메뉴 건너뛰기




Volumn 15, Issue 2, 2004, Pages 153-160

Prospective Randomized Study of Mode Switching in a Clinical Trial of Pacemaker Therapy for Sinus Node Dysfunction

Author keywords

Atrial fibrillation; Pacing; Sinus node dysfunction

Indexed keywords

AGED; ARTICLE; ARTIFICIAL HEART PACEMAKER; CARDIOVASCULAR SYSTEM; CLINICAL TRIAL; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; DEATH; DISEASE SEVERITY; FEMALE; FOLLOW UP; HEART ATRIUM FIBRILLATION; HEART FAILURE; HEART PACING; HOSPITALIZATION; HUMAN; MAJOR CLINICAL STUDY; MALE; PRIORITY JOURNAL; QUALITY OF LIFE; RANDOMIZED CONTROLLED TRIAL; SINGLE BLIND PROCEDURE; SINUS NODE DYSFUNCTION; STROKE; SYMPTOM; TREATMENT OUTCOME;

EID: 1542379955     PISSN: 10453873     EISSN: None     Source Type: Journal    
DOI: 10.1046/j.1540-8167.2004.03146.x     Document Type: Article
Times cited : (23)

References (57)
  • 4
    • 0035991554 scopus 로고    scopus 로고
    • Atrial fibrillation after DDDR pacemaker implantation
    • Gillis AM, Morck BA: Atrial fibrillation after DDDR pacemaker implantation. J Cardiovasc Electrophysiol 2002;13:542-547.
    • (2002) J Cardiovasc Electrophysiol , vol.13 , pp. 542-547
    • Gillis, A.M.1    Morck, B.A.2
  • 6
    • 0029079592 scopus 로고
    • Dual chamber pacing: How many patients remain in the DDD mode over the long term?
    • Ibrahim B, Sanderson JE, Wright B, Palmer R: Dual chamber pacing: How many patients remain in the DDD mode over the long term? Br Heart J 1995;74:76-79.
    • (1995) Br Heart J , vol.74 , pp. 76-79
    • Ibrahim, B.1    Sanderson, J.E.2    Wright, B.3    Palmer, R.4
  • 7
    • 0032911340 scopus 로고    scopus 로고
    • Survival of DDD pacing mode after atrioventricular junction ablation and pacing for refractory atrial fibrillation
    • Wood MA, Curtis AB, Takle-Newhouse TA, Ellenbogen KA: Survival of DDD pacing mode after atrioventricular junction ablation and pacing for refractory atrial fibrillation. Am Heart J 1999;137:682-685.
    • (1999) Am Heart J , vol.137 , pp. 682-685
    • Wood, M.A.1    Curtis, A.B.2    Takle-Newhouse, T.A.3    Ellenbogen, K.A.4
  • 8
    • 0029958133 scopus 로고    scopus 로고
    • Evaluation of a new pacing algorithm to prevent rapid tracking of atrial tachyarrhythmias
    • Kamalvand K, Kotsakis A, Tan K, Bucknall C, Sulke N: Evaluation of a new pacing algorithm to prevent rapid tracking of atrial tachyarrhythmias. Pacing Clin Electrophysiol 1996;19:1714-1718.
    • (1996) Pacing Clin Electrophysiol , vol.19 , pp. 1714-1718
    • Kamalvand, K.1    Kotsakis, A.2    Tan, K.3    Bucknall, C.4    Sulke, N.5
  • 10
    • 0031864021 scopus 로고    scopus 로고
    • Atrioventricular nodal ablation and implantation of mode switching dual chamber pacemakers: Effective treatment for drug refractory paroxysmal atrial fibrillation
    • Marshall HJ, Harris ZI, Griffith MK, Gammage MD: Atrioventricular nodal ablation and implantation of mode switching dual chamber pacemakers: Effective treatment for drug refractory paroxysmal atrial fibrillation. Heart 1998;79:543-547.
    • (1998) Heart , vol.79 , pp. 543-547
    • Marshall, H.J.1    Harris, Z.I.2    Griffith, M.K.3    Gammage, M.D.4
  • 12
    • 0030877125 scopus 로고    scopus 로고
    • Is mode switching beneficial? A randomized study in patients with paroxysmal atrial tachyarrhythmias
    • Kamalvand K, Tan K, Kotsakis A, Bucknall C, Sulke N: Is mode switching beneficial? A randomized study in patients with paroxysmal atrial tachyarrhythmias. J Am Coll Cardiol 1997;30:496-504.
