메뉴 건너뛰기




Volumn 109, Issue 1-2, 2005, Pages 49-63

Multidetector CT: A new gold standard in the diagnosis of pulmonary embolism? State of the art and diagnostic algorithms;La TC multidetettore: Il nuovo gold standard nella diagnosi di embolia polmonare? Stato dell'arte e algoritmi diagnostici

Author keywords

Computed tomography; Pulmonary embolism, diagnosis

Indexed keywords

ALGORITHM; CLINICAL TRIAL; HUMAN; LUNG EMBOLISM; MEDICAL LITERATURE; META ANALYSIS; MULTIDETECTOR COMPUTED TOMOGRAPHY; REVIEW; SENSITIVITY AND SPECIFICITY; SYSTEMATIC REVIEW; ARTICLE; COMPUTER ASSISTED TOMOGRAPHY; RADIATION DOSE; RADIOGRAPHY; SPIRAL COMPUTER ASSISTED TOMOGRAPHY;

EID: 16244372047     PISSN: 00338362     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Review
Times cited : (30)

References (54)
  • 1
    • 0037569374 scopus 로고    scopus 로고
    • Pulmonary embolus imaging with multislice CT
    • Review
    • Remy-Jardin M, Mastora I, Remy J: Pulmonary embolus imaging with multislice CT. Radiol Clin N Am 41: 507-519 Review, 2003.
    • (2003) Radiol Clin N Am , vol.41 , pp. 507-519
    • Remy-Jardin, M.1    Mastora, I.2    Remy, J.3
  • 2
    • 0037406918 scopus 로고    scopus 로고
    • Pulmonary embolism: Optimization of small pulmonary artery visualization at multi-detector row CT
    • Patel S, Kazerooni EA, Cascade PN: Pulmonary embolism: optimization of small pulmonary artery visualization at multi-detector row CT. Radiology 227: 455-460, 2003.
    • (2003) Radiology , vol.227 , pp. 455-460
    • Patel, S.1    Kazerooni, E.A.2    Cascade, P.N.3
  • 3
    • 0141796728 scopus 로고    scopus 로고
    • The evaluation of suspected pulmonary embolism
    • Fedullo PF, Tapson VF: The evaluation of suspected pulmonary embolism. N Engl J Med 349:1247-1256, 2003.
    • (2003) N Engl J Med , vol.349 , pp. 1247-1256
    • Fedullo, P.F.1    Tapson, V.F.2
  • 4
    • 0030760617 scopus 로고    scopus 로고
    • Treatment of patients with suspected pulmonary embolism and intermediate-probability lung scans: Is diagnostic imaging underused?
    • Khorasani R, Gudas TF, Nikpoor N, Polak JF: Treatment of patients with suspected pulmonary embolism and intermediate-probability lung scans: is diagnostic imaging underused? AJR 169:1355-1357, 1997.
    • (1997) AJR , vol.169 , pp. 1355-1357
    • Khorasani, R.1    Gudas, T.F.2    Nikpoor, N.3    Polak, J.F.4
  • 5
    • 23744465573 scopus 로고    scopus 로고
    • Clinical utilization of non diagnostic-lung scintigram
    • Murchison JT, Gavan DR, Reid JH: Clinical utilization of non diagnostic-lung scintigram. Clin Radiol 52:295-298, 1997.
    • (1997) Clin Radiol , vol.52 , pp. 295-298
    • Murchison, J.T.1    Gavan, D.R.2    Reid, J.H.3
  • 6
    • 0029026454 scopus 로고
    • Detection of pulmonary embolism in patients with unresolved clinical and scintigraphic diagnosis: Helical CT versus angiography
    • Goodman LR, Curtin JJ, Mewissen MW et al: Detection of pulmonary embolism in patients with unresolved clinical and scintigraphic diagnosis: helical CT versus angiography. AJR 164:1369-1374, 1995.
