메뉴 건너뛰기




Volumn 16, Issue 3, 2005, Pages 307-311

Trap for MAbs: Characterization of intact monoclonal antibodies using reversed-phase HPLC on-line with ion-trap mass spectrometry

Author keywords

[No Author keywords available]

Indexed keywords

ACETONITRILE; CARBOXYLIC ACIDS; CHARACTERIZATION; ELECTRIC POTENTIAL; ETHANOL; HIGH PERFORMANCE LIQUID CHROMATOGRAPHY; MACROMOLECULES; MASS SPECTROMETERS; ONLINE SYSTEMS; OPTIMIZATION; WATER;

EID: 14744293331     PISSN: 10440305     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jasms.2004.11.004     Document Type: Article
Times cited : (16)

References (32)
  • 1
    • 0033866627 scopus 로고    scopus 로고
    • Antibody Humanization: A Case of the "emperor's new clothes"
    • M.R. Clark Antibody Humanization A Case of the "Emperor's new clothes" Immunol. Today 21 8 2000 397 420
    • (2000) Immunol. Today , vol.21 , Issue.8 , pp. 397-420
    • Clark, M.R.1
  • 2
    • 0028258349 scopus 로고
    • Characterization of Humanized Anti-Tac, an Antibody Directed Against the Interleukin 2 Receptor, Using Electrospray Ionization Mass Spectrometry by Direct Infusion LC/MS and MS/MS
    • D.A. Lewis, A.W. Guzzetta, W.S. Handcock Characterization of Humanized Anti-Tac, an Antibody Directed Against the Interleukin 2 Receptor, Using Electrospray Ionization Mass Spectrometry by Direct Infusion LC/MS and MS/MS Anal. Chem 66 1994 585 595
    • (1994) Anal. Chem , vol.66 , pp. 585-595
    • Lewis, D.A.1    Guzzetta, A.W.2    Handcock, W.S.3
  • 3
    • 0024438708 scopus 로고
    • Electrospray Ionization for Mass-Spectrometry of Large Biomolecules
    • J.B. Fenn, M. Mann, C.K. Wang, S.F. Wong, C.M. Whitehouse Electrospray Ionization for Mass-Spectrometry of Large Biomolecules Science 246 1989 64 71
    • (1989) Science , vol.246 , pp. 64-71
    • Fenn, J.B.1    Mann, M.2    Wang, C.K.3    Wong, S.F.4    Whitehouse, C.M.5
  • 4
    • 0029685702 scopus 로고    scopus 로고
    • Analytical Properties of the Nanoelectrospray Ion Source
    • M.S. Wilm, M. Mann Analytical Properties of the Nanoelectrospray Ion Source Anal. Chem 68 1996 1 8
    • (1996) Anal. Chem , vol.68 , pp. 1-8
    • Wilm, M.S.1    Mann, M.2
  • 5
    • 0031195015 scopus 로고    scopus 로고
    • Development and Evaluation of On-Line Nanoliter Flow Analysis of Proteins Digests by Pneumatic-Splitter Electrospray Liquid Chromatography Mass Spectrometry
    • J.C. Le, J. Hui, M. Haniu, V. Katta, M.F.J. Rhode Development and Evaluation of On-Line Nanoliter Flow Analysis of Proteins Digests by Pneumatic-Splitter Electrospray Liquid Chromatography Mass Spectrometry J. Am. Soc. Mass Spectrom 8 1997 703 712
    • (1997) J. Am. Soc. Mass Spectrom , vol.8 , pp. 703-712
    • Le J., C.1    Hui, J.2    Haniu, M.3    Katta, V.4    Rhode, M.F.J.5
  • 7
    • 0028787777 scopus 로고
    • Monitoring of IgG Antibody Thermal Stability by Micellar Electrokinetic Capillary Chromatography and Matrix-Assisted Laser Desorption/Ionnization Mass Spectrometry
    • J.A. Alexander, E.D. Hughes Monitoring of IgG Antibody Thermal Stability by Micellar Electrokinetic Capillary Chromatography and Matrix-Assisted Laser Desorption/Ionnization Mass Spectrometry Anal. Chem 67 1995 3626 3632
    • (1995) Anal. Chem , vol.67 , pp. 3626-3632
    • Alexander, J.A.1    Hughes, E.D.2
  • 8
    • 0034100284 scopus 로고    scopus 로고
    • Contributions of Mass Spectrometry to Structural Immunology
    • K.M. Downard Contributions of Mass Spectrometry to Structural Immunology J. Mass Spectrom 35 2000 493 503
    • (2000) J. Mass Spectrom , vol.35 , pp. 493-503
    • Downard, K.M.1
  • 9
    • 0028064214 scopus 로고
    • Reflecting Time-of-Flight Mass Spectrometer with an Electrospray Ion Source and Orthogonal Extraction
    • A.N. Verentchikov, W. Ens, K.G. Standing Reflecting Time-of-Flight Mass Spectrometer with an Electrospray Ion Source and Orthogonal Extraction Anal. Chem 66 1995 126 133
    • (1995) Anal. Chem , vol.66 , pp. 126-133