    • (1997) J Am Coll Cardiol , vol.30 , pp. 496-504
    • Kamalvand, K.1    Tan, K.2    Kotsakis, A.3    Bucknall, C.4    Sulke, N.5
  • 13
    • 0030765111 scopus 로고    scopus 로고
    • Assessment of atrioventricular junction ablation and DDDR mode-switching pacemakers versus pharmacological treatment in patients with severely symptomatic paroxysmal atrial fibrillation: A randomized controlled study
    • Brignole M, Gainfranchi L, Menozzi C, Alboni P, Musso G, Bongiorni MG, Gasparini M, Raviele A, Lolli G, Paparella N, Acquarone S: Assessment of atrioventricular junction ablation and DDDR mode-switching pacemakers versus pharmacological treatment in patients with severely symptomatic paroxysmal atrial fibrillation: A randomized controlled study. Circulation 1997;96:2617-2624.
    • (1997) Circulation , vol.96 , pp. 2617-2624
    • Brignole, M.1    Gainfranchi, L.2    Menozzi, C.3    Alboni, P.4    Musso, G.5    Bongiorni, M.G.6    Gasparini, M.7    Raviele, A.8    Lolli, G.9    Paparella, N.10    Acquarone, S.11
  • 14
    • 0025308552 scopus 로고
    • Relation of prognosis in sick sinus syndrome to age, conduction defects and modes of permanent cardiac pacing
    • Santini M, Alexidou G, Ansalone G, Cacciatore G, Cini R, Turitto G: Relation of prognosis in sick sinus syndrome to age, conduction defects and modes of permanent cardiac pacing. Am J Cardiol 1990;65:729-735.
    • (1990) Am J Cardiol , vol.65 , pp. 729-735
    • Santini, M.1    Alexidou, G.2    Ansalone, G.3    Cacciatore, G.4    Cini, R.5    Turitto, G.6
  • 16
    • 1542266034 scopus 로고    scopus 로고
    • Emergence of atrial fibrillation as a new comorbidity in pacemaker patients: A natural history study
    • Abstract
    • Benditt DG, Mianulli M, Gorski J, Carr L, Neels K: Emergence of atrial fibrillation as a new comorbidity in pacemaker patients: A natural history study. (Abstract) Pacing Clin Electrophysiol 1999;22:902.
    • (1999) Pacing Clin Electrophysiol , vol.22 , pp. 902
    • Benditt, D.G.1    Mianulli, M.2    Gorski, J.3    Carr, L.4    Neels, K.5
  • 18
    • 0042354585 scopus 로고    scopus 로고
    • A randomized comparison of atrial and dual-chamber pacing in 177 consecutive patients with sick sinus syndrome: Echocardiographic and clinical outcome
    • Neilsen JC, Kristensen L, Andersen HR, Mortensen PT, Pedersen O, Pedersen AK: A randomized comparison of atrial and dual-chamber pacing in 177 consecutive patients with sick sinus syndrome: Echocardiographic and clinical outcome. J Am Coll Cardiol 2003;42:614-623.
    • (2003) J Am Coll Cardiol , vol.42 , pp. 614-623
    • Neilsen, J.C.1    Kristensen, L.2    Andersen, H.R.3    Mortensen, P.T.4    Pedersen, O.5    Pedersen, A.K.6
  • 19
    • 0038311033 scopus 로고    scopus 로고
    • Adverse effect of ventricular pacing on heart failure and atrial fibrillation among patients with normal baseline QRS duration in a clinical trial of pacemaker therapy for sinus node dysfunction
    • Sweeney MO, Hellkamp AS, Ellenbogen KA, Greenspon AJ, Freedman RA, Lee KL, Lamas GA: Adverse effect of ventricular pacing on heart failure and atrial fibrillation among patients with normal baseline QRS duration in a clinical trial of pacemaker therapy for sinus node dysfunction. Circulation 2003;23:2932-2937.
    • (2003) Circulation , vol.23 , pp. 2932-2937
    • Sweeney, M.O.1    Hellkamp, A.S.2    Ellenbogen, K.A.3    Greenspon, A.J.4    Freedman, R.A.5    Lee, K.L.6    Lamas, G.A.7
  • 20
    • 0002288018 scopus 로고    scopus 로고
    • Basic physiology of cardiac pacing and pacemaker syndrome
    • Ellenbogen KA, Wilkoff BL, eds: Philadelphia: WB Saunders
    • Janosik DL, Ellenbogen KA: Basic physiology of cardiac pacing and pacemaker syndrome. In Ellenbogen KA, Wilkoff BL, eds: Clinical Cardiac Pacing and Defibrillation. Second Edition. Philadelphia: WB Saunders, 2000:333-352.