    • (1995) AJR , vol.164 , pp. 1369-1374
    • Goodman, L.R.1    Curtin, J.J.2    Mewissen, M.W.3
  • 7
    • 0033752851 scopus 로고    scopus 로고
    • Pulmonary embolism detection: Prospective evaluation of dual-section helical CT versus selective pulmonary arteriography in 157 patients
    • Qanadli SD, Hajjam ME, Mesurolle B et al: Pulmonary embolism detection: prospective evaluation of dual-section helical CT versus selective pulmonary arteriography in 157 patients. Radiology 217: 447-455, 2000.
    • (2000) Radiology , vol.217 , pp. 447-455
    • Qanadli, S.D.1    Hajjam, M.E.2    Mesurolle, B.3
  • 8
    • 0034327787 scopus 로고    scopus 로고
    • Multislice CT improves diagnosis, management of aortic disease
    • Rydberg J, Kopecky KK, Fleiter TR: Multislice CT improves diagnosis, management of aortic disease. Diagn Imaging 22: 159-163, 2000.
    • (2000) Diagn Imaging , vol.22 , pp. 159-163
    • Rydberg, J.1    Kopecky, K.K.2    Fleiter, T.R.3
  • 9
    • 0036153994 scopus 로고    scopus 로고
    • Subsegmental pulmonary emboli: Improved detection with thin-collimation multi-detector row spiral CT
    • Schoepf UJ, Holzknecht N, Helmberger TK et al: Subsegmental pulmonary emboli: improved detection with thin-collimation multi-detector row spiral CT. Radiology 222: 483-490, 2002.
    • (2002) Radiology , vol.222 , pp. 483-490
    • Schoepf, U.J.1    Holzknecht, N.2    Helmberger, T.K.3
  • 10
    • 0034999402 scopus 로고    scopus 로고
    • Peripheral pulmonary arteries: How far in the lung does multi-detector row spiral CT allow analysis?
    • Ghaye B, Szapiro D, Mastora Iet al: Peripheral pulmonary arteries: how far in the lung does multi-detector row spiral CT allow analysis? Radiology 219: 629-636, 2001.
    • (2001) Radiology , vol.219 , pp. 629-636
    • Ghaye, B.1    Szapiro, D.2    Mastora, I.3
  • 11
    • 0037929762 scopus 로고    scopus 로고
    • Comparison of doses for pulmonary embolism detection with helical CT and pulmonary angiography
    • Resten A, Mausoleo F, Valero M, Musset D: Comparison of doses for pulmonary embolism detection with helical CT and pulmonary angiography. Eur Radiol 13: 1515-1521, 2003.
    • (2003) Eur Radiol , vol.13 , pp. 1515-1521
    • Resten, A.1    Mausoleo, F.2    Valero, M.3    Musset, D.4
  • 12
    • 0037591933 scopus 로고    scopus 로고
    • Radiation exposure of multi-row detector spiral computed tomography of the pulmonary arteries: Comparison with digital subtraction pulmonary angiography
    • Kuiper JW, Geleijns J, Matheijssen NA et al: Radiation exposure of multi-row detector spiral computed tomography of the pulmonary arteries: comparison with digital subtraction pulmonary angiography. Eur Radiol 13: 1496-1500, 2003.
    • (2003) Eur Radiol , vol.13 , pp. 1496-1500
    • Kuiper, J.W.1    Geleijns, J.2    Matheijssen, N.A.3
  • 13
    • 0242268410 scopus 로고    scopus 로고
    • ECG-gated multislice spiral CT for diagnosis of acute pulmonary embolism
    • Marten K, Engelke C, Funke M et al: ECG-gated multislice spiral CT for diagnosis of acute pulmonary embolism. Clin Radiol 58: 862-868, 2003.
    • (2003) Clin Radiol , vol.58 , pp. 862-868
    • Marten, K.1    Engelke, C.2    Funke, M.3
  • 14
    • 84949123263 scopus 로고    scopus 로고
    • Combined diagnostic approach to venous thromboembolism with multidetector computed tomography
    • Greco F, Zanolini A, Bova C et al: Combined diagnostic approach to venous thromboembolism with multidetector computed tomography. Ital Heart J 4: 226-231, 2003.