    • Verentchikov, A.N.1    Ens, W.2    Standing, K.G.3
  • 10
    • 0035193327 scopus 로고    scopus 로고
    • Probing Molecular Interaction in Intact Antibody: Antigen Complexes, an Electrospray Time-of Flight Mass Spectrometry Approach
    • M.A. Tito, K. Tars, K. Valegard, J. Hajdu, C.V. Robinson Probing Molecular Interaction in Intact Antibody Antigen Complexes, an Electrospray Time-of Flight Mass Spectrometry Approach Biophys. J 81 2001 3503 3509
    • (2001) Biophys. J , vol.81 , pp. 3503-3509
    • Tito, M.A.1    Tars, K.2    Valegard, K.3    Hajdu, J.4    Robinson, C.V.5
  • 11
    • 0028787776 scopus 로고
    • An integrated Strategy for Structure Characterization of the Protein and Carbohydrate Components of Monoclonal Antibodies: Application to Anti-Respiratory Syncytial Virus MAB
    • G.D. Robert, W.P. Johnson, S. Burman, K.R. Anumula, S.A. Carr An integrated Strategy for Structure Characterization of the Protein and Carbohydrate Components of Monoclonal Antibodies Application to Anti-Respiratory Syncytial Virus MAB Anal. Chem 67 1995 3613 3625
    • (1995) Anal. Chem , vol.67 , pp. 3613-3625
    • Robert, G.D.1    Johnson, W.P.2    Burman, S.3    Anumula, K.R.4    Carr, S.A.5
  • 12
    • 0030043319 scopus 로고    scopus 로고
    • Rapid Characterization of Chemically-Modified Proteins by Electrospray Mass Spectrometry
    • K.L. Bennett, S.V. Smith, R.M. Lambrecht, R.J.W. Truscott, M.M. Sheil Rapid Characterization of Chemically-Modified Proteins by Electrospray Mass Spectrometry Bioconj. Chem 7 1996 16 22
    • (1996) Bioconj. Chem , vol.7 , pp. 16-22
    • Bennett, K.L.1    Smith, S.V.2    Lambrecht, R.M.3    Truscott, R.J.W.4    Sheil, M.M.5
  • 14
    • 14744292238 scopus 로고    scopus 로고
    • Trap for MAbs: Novel Approach to Characterize Intact Antibodies and Degradation Products Using RP-HPLC and Ion-Trap Mass Spectrometry
    • J.C. Le, P. Bondarenko Trap for MAbs Novel Approach to Characterize Intact Antibodies and Degradation Products Using RP-HPLC and Ion-Trap Mass Spectrometry Proceedings of the 52nd ASMS Conference 2004 Nashville, TN, May
    • (2004) Proceedings of the 52nd ASMS Conference
    • Le J., C.1    Bondarenko, P.2
  • 16
    • 5644302352 scopus 로고    scopus 로고
    • Development of an Analytical Reversed-Phase High-Performance Liquid Chromatography-Electrospray Ionization Mass Spectrometry Method for Characterization of Recombinant Antibodies
    • T.M. Dillon, P.V. Bondarenko, M. Speed Ricci Development of an Analytical Reversed-Phase High-Performance Liquid Chromatography-Electrospray Ionization Mass Spectrometry Method for Characterization of Recombinant Antibodies J. Chromatogr. A 1053 2004 299 305
    • (2004) J. Chromatogr. a , vol.1053 , pp. 299-305
    • Dillon, T.M.1    Bondarenko, P.V.2    Speed Ricci, M.3
  • 17
    • 2442676973 scopus 로고    scopus 로고
    • Reversed Phase HPLC/MS Method for Analysis of Post-Translational Modification of Monoclonal Antibody in Cell Culture Media
    • T. Eris, J. Liu Reversed Phase HPLC/MS Method for Analysis of Post-Translational Modification of Monoclonal Antibody in Cell Culture Media Proceedings of the 50th ASMS Conference 2002 Orlando, FL, June
    • (2002) Proceedings of the 50th ASMS Conference
    • Eris, T.1    Liu, J.2
  • 18
    • 0035943486 scopus 로고    scopus 로고
    • Affinity Reversed Phase Liquid Chromatography Assay to Quantitate Recombinant Antibodies and Antibody Fragments in Fermentation Broth
    • J.E. Battersby, B. Snedecor, C. Chen, K.M. Champion, L. Riddle, M. Vanderlaan Affinity Reversed Phase Liquid Chromatography Assay to Quantitate Recombinant Antibodies and Antibody Fragments in Fermentation Broth J. Chromatogr. A 972 2000 61 76
    • (2000) J. Chromatogr. a , vol.972 , pp. 61-76
    • Battersby, J.E.1    Snedecor, B.2    Chen, C.3    Champion, K.M.4    Riddle, L.5    Vanderlaan, M.6
  • 19
    • 0028883956 scopus 로고