    • (2000) Clinical Cardiac Pacing and Defibrillation. Second Edition , pp. 333-352
    • Janosik, D.L.1    Ellenbogen, K.A.2
  • 22
    • 0028114538 scopus 로고
    • Initial experience with a new algorithm for automatic mode switching from DDDR to DDIR mode
    • Ovsyshcher IE, Katz A, Bondy C: Initial experience with a new algorithm for automatic mode switching from DDDR to DDIR mode. Pacing Clin Electrophysiol 1994;17:1908-1912.
    • (1994) Pacing Clin Electrophysiol , vol.17 , pp. 1908-1912
    • Ovsyshcher, I.E.1    Katz, A.2    Bondy, C.3
  • 23
  • 24
    • 0033927352 scopus 로고    scopus 로고
    • High rate atrial tachyarrhythmia detections in implantable pulse generators: Low incidence of false positive detections
    • Fitts SM, Hill MRS, Mehra R, Gillis AM, for the PA3 Clinical Trial Investigators: High rate atrial tachyarrhythmia detections in implantable pulse generators: Low incidence of false positive detections. Pacing Clin Electrophysiol 2000;23:1080-1086.
    • (2000) Pacing Clin Electrophysiol , vol.23 , pp. 1080-1086
    • Fitts, S.M.1    Hill, M.R.S.2    Mehra, R.3    Gillis, A.M.4
  • 28
    • 0029776399 scopus 로고    scopus 로고
    • Effect of radiofrequency catheter ablation on health-related quality of life and activities of daily living in patients with recurrent arrhythmias
    • Bubien R, Knotts-Dolson S, Plumb VJ, Kay GN: Effect of radiofrequency catheter ablation on health-related quality of life and activities of daily living in patients with recurrent arrhythmias. Circulation 1996;94:1585-1591.
    • (1996) Circulation , vol.94 , pp. 1585-1591
    • Bubien, R.1    Knotts-Dolson, S.2    Plumb, V.J.3    Kay, G.N.4
  • 29
    • 0026713822 scopus 로고
    • Quality-of-life in patients treated with atrioventricular synchronous pacing compared to rate modulated ventricularpacing: A long-term, double-blind, crossover study
    • Linde-Edelstam C, NordlanderR, Unden A-L, Orth-Gomer K, Ryden L: Quality-of-life in patients treated with atrioventricular synchronous pacing compared to rate modulated ventricularpacing: A long-term, double-blind, crossover study. Pacing Clin Electrophysiol 1992;15:1467-1476.
    • (1992) Pacing Clin Electrophysiol , vol.15 , pp. 1467-1476
    • Linde-Edelstam, C.1    Nordlander, R.2    Unden, A.-L.3    Orth-Gomer, K.4    Ryden, L.5
  • 30
    • 0033616919 scopus 로고    scopus 로고
    • Prospective study of ablation and pacing versus medical therapy for paroxysmal atrial fibrillation. Effects of pacing mode and mode-switch algorithms
    • Marshall HJ, Harris ZI, Griffith MJ, Holder RL, Gammage MD: Prospective study of ablation and pacing versus medical therapy for paroxysmal atrial fibrillation. Effects of pacing mode and mode-switch algorithms. Circulation 1999;99:1587-1592.
    • (1999) Circulation , vol.99 , pp. 1587-1592
    • Marshall, H.J.1    Harris, Z.I.2    Griffith, M.J.3    Holder, R.L.4    Gammage, M.D.5
  • 31
    • 0035106283 scopus 로고    scopus 로고
    • Acute and long-term effects of atrioventricular junction ablation and VVIR pacemaker in symptomatic patients with chronic lone atrial fibrillation and normal ventricular response
    • Ueng KC, Tsai TP, Tsai CF, Wu DJ, Lin CS, Lee SH, Chen SA: Acute and long-term effects of atrioventricular junction ablation and VVIR pacemaker in symptomatic patients with chronic lone atrial fibrillation and normal ventricular response. J Cardiovasc Electrophysiol 2001;12:303-309.
    • (2001) J Cardiovasc Electrophysiol , vol.12 , pp. 303-309
    • Ueng, K.C.1    Tsai, T.P.2    Tsai, C.F.3    Wu, D.J.4    Lin, C.S.5    Lee, S.H.6    Chen, S.A.7
  • 33
    • 0019786466 scopus 로고
    • Comparative reproducibility and validity systems for assessing cardiovascular function class: Advantages of a new specific activity scale
    • Goldman L, Hashimoto B, Cook EF, Loscalzo A: Comparative reproducibility and validity systems for assessing cardiovascular function class: Advantages of a new specific activity scale. Circulation 1981;64:1227-1234.