    • (2003) Ital Heart J , vol.4 , pp. 226-231
    • Greco, F.1    Zanolini, A.2    Bova, C.3
  • 15
    • 0037780981 scopus 로고    scopus 로고
    • Multidetector-row CT imaging of pulmonary embolism
    • Schoepf UJ, Costello P: Multidetector-row CT imaging of pulmonary embolism. Sem Roentgenol 38: 106-114, 2003.
    • (2003) Sem Roentgenol , vol.38 , pp. 106-114
    • Schoepf, U.J.1    Costello, P.2
  • 16
    • 0035184558 scopus 로고    scopus 로고
    • Multidetector row spiral CT pulmonary angiography: Comparison with single-detector row spiral CT
    • Raptopoulos V, Boiselle PM: Multidetector row spiral CT pulmonary angiography: comparison with single-detector row spiral CT. Radiology 221:606-613, 2001.
    • (2001) Radiology , vol.221 , pp. 606-613
    • Raptopoulos, V.1    Boiselle, P.M.2
  • 18
    • 0034069213 scopus 로고    scopus 로고
    • Four multidetector row helical CT: Image quality and volume coverage speed
    • Hu H, He HD, Foley WD et al: Four multidetector row helical CT: image quality and volume coverage speed. Radiology 215: 55-62, 2000.
    • (2000) Radiology , vol.215 , pp. 55-62
    • Hu, H.1    He, H.D.2    Foley, W.D.3
  • 19
    • 0037725430 scopus 로고    scopus 로고
    • Images in clinical radiology. Diagnosis of pulmonary embolism with 16-slice CT
    • Salovic D, Humblet Y, Coche E: Images in clinical radiology. Diagnosis of pulmonary embolism with 16-slice CT. JBR-BTR 86:113, 2003.
    • (2003) JBR-BTR , vol.86 , pp. 113
    • Salovic, D.1    Humblet, Y.2    Coche, E.3
  • 20
    • 0037743441 scopus 로고    scopus 로고
    • Peripheral pulmonary arteries: Identification at multi-slice spiral CT with 3D reconstruction
    • Coche E, Pawlak S, Dechambre S, Maldague B: Peripheral pulmonary arteries: identification at multi-slice spiral CT with 3D reconstruction. Eur Radiol 13: 815-822, 2003.
    • (2003) Eur Radiol , vol.13 , pp. 815-822
    • Coche, E.1    Pawlak, S.2    Dechambre, S.3    Maldague, B.4
  • 21
    • 1642458217 scopus 로고    scopus 로고
    • CT angiography for diagnosis of pulmonary embolism: State of the art
    • Schoepf UJ, Costello P: CT angiography for diagnosis of pulmonary embolism: state of the art.. Radiology 230:329-337, 2004.
    • (2004) Radiology , vol.230 , pp. 329-337
    • Schoepf, U.J.1    Costello, P.2
  • 22
    • 2442568734 scopus 로고    scopus 로고
    • Spiral computed tomography for acute pulmonary embolism
    • Schoepf UJ, Goldhaber SZ, Costello P: Spiral computed tomography for acute pulmonary embolism. Circulation 109:2160-2167, 2004.
    • (2004) Circulation , vol.109 , pp. 2160-2167
    • Schoepf, U.J.1    Goldhaber, S.Z.2    Costello, P.3
  • 23
    • 0038471175 scopus 로고    scopus 로고
    • British Thoracic Society guidelines for the management of suspected acute pulmonary embolism
    • British Thoracic Society Standards of Care Committee Pulmonary Embolism Guideline Development Group: British Thoracic Society guidelines for the management of suspected acute pulmonary embolism. Thorax 58: 470-483, 2003.
    • (2003) Thorax , vol.58 , pp. 470-483
  • 24
    • 0036149805 scopus 로고    scopus 로고
    • Current strategies for the diagnosis of pulmonary embolus
    • Review
    • Johnson MS: Current strategies for the diagnosis of pulmonary embolus. Review. J Vasc Interv Radiol 13: 13-23, 2002.
