallscheidt, P., Semmler, W.: MR-Guided Interventional Procedures: Real-Time Parameter Control and Automated Slice Positioning With Active Tracking Coils. J. Magn. Reson. Imag. 19 (2004) 580-589
-
(2004)
J. Magn. Reson. Imag.
, vol.19
, pp. 580-589
-
-
Bock, M.1
Volz, S.2
Zühlsdorff, S.3
Umathum, R.4
Fink, C.5
Hallscheidt, P.6
Semmler, W.7
-
4
-
-
0029781333
-
Tuned fiducial markers to identify body locations with minimal pertubation of tissue magnetization
-
Burl, M., Coutts, G. A., Young, I. R.: Tuned fiducial markers to identify body locations with minimal pertubation of tissue magnetization. Magn. Reson. Med. 36 (1996) 491-493
-
(1996)
Magn. Reson. Med.
, vol.36
, pp. 491-493
-
-
Burl, M.1
Coutts, G.A.2
Young, I.R.3
-
6
-
-
0031884958
-
Remember true FISP? A high SNR, near 1-second imaging method for T2-like contrast in interventional MRI at 2T
-
Duerck, J. L., Lewin, J., Wendt, M., Petersilge, C.: Remember true FISP? A high SNR, near 1-second imaging method for T2-like contrast in interventional MRI at 2T. J. Magn. Reson. Imag. 8 (1998) 203-208
-
(1998)
J. Magn. Reson. Imag.
, vol.8
, pp. 203-208
-
-
Duerck, J.L.1
Lewin, J.2
Wendt, M.3
Petersilge, C.4
-
7
-
-
0036139528
-
A brief review of hardware for catheter tracking in magnetic resonance imaging
-
Duerk, J. L., Wong, E. Y., Lewin, J. S.: A brief review of hardware for catheter tracking in magnetic resonance imaging. MAGMA 13 (2002) 199-208
-
(2002)
MAGMA
, vol.13
, pp. 199-208
-
-
Duerk, J.L.1
Wong, E.Y.2
Lewin, J.S.3
-
8
-
-
0027399141
-
Real-time position monitoring of invasive devices using magnetic resonance
-
Dumoulin, C.L., Souza, S.P., Darrow, R.D.: Real-time position monitoring of invasive devices using magnetic resonance. Magn. Reson. Med. 29 (1993) 411-415
-
(1993)
Magn. Reson. Med.
, vol.29
, pp. 411-415
-
-
Dumoulin, C.L.1
Souza, S.P.2
Darrow, R.D.3
-
9
-
-
0034759116
-
A method for fast 3D tracking using tuned fiducial markers and a limited projection reconstruction FISP (LPR-FISP) sequence
-
Flask, C., Elgort, D., Wong, E., Shankaranarayanan, A., Lewin, J., Wendt, M., Duerk, J. L.: A method for fast 3D tracking using tuned fiducial markers and a limited projection reconstruction FISP (LPR-FISP) sequence. J. Magn. Reson. Imag. 14 (2001) 617-627
-
(2001)
J. Magn. Reson. Imag.
, vol.14
, pp. 617-627
-
-
Flask, C.1
Elgort, D.2
Wong, E.3
Shankaranarayanan, A.4
Lewin, J.5
Wendt, M.6
Duerk, J.L.7
-
10
-
-
0038377168
-
Inductively coupled rf coils for examinations of small animals and objects in standard whole-body MR scanners
-
Graf, H., Martirosian, P., Schick, F., Grieser, M., Bellemann, M. E.: Inductively coupled rf coils for examinations of small animals and objects in standard whole-body MR scanners. Med. Phys. 30 (2003) 1241-1245
-
(2003)
Med. Phys.
, vol.30
, pp. 1241-1245
-
-
Graf, H.1
Martirosian, P.2
Schick, F.3
Grieser, M.4
Bellemann, M.E.5
-
11
-
-
0141726456
-
Active MRI catheters with integrated resonating circuit and RF antenna without lead connection to the MR system
-
Melzer, A., Busch, M.H., Bertsch, T., Wetzier, R., Toennissen, F.: Active MRI catheters with integrated resonating circuit and RF antenna without lead connection to the MR system. Radiology 217 (2000) 913
-
(2000)
Radiology
, vol.217
, pp. 913
-
-
Melzer, A.1
Busch, M.H.2
Bertsch, T.3
Wetzier, R.4
Toennissen, F.5
-
12
-
-
0035172358
-
On the heating of linear conductive structures as guide wires and catheters in interventional MRI
-
Nitz, W.R., Oppelt, A., Renz, W., Manke, C., Lenhart, M., Link, J.: On the heating of linear conductive structures as guide wires and catheters in interventional MRI. J. Magn. Reson. Imag 13 (2001) 105-114
-
(2001)
