-
1
-
-
0023690491
-
Long-term pacing in sinus node dysfunction: Effect of stimulation mode on cardiovascular morbidity and mortality
-
Rosenquist M, Brandt J, Schuller H. Long-term pacing in sinus node dysfunction: Effect of stimulation mode on cardiovascular morbidity and mortality. Am Heart J 1988; 116:16.
-
(1988)
Am Heart J
, vol.116
, pp. 16
-
-
Rosenquist, M.1
Brandt, J.2
Schuller, H.3
-
2
-
-
0025667758
-
Clinical predictors and natural history of atrial fibrillation in patients with DDD pacemakers
-
Gross J, Moser S, Benedek M, et al. Clinical predictors and natural history of atrial fibrillation in patients with DDD pacemakers. PACE 1990; 13: 1828-1831.
-
(1990)
PACE
, vol.13
, pp. 1828-1831
-
-
Gross, J.1
Moser, S.2
Benedek, M.3
-
3
-
-
0028104147
-
The automatic mode switching function in successive generations of minute ventilation sensing dual chamber rate responsive pacemakers
-
Provenier F, Jordaens L, Verstraeten T, et al. The automatic mode switching function in successive generations of minute ventilation sensing dual chamber rate responsive pacemakers. PACE 1994; 17(2) : 1913-1919.
-
(1994)
PACE
, vol.17
, Issue.2
, pp. 1913-1919
-
-
Provenier, F.1
Jordaens, L.2
Verstraeten, T.3
-
4
-
-
0028114538
-
Initial experience with a new algorithm for automatic mode switching from DDDR to DDIR mode
-
Ovsyshcher I, Katz A, Bondy C. Initial experience with a new algorithm for automatic mode switching from DDDR to DDIR mode. PACE 1994; 17(2): 1908-19 12.
-
(1994)
PACE
, vol.17
, Issue.2
, pp. 1908-1912
-
-
Ovsyshcher, I.1
Katz, A.2
Bondy, C.3
-
5
-
-
0028019301
-
Initial experience with mode switching in a dual sensor, dual chamber pacemaker in patients with paroxysmal atrial tacliyarrhythmias
-
Dulk K, Dijkman B, Pieterse M, et al. Initial experience with mode switching in a dual sensor, dual chamber pacemaker in patients with paroxysmal atrial tacliyarrhythmias. PACE 1994; 17(2): 1900-1907.
-
(1994)
PACE
, vol.17
, Issue.2
, pp. 1900-1907
-
-
Dulk, K.1
Dijkman, B.2
Pieterse, M.3
-
6
-
-
0025601727
-
A new feature for control of inappropriate high rate tracking in DDDR pacemakers
-
Lee MT, Adkins A, Woodson D, et al. A new feature for control of inappropriate high rate tracking in DDDR pacemakers. PACE 1990; 13(2): 1852-1855.
-
(1990)
PACE
, vol.13
, Issue.2
, pp. 1852-1855
-
-
Lee, M.T.1
Adkins, A.2
Woodson, D.3
-
7
-
-
0008774708
-
Initial experience with a new sensor driven algorithm limiting ventricular pacing rate during supraventricular tachycardia
-
Mahaux V, Verboven Y, Waleffe A, et al. Initial experience with a new sensor driven algorithm limiting ventricular pacing rate during supraventricular tachycardia. PACE 1992; 15:577.
-
(1992)
PACE
, vol.15
, pp. 577
-
-
Mahaux, V.1
Verboven, Y.2
Waleffe, A.3
-
8
-
-
0026574537
-
Clinical experience with an activity sensing DDDR pacemaker using an accelerometer sensor
-
Lau CP, Tai YT, Fong PC, et al. Clinical experience with an activity sensing DDDR pacemaker using an accelerometer sensor. PACE 1992; 15:334.
-
(1992)
PACE
, vol.15
, pp. 334
-
-
Lau, C.P.1
Tai, Y.T.2
Fong, P.C.3
-
9
-
-
0002889603
-
Optimal antibradycardia pacing in patients with paroxysmal supraventricular tachyarrhythmias: Role of fallback and automatic mode switching mechanisms
-
Mount Kisco, NY, Futura Publishing Co., Inc.
-
Barold SS, Mond HG. Optimal antibradycardia pacing in patients with paroxysmal supraventricular tachyarrhythmias: Role of fallback and automatic mode switching mechanisms. In: New Perspectives in Cardiac Pacing. Vol. 3. Mount Kisco, NY, Futura Publishing Co., Inc., 1993, pp. 483-518.
-
(1993)
New Perspectives in Cardiac Pacing
, vol.3
, pp. 483-518
-
-
Barold, S.S.1
Mond, H.G.2
-
10
-
-
0037702422
-
Effect of a regular and irregular cardiac rhythm on cardiac output
-
4
-
Daoud E, Weiss I, Bahu M, et al. Effect of a regular and irregular cardiac rhythm on cardiac output. PACE 1996; 19:4(2): 691A.
-
(1996)
PACE
, vol.19
, Issue.2
-
-
Daoud, E.1
Weiss, I.2
Bahu, M.3
-
11
-
-
0344073507
-
Acute and medium-term results of atrioventricular mode modification in patients with atrial fibrillation or flutter
-
Bella PD, Toudo C, Riva S, et al. Acute and medium-term results of atrioventricular mode modification in patients with atrial fibrillation or flutter. PACE 1995; 18(2): 859A.
-
(1995)
PACE
, vol.18
, Issue.2
-
-
Bella, P.D.1
Toudo, C.2
Riva, S.3
|