    • (2002) J Vasc Interv Radiol , vol.13 , pp. 13-23
    • Johnson, M.S.1
  • 25
    • 0030711577 scopus 로고    scopus 로고
    • Pulmonary embolism: Prospective comparison of spiral CT with ventilation-perfusion scintigraphy
    • Mayo JR, Remy-Jardin M, Muller NL et al: Pulmonary embolism: prospective comparison of spiral CT with ventilation-perfusion scintigraphy. Radiology 205: 447-452, 1997.
    • (1997) Radiology , vol.205 , pp. 447-452
    • Mayo, J.R.1    Remy-Jardin, M.2    Muller, N.L.3
  • 26
    • 0031616247 scopus 로고    scopus 로고
    • Accuracy of helical CT for acute pulmonary embolism: ROC analysis of observer performance related to clinical experience
    • Van Rossum AB, van Erkel AR, van Persijn EL et al: Accuracy of helical CT for acute pulmonary embolism: ROC analysis of observer performance related to clinical experience. Eur Radiol 8: 1160-1164, 1998.
    • (1998) Eur Radiol , vol.8 , pp. 1160-1164
    • Van Rossum, A.B.1    Van Erkel, A.R.2    Van Persijn, E.L.3
  • 27
    • 0034068022 scopus 로고    scopus 로고
    • Spiral computed tomography is comparable to angiography for the diagnosis of pulmonary embolism
    • Baile EM, King GG, Muller NL et al: Spiral computed tomography is comparable to angiography for the diagnosis of pulmonary embolism. Am J Respir Crit Care Med 161:1010-1015, 2000.
    • (2000) Am J Respir Crit Care Med , vol.161 , pp. 1010-1015
    • Baile, E.M.1    King, G.G.2    Muller, N.L.3
  • 28
    • 0034127134 scopus 로고    scopus 로고
    • Pulmonary embolism revealed on helical CT angiography: Comparison with ventilation-perfusion radionuclide lung scanning
    • Blachere H, Latrabe V, Montaudon M et al: Pulmonary embolism revealed on helical CT angiography: comparison with ventilation-perfusion radionuclide lung scanning. AJR 174: 1041-1047, 2000.
    • (2000) AJR , vol.174 , pp. 1041-1047
    • Blachere, H.1    Latrabe, V.2    Montaudon, M.3
  • 29
    • 0037591923 scopus 로고    scopus 로고
    • Diagnosis of pulmonary embolism with spiral CT as a second procedure following scintigraphy
    • Van Strijen MJ, de Monye W, Kieft GJ et al: Diagnosis of pulmonary embolism with spiral CT as a second procedure following scintigraphy. Eur Radiol 13: 1501-1507, 2003.
    • (2003) Eur Radiol , vol.13 , pp. 1501-1507
    • Van Strijen, M.J.1    De Monye, W.2    Kieft, G.J.3
  • 30
    • 0037834399 scopus 로고    scopus 로고
    • CT detection of pulmonary embolism in a patient with negative pulmonary angiogram
    • Romano M. Mainenti PP, Imbriaco M et al: CT detection of pulmonary embolism in a patient with negative pulmonary angiogram. Radiol Med 105: 234-237, 2003.
    • (2003) Radiol Med , vol.105 , pp. 234-237
    • Romano, M.1    Mainenti, P.P.2    Imbriaco, M.3
  • 31
    • 0030716466 scopus 로고    scopus 로고
    • Acute pulmonary embolism: Role of helical CT in 164 patients with intermediate probability at ventilation-perfusion scintigraphy and normal results at duplex US of the legs
    • Ferretti GR, Bosson JL, Buffaz PD et al: Acute pulmonary embolism: role of helical CT in 164 patients with intermediate probability at ventilation-perfusion scintigraphy and normal results at duplex US of the legs. Radiology 205: 453-458, 1997.
    • (1997) Radiology , vol.205 , pp. 453-458
    • Ferretti, G.R.1    Bosson, J.L.2    Buffaz, P.D.3
  • 32
    • 0029959067 scopus 로고    scopus 로고
    • Pulmonary embolism: Validation of spiral CT angiography in 149 patients
    • Van Rossum AB, Pattynama PM, Ton ER et al: Pulmonary embolism: validation of spiral CT angiography in 149 patients. Radiology 201:467-470, 1996.