    • Enhanced Sensitivity for Peptide Mapping with Electrospray Liquid Chromatography-Mass Spectrometry in the Presence of Signal Suppression Due to Trifluoroacetic Acid-Containing Mobile Phases
    • A. Apffel, S. Fischer, G. Goldberg, P.C. Goodley, F.E. Kuhlmann Enhanced Sensitivity for Peptide Mapping with Electrospray Liquid Chromatography-Mass Spectrometry in the Presence of Signal Suppression Due to Trifluoroacetic Acid-Containing Mobile Phases J. Chromatogr. A 712 1995 177 190
    • (1995) J. Chromatogr. a , vol.712 , pp. 177-190
    • Apffel, A.1    Fischer, S.2    Goldberg, G.3    Goodley, P.C.4    Kuhlmann, F.E.5
  • 20
    • 0000474331 scopus 로고
    • Characterization of Protein O-Glycosylation by Reversed-Phase Microbore Liquid Chromatography/Electrospray Mass Spectrometry, Complementary Mobile Phases, and Sequential Exoglycosidase Digestion
    • K.F. Medzihradszky, D.A. Maltby, S.C. Hall, C.A. Settineri, A.L. Burlingame Characterization of Protein O-Glycosylation by Reversed-Phase Microbore Liquid Chromatography/Electrospray Mass Spectrometry, Complementary Mobile Phases, and Sequential Exoglycosidase Digestion J. Am. Soc. Mass Spectrom 5 1994 350 358
    • (1994) J. Am. Soc. Mass Spectrom , vol.5 , pp. 350-358
    • Medzihradszky, K.F.1    Maltby, D.A.2    Hall, S.C.3    Settineri, C.A.4    Burlingame, A.L.5
  • 21
    • 14744299361 scopus 로고    scopus 로고
    • German Pattent 944900; 1956. U.S. Patent 2939 952; 1960.
    • Paul, W.; Steinwedel, H. German Pattent 944900; 1956. U.S. Patent 2939 952; 1960.
    • Paul, W.1    Steinwedel, H.2
  • 22
    • 33748216155 scopus 로고
    • Electromagnetic Traps for Charged and Neutral Particles (Nobel lecture)
    • W. Paul Electromagnetic Traps for Charged and Neutral Particles (Nobel lecture) Angew. Chem 29 1990 739 748
    • (1990) Angew. Chem , vol.29 , pp. 739-748
    • Paul, W.1
  • 23
    • 0030999705 scopus 로고    scopus 로고
    • An Introduction to Quadrupole Ion Trap Mass Spectrometry
    • R.E. March An Introduction to Quadrupole Ion Trap Mass Spectrometry J. Mass Spectrom 32 1997 351 369
    • (1997) J. Mass Spectrom , vol.32 , pp. 351-369
    • March, R.E.1
  • 27
    • 0037446706 scopus 로고    scopus 로고
    • Ion Trap Mass Spectrometry of Fluorescently Labeled Nanoparticles
    • Y. Cai, W.P. Peng, H.C. Chang Ion Trap Mass Spectrometry of Fluorescently Labeled Nanoparticles Anal. Chem 75 2003 1805 1811
    • (2003) Anal. Chem , vol.75 , pp. 1805-1811
    • Cai, Y.1    Peng, W.P.2    Chang, H.C.3
  • 28
    • 0002586885 scopus 로고
    • Equilibrium Space Charge Distribution in a Quadrupole Ion Trap
    • S. Guan, A.G. Marshall Equilibrium Space Charge Distribution in a Quadrupole Ion Trap J. Am. Soc. Mass Spectrom 5 1994 64 71
    • (1994) J. Am. Soc. Mass Spectrom , vol.5 , pp. 64-71
    • Guan, S.1    Marshall, A.G.2
  • 30
    • 0030809823 scopus 로고    scopus 로고
    • Determination of Tumor Necrosis Factor Binding Protein Disulfide Structure: Deviation of the Fourth Domain Structure from the TNFR/NGFR Family Cysteine-Rich Region Signature
    • M.D. Jones, J. Hunt, J.L. Liu, S.D. Patterson, T. Kohno, H.S. Lu Determination of Tumor Necrosis Factor Binding Protein Disulfide Structure Deviation of the Fourth Domain Structure from the TNFR/NGFR Family Cysteine-Rich Region Signature Biochemistry 36 1997 14914 14923
    • (1997) Biochemistry , vol.36 , pp. 14914-14923
    • Jones, M.D.1    Hunt, J.2    Liu, J.L.3    Patterson, S.D.4    Kohno, T.5    Lu, H.S.6
  • 31
    • 14744295962 scopus 로고
    • Method and Apparatus for Focusing Ions in Viscous Flow Jet Expansion Region of an Electrospray Apparatus
    • I.C. Mylchreest, M.E. Hail, J.R. Herron Method and Apparatus for Focusing Ions in Viscous Flow Jet Expansion Region of an Electrospray Apparatus Thermo Finnigan U.S. Patent 5157260 1992
    • (1992) Thermo Finnigan U.S. Patent 5157260
    • Mylchreest, I.C.1    Hail, M.E.2    Herron, J.R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.