    • (1981) Circulation , vol.64 , pp. 1227-1234
    • Goldman, L.1    Hashimoto, B.2    Cook, E.F.3    Loscalzo, A.4
  • 34
    • 0026877917 scopus 로고
    • The MOS 36-item short-form health status survey (SF-36): Conceptual framework and item selection
    • Ware JE, Sherbourne CD: The MOS 36-item short-form health status survey (SF-36): conceptual framework and item selection. Med Care 1992;30:473-483.
    • (1992) Med Care , vol.30 , pp. 473-483
    • Ware, J.E.1    Sherbourne, C.D.2
  • 36
    • 0000336139 scopus 로고
    • Regression models and life-tables
    • Cox DR: Regression models and life-tables. J R Stat Soc B 1972;34:187-220.
    • (1972) J R Stat Soc B , vol.34 , pp. 187-220
    • Cox, D.R.1
  • 38
    • 0020622279 scopus 로고
    • Influence of atrial systole on the Frank-Starling relations and the end-diastolic pressure-diameter relation of the left ventricle
    • Linderer T, Chatterjee K, Parmley WW, Sievers RE, Glantz SA, Tyberg JV: Influence of atrial systole on the Frank-Starling relations and the end-diastolic pressure-diameter relation of the left ventricle. Circulation 1983;67:1045-1053.
    • (1983) Circulation , vol.67 , pp. 1045-1053
    • Linderer, T.1    Chatterjee, K.2    Parmley, W.W.3    Sievers, R.E.4    Glantz, S.A.5    Tyberg, J.V.6
  • 39
    • 0014376252 scopus 로고
    • Alterations in cardiac function immediately following electrical cardioversion of atrial fibrillation to normal sinus rhythm
    • Shapiro W, Klein G: Alterations in cardiac function immediately following electrical cardioversion of atrial fibrillation to normal sinus rhythm. Circulation 1968;38:1074-1084.
    • (1968) Circulation , vol.38 , pp. 1074-1084
    • Shapiro, W.1    Klein, G.2
  • 40
    • 0018579508 scopus 로고
    • Hemodynamics and echocardiograms before and after cardioversion of atrial fibrillation to normal sinus rhythm
    • Orlando JR, Van Herick R, Aronow WAS, Olson HG: Hemodynamics and echocardiograms before and after cardioversion of atrial fibrillation to normal sinus rhythm. Chest 1979;76:521-526.
    • (1979) Chest , vol.76 , pp. 521-526
    • Orlando, J.R.1    Van Herick, R.2    Aronow, W.A.S.3    Olson, H.G.4
  • 42
    • 0030777184 scopus 로고    scopus 로고
    • Hemodynamic effects of an irregular sequence of ventricular cycle length during atrial fibrillation
    • Clark DM, Plumb VJ, Epstein AE, Kay GN: Hemodynamic effects of an irregular sequence of ventricular cycle length during atrial fibrillation. J Am Coll Cardiol 1997;30:1039-1045.
    • (1997) J Am Coll Cardiol , vol.30 , pp. 1039-1045
    • Clark, D.M.1    Plumb, V.J.2    Epstein, A.E.3    Kay, G.N.4
  • 43
    • 0030021807 scopus 로고    scopus 로고
    • Comparison of bipolar atrial electrogram amplitude in sinusrhythm, atrial fibrillation, and atrial flutter
    • Wood MA, Moskovljevic P, Stambler BS, Ellenbogen KA: Comparison of bipolar atrial electrogram amplitude in sinusrhythm, atrial fibrillation, and atrial flutter. Pacing Clin Electrophysiol 1996;19:150-156.
    • (1996) Pacing Clin Electrophysiol , vol.19 , pp. 150-156
    • Wood, M.A.1    Moskovljevic, P.2    Stambler, B.S.3    Ellenbogen, K.A.4
  • 45
    • 0036316527 scopus 로고    scopus 로고
    • Automatic mode switching of implantable pacemakers: II. Clinical performance of current algorithms and their programming
    • Lau CP, Leung SK, Tse HF, Barold SS: Automatic mode switching of implantable pacemakers: II. Clinical performance of current algorithms and their programming. Pacing Clin Electrophysiol 2002;25:1094-1113.
    • (2002) Pacing Clin Electrophysiol , vol.25 , pp. 1094-1113
    • Lau, C.P.1    Leung, S.K.2    Tse, H.F.3    Barold, S.S.4
  • 46
    • 0031724365 scopus 로고    scopus 로고
    • Programmed atrial sensitivity: A critical determinant in atrial fibrillation detection and optimal automatic mode switching
    • Leung SK, Lau CP, Lam CT, Tse HF, Tang MO, Chung F, Ayers G: Programmed atrial sensitivity: A critical determinant in atrial fibrillation detection and optimal automatic mode switching. Pacing Clin Electrophysiol 1998;21:2214-2219.