    • (1996) Radiology , vol.201 , pp. 467-470
    • Van Rossum, A.B.1    Pattynama, P.M.2    Ton, E.R.3
  • 33
    • 0029831577 scopus 로고    scopus 로고
    • Diagnosis of pulmonary embolism with spiral CT: Comparison with pulmonary angiography and scintigraphy
    • Remy-Jardin M, Remy J, Deschildre F et al: Diagnosis of pulmonary embolism with spiral CT: comparison with pulmonary angiography and scintigraphy. Radiology 200: 699-706, 1996.
    • (1996) Radiology , vol.200 , pp. 699-706
    • Remy-Jardin, M.1    Remy, J.2    Deschildre, F.3
  • 34
    • 0031010385 scopus 로고    scopus 로고
    • Peripheral pulmonary arteries: Optimization of the spiral CT acquisition protocol
    • Remy-Jardin M, Remy J, Artaud D et al: Peripheral pulmonary arteries: optimization of the spiral CT acquisition protocol. Radiology 204:157-163, 1997.
    • (1997) Radiology , vol.204 , pp. 157-163
    • Remy-Jardin, M.1    Remy, J.2    Artaud, D.3
  • 35
    • 0031878546 scopus 로고    scopus 로고
    • Pulmonary embolism: Diagnosis with spiral CT and ventilation-perfusion scanning-correlation with pulmonary angiographic results or clinical outcome
    • Garg K, Welsh CH, Feyerabend AJ et al: Pulmonary embolism: diagnosis with spiral CT and ventilation-perfusion scanning-correlation with pulmonary angiographic results or clinical outcome. Radiology 208: 2081-2088, 1998.
    • (1998) Radiology , vol.208 , pp. 2081-2088
    • Garg, K.1    Welsh, C.H.2    Feyerabend, A.J.3
  • 36
    • 0345129978 scopus 로고    scopus 로고
    • Clinically suspected pulmonary embolism: Utility of spiral CT
    • Kim KI, Muller NL, Mayo JR: Clinically suspected pulmonary embolism: utility of spiral CT. Radiology 210: 693-697, 1999.
    • (1999) Radiology , vol.210 , pp. 693-697
    • Kim, K.I.1    Muller, N.L.2    Mayo, J.R.3
  • 37
    • 0033770568 scopus 로고    scopus 로고
    • Accuracy of CT angiography in the diagnosis of acute pulmonary embolism: Evaluation of literature with summary ROC curve analysis
    • Harvey RT, Gefter WB, Hrung JM, Langlotz CP: Accuracy of CT angiography in the diagnosis of acute pulmonary embolism: evaluation of literature with summary ROC curve analysis. Acad Radiol 7: 786-797, 2000.
    • (2000) Acad Radiol , vol.7 , pp. 786-797
    • Harvey, R.T.1    Gefter, W.B.2    Hrung, J.M.3    Langlotz, C.P.4
  • 38
    • 0031691222 scopus 로고    scopus 로고
    • Rapid D-dimer assays to exclude deep venous thrombosis and pulmonary embolism: Current status and new developments
    • Janssen MC, Wollersheim H, Verbruggen B, Novakova IR: Rapid D-dimer assays to exclude deep venous thrombosis and pulmonary embolism: current status and new developments. Review Semin Thromb Hemost, 24: 393-400, 1998.
    • (1998) Review Semin Thromb Hemost , vol.24 , pp. 393-400
    • Janssen, M.C.1    Wollersheim, H.2    Verbruggen, B.3    Novakova, I.R.4
  • 39
    • 12244264850 scopus 로고    scopus 로고
    • A comparison of spiral computed tomography and latex agglutination D-dimer assay in acute pulmonary embolism using pulmonary arteriography as gold standard
    • Nilsson T, Soderberg M, Lundqvist G et al: A comparison of spiral computed tomography and latex agglutination D-dimer assay in acute pulmonary embolism using pulmonary arteriography as gold standard. Scand Cardiovasc J 36: 373-377, 2002.
