Volumn 19, Issue 11 II, 1996, Pages 1672-1677

Comparison of continuously recorded sensor and sinus rates during daily life activities and standardized exercise testing: Efficacy of automatically optimized rate adaptive dual sensor pacing to simulate sinus rhythm

Author keywords

automaticity; dual sensors; programming

Indexed keywords

ADULT; AGED; ARTICLE; ARTIFICIAL HEART PACEMAKER; CHRONOTROPISM; CLINICAL ARTICLE; CLINICAL PROTOCOL; COMPLETE HEART BLOCK; COMPUTER PROGRAM; CONTROLLED STUDY; DAILY LIFE ACTIVITY; EXERCISE TEST; FEMALE; HUMAN; MALE; SENSOR; SINUS RHYTHM; TREADMILL EXERCISE; WORKLOAD;

EID: 0029993815     PISSN: 01478389     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1540-8159.1996.tb03204.x     Document Type: Article
Times cited : (27)

References (11)
  • 1
    • 0026670863 scopus 로고
    • The range of sensors and algorithms used in rate adaptive cardiac pacing
    • Lau CP. The range of sensors and algorithms used in rate adaptive cardiac pacing (review). PACE 1992; 15:1177-1211.
    • (1992) PACE , vol.15 , pp. 1177-1211
    • Lau, C.P.1
  • 2
    • 0027294026 scopus 로고
    • Initial experience with a new single sensor dual sensor rate responsive pacemaker
    • Connell DT and the Topaz Study Group. Initial experience with a new single sensor dual sensor rate responsive pacemaker. PACE 1993; 16: 1833-41.
    • (1993) PACE , vol.16 , pp. 1833-1841
    • Connell, D.T.1
  • 3
    • 0028913001 scopus 로고
    • Evaluation of a new rate adaptive ventricular pacemaker controlled by double sensors
    • Ovsyshcher I, Guldal M, Karazguz R, et al. Evaluation of a new rate adaptive ventricular pacemaker controlled by double sensors. PACE 1995; 18: 386-400.
    • (1995) PACE , vol.18 , pp. 386-400
    • Ovsyshcher, I.1    Guldal, M.2    Karazguz, R.3
  • 4
    • 0026498860 scopus 로고
    • Clinical results of automatic slope adaptation in a dual sensor VVIR pacemaker
    • Van Krieken FM, Perrins JP, Sigmund M. Clinical results of automatic slope adaptation in a dual sensor VVIR pacemaker. PACE 1992; 15: 1815-1820.
    • (1992) PACE , vol.15 , pp. 1815-1820
    • Van Krieken, F.M.1    Perrins, J.P.2    Sigmund, M.3
  • 5
    • 10544248638 scopus 로고    scopus 로고
    • Automatic implant detection for initiating lead polarity programming and rate adaptive sensors: A multicenter study
    • Lau CP, Pietersen A, Ohm O, et al. Automatic implant detection for initiating lead polarity programming and rate adaptive sensors: A multicenter study (abstract). PACE 1996; 19:592.
    • (1996) PACE , vol.19 , pp. 592
    • Lau, C.P.1    Pietersen, A.2    Ohm, O.3
  • 6
    • 0028148531 scopus 로고
    • Quantitative comparison of rate response and oxygen uptake kinetics between different sensor modes in multisensor rate adaptive pacing
    • Leung SK, Lau CP, Wu CW, et al. Quantitative comparison of rate response and oxygen uptake kinetics between different sensor modes in multisensor rate adaptive pacing. PACE 1994; 17: 1920-1927.
    • (1994) PACE , vol.17 , pp. 1920-1927
    • Leung, S.K.1    Lau, C.P.2    Wu, C.W.3
  • 7
    • 0028721104 scopus 로고
    • Clinical usefulness of rate adaptive pacing systems: What should we assess?
    • Lau CP, Leung SK. Clinical usefulness of rate adaptive pacing systems: What should we assess? (editorial) PACE 1994; 17:2233-2235.
    • (1994) PACE , vol.17 , pp. 2233-2235
    • Lau, C.P.1    Leung, S.K.2
  • 8
    • 0024598481 scopus 로고
    • Comparison of exercise performance of six rate-adaptive right ventricular cardiac pacemakers
    • Lau CP, Butrous GS, Ward DE, et al. Comparison of exercise performance of six rate-adaptive right ventricular cardiac pacemakers. Am J Cardiol 1989; 63:833-838.
    • (1989) Am J Cardiol , vol.63 , pp. 833-838
    • Lau, C.P.1    Butrous, G.S.2    Ward, D.E.3
  • 9
    • 0023761126 scopus 로고
    • Comparative evaluation of chronotropic response of activity sensing and QT sensing rate responsive pacemakers to different activities
    • Mehta D, Lau CP, Ward DE, et al. Comparative evaluation of chronotropic response of activity sensing and QT sensing rate responsive pacemakers to different activities. PACE 1988; 11:1405-1414.
    • (1988) PACE , vol.11 , pp. 1405-1414
    • Mehta, D.1    Lau, C.P.2    Ward, D.E.3
  • 10
    • 0024332649 scopus 로고
    • Follow-up of an activity sensing, rate-modulated pacing device, including transtelephonic exercise assessment
    • Hayes DL, Christiansen JR, Vlietstra RE, et al. Follow-up of an activity sensing, rate-modulated pacing device, including transtelephonic exercise assessment. Mayo Clin Proc 1989; 64:503-508.
    • (1989) Mayo Clin Proc , vol.64 , pp. 503-508
    • Hayes, D.L.1    Christiansen, J.R.2    Vlietstra, R.E.3
  • 11
    • 10544225812 scopus 로고
    • Does the programmed lower rate affect the rate response in rate adaptive pacemakers?
    • Leung SK, Choi YC, Lau CP, et al. Does the programmed lower rate affect the rate response in rate adaptive pacemakers? PACE 1992; 15:579.
    • (1992) PACE , vol.15 , pp. 579
    • Leung, S.K.1    Choi, Y.C.2    Lau, C.P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.