메뉴 건너뛰기




Volumn 61, Issue 6, 2003, Pages 713-718

Evaluation of a new heterogeneous immunoassay for the whole-blood determination of cyclosporin on the dade Behring dimension RXL clinical chemistry analyzer;Évaluation du réactif immunologique hété rogène (ACMIA) pour le dosage sanguin de ciclosporine sur RXL HM Dimension®

Author keywords

Cyclosporin monitoring; Heterogeneous immunoassay; Immunosuppressive drug; RXL HM Dimension

Indexed keywords

CYCLOSPORIN;

EID: 1542609839     PISSN: 00033898     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (1)

References (11)
  • 1
    • 0028846198 scopus 로고
    • Challenges in cyclosporine therapy: The role of therapeutic monitoring by area under the curve monitoring
    • Kahan BD, Welsh M, Rutzky LP. Challenges in cyclosporine therapy: the role of therapeutic monitoring by area under the curve monitoring. Ther Drug Monit 1995 ; 17 : 621-4.
    • (1995) Ther Drug Monit , vol.17 , pp. 621-624
    • Kahan, B.D.1    Welsh, M.2    Rutzky, L.P.3
  • 2
    • 0034119511 scopus 로고    scopus 로고
    • Methods for clinical monitoring of cyclosporin in transplant patients
    • Dumont RJ, Ensom MHH. Methods for clinical monitoring of cyclosporin in transplant patients. Clin Pharmacokinet 2000 ; 38 ; 427-47.
    • (2000) Clin Pharmacokinet , vol.38 , pp. 427-447
    • Dumont, R.J.1    Ensom, M.H.H.2
  • 3
    • 0024589575 scopus 로고
    • Cyclosporine monitoring in renal transplantation: Area under the curve monitoring is superior to trough-level monitoring
    • Grevel J, Welsh M, Kahan BD. Cyclosporine monitoring in renal transplantation: area under the curve monitoring is superior to trough-level monitoring. Ther Drug Monit 1989 ; 11 : 246-8.
    • (1989) Ther Drug Monit , vol.11 , pp. 246-248
    • Grevel, J.1    Welsh, M.2    Kahan, B.D.3
  • 4
    • 0025793712 scopus 로고
    • Area under the curve monitoring of cyclosporine therapy: The early posttransplant period
    • Grevel J, Kahan BD. Area under the curve monitoring of cyclosporine therapy: the early posttransplant period. Ther Drug Monit 1991 ; 13 : 89-95.
    • (1991) Ther Drug Monit , vol.13 , pp. 89-95
    • Grevel, J.1    Kahan, B.D.2
  • 5
    • 0033492458 scopus 로고    scopus 로고
    • Evaluation of four automated methods for determination of whole blood cyclosporine concentrations
    • Hamwi A, Veitl M, Manner G, Ruzicka K, Schweiger C, Szekeres T. Evaluation of four automated methods for determination of whole blood cyclosporine concentrations. Am J Clin Pathol 1999 ; 112 : 358-65.
    • (1999) Am J Clin Pathol , vol.112 , pp. 358-365
    • Hamwi, A.1    Veitl, M.2    Manner, G.3    Ruzicka, K.4    Schweiger, C.5    Szekeres, T.6
  • 6
    • 0034046768 scopus 로고    scopus 로고
    • New approaches to cyclosporine monitoring raise further concerns about analytical techniques
    • Holt DW, Johnston A, Kahan BD, Morris RG, Oellerich M, Shaw LM. New approaches to cyclosporine monitoring raise further concerns about analytical techniques. Clin Chem 2000 ; 46 : 872-4.
    • (2000) Clin Chem , vol.46 , pp. 872-874
    • Holt, D.W.1    Johnston, A.2    Kahan, B.D.3    Morris, R.G.4    Oellerich, M.5    Shaw, L.M.6
  • 7
    • 0030915574 scopus 로고    scopus 로고
    • Whole blood cyclosporin monitoring in liver and heart transplant patients: Evaluation of the specificity of a fluorescence polarization immunoassay and an enzyme-multiplied immunoassay technique
    • Gulbis B, Van der Heijden J, Van As H, Thiry P. Whole blood cyclosporin monitoring in liver and heart transplant patients: evaluation of the specificity of a fluorescence polarization immunoassay and an enzyme-multiplied immunoassay technique. J Pharm Biomed Anal 1997 ; 15 : 957-63.
    • (1997) J Pharm Biomed Anal , vol.15 , pp. 957-963
    • Gulbis, B.1    Van Der Heijden, J.2    Van As, H.3    Thiry, P.4
  • 8
    • 0344673013 scopus 로고    scopus 로고
    • Procédure de validation d'une technique
    • Vassault A. Procédure de validation d'une technique. Spectra Biologie 1997 ; 16 : 43-50.
    • (1997) Spectra Biologie , vol.16 , pp. 43-50
    • Vassault, A.1
  • 9
    • 0034425004 scopus 로고    scopus 로고
    • Cyclosporine metabolism in patients after kidney, bone marrow, heart-lung, and liver transplantation in the early and late posttransplant periods
    • Hamwi A, Salomon A, Steinbrugger R, Fritzer-Szekeres M, Jager W, Szekeres T. Cyclosporine metabolism in patients after kidney, bone marrow, heart-lung, and liver transplantation in the early and late posttransplant periods. Am J Clin Pathol 2000 ; 114 : 536-43.
    • (2000) Am J Clin Pathol , vol.114 , pp. 536-543
    • Hamwi, A.1    Salomon, A.2    Steinbrugger, R.3    Fritzer-Szekeres, M.4    Jager, W.5    Szekeres, T.6
  • 10
    • 0031909930 scopus 로고    scopus 로고
    • Pharmacodynamic monitoring of immunosuppressive drugs
    • Yatscoff RW, Aspeslet LJ, Gallant HL. Pharmacodynamic monitoring of immunosuppressive drugs. Clin Chem 1998 ; 44 : 428-32.
    • (1998) Clin Chem , vol.44 , pp. 428-432
    • Yatscoff, R.W.1    Aspeslet, L.J.2    Gallant, H.L.3
  • 11
    • 18444406859 scopus 로고    scopus 로고
    • Evaluation of a no-pretreatment cyclosporin A assay on the Dade Behring dimension RxL clinchemistry analyzer
    • Terrell AR, Daly TM, Hock KG, et al. Evaluation of a no-pretreatment cyclosporin A assay on the Dade Behring dimension RxL clinchemistry analyzer. Clin Chem 2002 ; 48 : 1059-65.
    • (2002) Clin Chem , vol.48 , pp. 1059-1065
    • Terrell, A.R.1    Daly, T.M.2    Hock, K.G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.