    • (2002) Scand Cardiovasc J , vol.36 , pp. 373-377
    • Nilsson, T.1    Soderberg, M.2    Lundqvist, G.3
  • 40
    • 0037107264 scopus 로고    scopus 로고
    • The performance of two rapid quantitative D-dimer assays in 287 patients with clinically suspected pulmonary embolism
    • ANTELOPE Study Group
    • de Monye W, Sanson BJ, Buller HR: ANTELOPE Study Group. The performance of two rapid quantitative D-dimer assays in 287 patients with clinically suspected pulmonary embolism. Thromb Res 107: 283-286, 2002.
    • (2002) Thromb Res , vol.107 , pp. 283-286
    • De Monye, W.1    Sanson, B.J.2    Buller, H.R.3
  • 41
    • 0242331112 scopus 로고    scopus 로고
    • Turbidimetric D-dimer test in the diagnosis of pulmonary embolism: A metaanalysis
    • Brown MD, Lau J, Nelson RD, Kline JA: Turbidimetric D-dimer test in the diagnosis of pulmonary embolism: a metaanalysis. Clin Chem. 49: 1846-1853, 2003.
    • (2003) Clin Chem , vol.49 , pp. 1846-1853
    • Brown, M.D.1    Lau, J.2    Nelson, R.D.3    Kline, J.A.4
  • 42
    • 0032726308 scopus 로고    scopus 로고
    • Initial treatment of venous thromboembolism
    • Review
    • Kearon C: Initial treatment of venous thromboembolism. Review Thromb Haemost. 82: 887-891, 1999.
    • (1999) Thromb Haemost , vol.82 , pp. 887-891
    • Kearon, C.1
  • 43
    • 0037404746 scopus 로고    scopus 로고
    • Sonography and venography of the lower extremities for diagnosing deep vein thrombosis in symptomatic patients
    • Theodorou SJ, Theodorou DJ, Kakitsubata Y: Sonography and venography of the lower extremities for diagnosing deep vein thrombosis in symptomatic patients. Clin Imaging 27: 180-183, 2003.
    • (2003) Clin Imaging , vol.27 , pp. 180-183
    • Theodorou, S.J.1    Theodorou, D.J.2    Kakitsubata, Y.3
  • 44
    • 0025354523 scopus 로고
    • Value of the ventilation/perfusion scan in acute pulmonary embolism. Results of the Prospective Investigation of Pulmonary Embolism Diagnosis (PIOPED)
    • The PIOPED Investigators: Value of the ventilation/perfusion scan in acute pulmonary embolism. Results of the Prospective Investigation Of Pulmonary Embolism Diagnosis (PIOPED). JAMA 263:2753-2759, 1990.
    • (1990) JAMA , vol.263 , pp. 2753-2759
  • 45
    • 0030939253 scopus 로고    scopus 로고
    • Diagnosis of pulmonary embolism with magnetic resonance angiography
    • Meaney JF, Weg JG, Chenevert TL et al: Diagnosis of pulmonary embolism with magnetic resonance angiography. N Engl J Med. 336: 1422-1427, 1997.
    • (1997) N Engl J Med , vol.336 , pp. 1422-1427
    • Meaney, J.F.1    Weg, J.G.2    Chenevert, T.L.3
  • 46
    • 0032927120 scopus 로고    scopus 로고
    • Acute pulmonary embolism: Diagnosis with MR angiography
    • Gupta A, Frazer CK, Ferguson JM et al: Acute pulmonary embolism: diagnosis with MR angiography. Radiology 210:353-359, 1999.
    • (1999) Radiology , vol.210 , pp. 353-359
    • Gupta, A.1    Frazer, C.K.2    Ferguson, J.M.3
  • 47
    • 0036187987 scopus 로고    scopus 로고
    • Combined MR proton lung perfusion/angiography and helium ventilation: Potential for detecting pulmonary emboli and ventilation defects
    • Zheng J, Leawoods JC, Nolte M et al: Combined MR proton lung perfusion/angiography and helium ventilation: potential for detecting pulmonary emboli and ventilation defects. Magn Reson Med 47:433-438, 2002.
