Automatic geometrical calibration for X-ray microtomography based on Fourier and Radon analysis

Author keywords

Alignment; Fourier analysis; Microtomography; Radon transform; Synchrotron radiation; X ray tomography

Indexed keywords

ALIGNMENT; COMPUTATIONAL GEOMETRY; COMPUTERIZED TOMOGRAPHY; FOURIER TRANSFORMS; IMAGE RECONSTRUCTION; OSCILLATIONS; PARAMETER ESTIMATION; SYNCHROTRON RADIATION;

EID: 15844398617     PISSN: 0277786X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.557094     Document Type: Conference Paper
Times cited : (7)

References (7)
  • 1
    • 0031802790 scopus 로고    scopus 로고
    • Evaluation of imaging geometries calculated from biplane images
    • J. Esthappan, H. Harauchi, and K. R. Hoffmann, "Evaluation of imaging geometries calculated from biplane images," Med. Phys. 25, pp. 965-975, 1998.
    • (1998) Med. Phys. , vol.25 , pp. 965-975
    • Esthappan, J.1    Harauchi, H.2    Hoffmann, K.R.3
  • 2
    • 0033781494 scopus 로고    scopus 로고
    • Analytic method based on identification of ellipse parameters for scanner calibration in cone-beam tomography
    • F. Noo, R. Clackdoyle, C. Mennessier, T. A. White, and T. J. Roney, "Analytic method based on identification of ellipse parameters for scanner calibration in cone-beam tomography," Phys. Med. Biol. 45, pp. 3489-3508, 2000.
    • (2000) Phys. Med. Biol. , vol.45 , pp. 3489-3508
    • Noo, F.1    Clackdoyle, R.2    Mennessier, C.3    White, T.A.4    Roney, T.J.5
  • 3
    • 0001085542 scopus 로고    scopus 로고
    • Computed tomography of cryogenic biological specimens based on X-ray microscopic images
    • D. Weiss, G. Schneider, B. Niemann, P. Guttmann, D. Rudolph, and G. Schmahl, "Computed tomography of cryogenic biological specimens based on X-ray microscopic images," Ultramicroscopy 84, pp. 185-197, 2000.
    • (2000) Ultramicroscopy , vol.84 , pp. 185-197
    • Weiss, D.1    Schneider, G.2    Niemann, B.3    Guttmann, P.4    Rudolph, D.5    Schmahl, G.6
  • 4
    • 0034764479 scopus 로고    scopus 로고
    • Implementation of a cone-beam reconstruction algorithm for the single-circle source orbit with embedded misalignment correction using homogeneous coordinates
    • M. Karolczak, S. Scahller, K. Engelke, A. Lutz, U. Taubenreuther, K. Wiesent, and W. Kalender, "Implementation of a cone-beam reconstruction algorithm for the single-circle source orbit with embedded misalignment correction using homogeneous coordinates," Med. Phys. 28, pp. 2050-2069, 2001.
    • (2001) Med. Phys. , vol.28 , pp. 2050-2069
    • Karolczak, M.1    Scahller, S.2    Engelke, K.3    Lutz, A.4    Taubenreuther, U.5    Wiesent, K.6    Kalender, W.7
  • 5
    • 0001091515 scopus 로고    scopus 로고
    • Virtual alignment of x-ray cone-beam tomography system using two calibration aperture measurements
    • A. V. Bronnikov, "Virtual alignment of x-ray cone-beam tomography system using two calibration aperture measurements," Opt. Eng. 38, pp. 381-386, 1999.
    • (1999) Opt. Eng. , vol.38 , pp. 381-386
    • Bronnikov, A.V.1
  • 7
    • 15844373305 scopus 로고    scopus 로고
    • P. Bleuet and T. Weitkamp, to be published
    • P. Bleuet and T. Weitkamp, to be published.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.