J. Magn. Reson. Imag.
, vol.13
, pp. 105-114
-
-
Nitz, W.R.1
Oppelt, A.2
Renz, W.3
Manke, C.4
Lenhart, M.5
Link, J.6
-
13
-
-
0036220776
-
Sicherheitsaspekte bei der interventionellen MRT
-
Oppelt, A., Delakis, I.: Sicherheitsaspekte bei der interventionellen MRT. Z. Med. Phys. 12 (2002) 5-15
-
(2002)
Z. Med. Phys.
, vol.12
, pp. 5-15
-
-
Oppelt, A.1
Delakis, I.2
-
14
-
-
0029848753
-
Two dimensional coronary MR angiography without breath holding
-
Oshinski, J.N, Hofland, L., Mukundan, S., Dixon, W.T., Parks, W.J., Pettigrew, R. I.: Two dimensional coronary MR angiography without breath holding. Radiology 201 (1996) 737-743
-
(1996)
Radiology
, vol.201
, pp. 737-743
-
-
Oshinski, J.N.1
Hofland, L.2
Mukundan, S.3
Dixon, W.T.4
Parks, W.J.5
Pettigrew, R.I.6
-
15
-
-
0001272938
-
Wireless implanted magnetic resonance probes for in vivo NMR
-
Schnall, M.D., Barlow, C., Subramanian, V.H., Leigh, J.S.: Wireless implanted magnetic resonance probes for in vivo NMR. J. Magn. Reson. 68 (1986) 161-167
-
(1986)
J. Magn. Reson.
, vol.68
, pp. 161-167
-
-
Schnall, M.D.1
Barlow, C.2
Subramanian, V.H.3
Leigh, J.S.4
-
16
-
-
0141726453
-
Automatic and interactive device tracking in interventional MR
-
Volz, S., Zuehlsdorff, S., Thesen, S., Meyer, H., Nitz, W., Umathum, R., Semmler, W., Bock, M.: Automatic and interactive device tracking in interventional MR. European Radiology 12 (2002) F29
-
(2002)
European Radiology
, vol.12
-
-
Volz, S.1
Zuehlsdorff, S.2
Thesen, S.3
Meyer, H.4
Nitz, W.5
Umathum, R.6
Semmler, W.7
Bock, M.8
-
17
-
-
0141447685
-
Ein verfahren zur sicheren visualisierung und lokalisierung von kathetern für MR-geführte intravaskuläre prozeduren
-
Weiss, S., Schaeffter, T., Brinkert, F., Kühne, T., Bücker, A.: Ein Verfahren zur sicheren Visualisierung und Lokalisierung von Kathetern für MR-geführte intravaskuläre Prozeduren. Z. Med. Phys. 13 (2003) 172-176
-
(2003)
Z. Med. Phys.
, vol.13
, pp. 172-176
-
-
Weiss, S.1
Schaeffter, T.2
Brinkert, F.3
Kühne, T.4
Bücker, A.5
-
18
-
-
0033819207
-
An optical system for wireless detuning of parallel resonant circuits
-
Wong, E. Y., Zhang, Q., Duerk, J. L., Lewin, J. S., Wendt, M.: An optical system for wireless detuning of parallel resonant circuits. Magn. Reson. Med. 12 (2000) 632-638
-
(2000)
Magn. Reson. Med.
, vol.12
, pp. 632-638
-
-
Wong, E.Y.1
Zhang, Q.2
Duerk, J.L.3
Lewin, J.S.4
Wendt, M.5
-
19
-
-
4243916982
-
Comparison of different steady state preparation techniques in tracking sequences
-
Zuehlsdorff, S., Volz, S., Semmler, W., Bock, M.: Comparison of different steady state preparation techniques in tracking sequences. European Radiology 12 (2002) F11
-
(2002)
European Radiology
, vol.12
-
-
Zuehlsdorff, S.1
Volz, S.2
Semmler, W.3
Bock, M.4
|