    • (2002) Magn Reson Med , vol.47 , pp. 433-438
    • Zheng, J.1    Leawoods, J.C.2    Nolte, M.3
  • 48
    • 0018952126 scopus 로고
    • The incidence, etiologies, and avoidance of complications of pulmonary angiography in a large series
    • Mills SR, Jackson DC, Older RA et al: The incidence, etiologies, and avoidance of complications of pulmonary angiography in a large series. Radiology 136: 295-299, 1980.
    • (1980) Radiology , vol.136 , pp. 295-299
    • Mills, S.R.1    Jackson, D.C.2    Older, R.A.3
  • 49
    • 0026515509 scopus 로고
    • Complications and validity of pulmonary angiography in acute pulmonary embolism
    • Stein PD, Athanasoulis C, Alavi A et al: Complications and validity of pulmonary angiography in acute pulmonary embolism. Circulation 85: 462-468, 1992.
    • (1992) Circulation , vol.85 , pp. 462-468
    • Stein, P.D.1    Athanasoulis, C.2    Alavi, A.3
  • 50
    • 0031655371 scopus 로고    scopus 로고
    • Effect of anatomic distribution of pulmonary embolism interobserver agreement in the interpretation of pulmonary angiography
    • Diffin DC, Leyendecker JR, Johnson SP et al: Effect of anatomic distribution of pulmonary embolism interobserver agreement in the interpretation of pulmonary angiography. AJR 171: 1085-1089, 1998.
    • (1998) AJR , vol.171 , pp. 1085-1089
    • Diffin, D.C.1    Leyendecker, J.R.2    Johnson, S.P.3
  • 51
    • 0033015757 scopus 로고    scopus 로고
    • Reassessment of pulmonary angiography for the diagnosis of pulmonary embolism: Relation of interpreter agreement to the order of the involved pulmonary arterial branch
    • Stein PD, Henry JW, Gottschalk A: Reassessment of pulmonary angiography for the diagnosis of pulmonary embolism: relation of interpreter agreement to the order of the involved pulmonary arterial branch. Radiology 210: 689-691, 1999.
    • (1999) Radiology , vol.210 , pp. 689-691
    • Stein, P.D.1    Henry, J.W.2    Gottschalk, A.3
  • 52
    • 0037591921 scopus 로고    scopus 로고
    • Severity assessment of acute pulmonary embolism: Evaluation using helical CT
    • Collomb D, Paramelle PJ, Calaque O et al: Severity assessment of acute pulmonary embolism: evaluation using helical CT. Eur Radiol. 13: 1508-1514, 2003.
    • (2003) Eur Radiol , vol.13 , pp. 1508-1514
    • Collomb, D.1    Paramelle, P.J.2    Calaque, O.3
  • 53
    • 0038576102 scopus 로고    scopus 로고
    • Severity of acute pulmonary embolism: Evaluation of a new spiral CT angiographic score in correlation with echocardiographic data
    • Mastora I, Remy-Jardin M, Masson P et al: Severity of acute pulmonary embolism: evaluation of a new spiral CT angiographic score in correlation with echocardiographic data. Eur Radiol 13:29-35, 2003.
    • (2003) Eur Radiol , vol.13 , pp. 29-35
    • Mastora, I.1    Remy-Jardin, M.2    Masson, P.3
  • 54
    • 0142241248 scopus 로고    scopus 로고
    • Helical CT pulmonary angiography predictors of in-hospital morbidity and mortality in patients with acute pulmonary embolism
    • Araoz PA, Gotway MB, Trowbridge RL et al: Helical CT pulmonary angiography predictors of in-hospital morbidity and mortality in patients with acute pulmonary embolism. J Thorac Imaging 18: 207-216, 2003.
    • (2003) J Thorac Imaging , vol.18 , pp. 207-216
    • Araoz, P.A.1    Gotway, M.B.2    Trowbridge, R.L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.