    • (1998) Pacing Clin Electrophysiol , vol.21 , pp. 2214-2219
    • Leung, S.K.1    Lau, C.P.2    Lam, C.T.3    Tse, H.F.4    Tang, M.O.5    Chung, F.6    Ayers, G.7
  • 47
    • 0034494854 scopus 로고    scopus 로고
    • A comparative study on the behavior of three difference automatic mode switching dual chamber pacemakers to intracardiac recordings of clinical atrial fibrillation
    • Leung SK, Lau CP, Lam CT, Tse HF, Tang MO, Chung F, Ayers G: A comparative study on the behavior of three difference automatic mode switching dual chamber pacemakers to intracardiac recordings of clinical atrial fibrillation. Pacing Clin Electrophysiol 2000;23:2086-2096.
    • (2000) Pacing Clin Electrophysiol , vol.23 , pp. 2086-2096
    • Leung, S.K.1    Lau, C.P.2    Lam, C.T.3    Tse, H.F.4    Tang, M.O.5    Chung, F.6    Ayers, G.7
  • 50
    • 0037176263 scopus 로고    scopus 로고
    • Dual-chamber pacing or ventricular backup pacing in patients with an implantable defibrillator: The Dual Chamber and VVI Implantable Defibrillator (DAVID) Trial
    • The DAVID Trial Investigators: Dual-chamber pacing or ventricular backup pacing in patients with an implantable defibrillator: The Dual Chamber and VVI Implantable Defibrillator (DAVID) Trial. JAMA 2002;288:3115-3123.
    • (2002) JAMA , vol.288 , pp. 3115-3123
  • 52
    • 1542355939 scopus 로고    scopus 로고
    • Long AV intervals permit reduction of ventricular pacing in a randomized trial of a new minimal ventricular pacing mode (MVP) in patients with dual chamber ICDs
    • Abstract
    • Sweeney MO, Shea JB, Fox V, Adler S, Nelson L, Sheldon T, Mullen T, Belk P, Casavant D: Long AV intervals permit reduction of ventricular pacing in a randomized trial of a new minimal ventricular pacing mode (MVP) in patients with dual chamber ICDs. (Abstract) Pacing Clin Electrophysiol 2003;26:1058.
    • (2003) Pacing Clin Electrophysiol , vol.26 , pp. 1058
    • Sweeney, M.O.1    Shea, J.B.2    Fox, V.3    Adler, S.4    Nelson, L.5    Sheldon, T.6    Mullen, T.7    Belk, P.8    Casavant, D.9
  • 53
    • 0023002153 scopus 로고
    • Rate stabilization by right ventricular pacing in patients with atrial fibrillation
    • Wittkampf FHM, De Jongste MJL: Rate stabilization by right ventricular pacing in patients with atrial fibrillation. Pacing Clin Electrophysiol 1986;9:1147-1153.
    • (1986) Pacing Clin Electrophysiol , vol.9 , pp. 1147-1153
    • Wittkampf, F.H.M.1    De Jongste, M.J.L.2
  • 55
    • 0029907772 scopus 로고    scopus 로고
    • Optimized standby rate reduces the ventricular rate variability in pacemaker patients with atrial fibrillation
    • Greenhut SA, Fraser J, Steinhaus D, Feld G, Hughes W: Optimized standby rate reduces the ventricular rate variability in pacemaker patients with atrial fibrillation. Pacing Clin Electrophysiol 1996;19:1780-1785.
    • (1996) Pacing Clin Electrophysiol , vol.19 , pp. 1780-1785
    • Greenhut, S.A.1    Fraser, J.2    Steinhaus, D.3    Feld, G.4    Hughes, W.5
  • 56
    • 0034906797 scopus 로고    scopus 로고
    • Safety and feasibility of a novel rate-smoothed ventricular pacing algorithm for atrial fibrillation
    • Simpson CS, Yee R, Lee JK, Braney M, Klein GJ, Krahn AD, Skanes AC: Safety and feasibility of a novel rate-smoothed ventricular pacing algorithm for atrial fibrillation. Am Heart J 2001;142:294-300.
    • (2001) Am Heart J , vol.142 , pp. 294-300
    • Simpson, C.S.1    Yee, R.2    Lee, J.K.3    Braney, M.4    Klein, G.J.5    Krahn, A.D.6    Skanes, A.C.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.