Volumn 28, Issue 5, 2005, Pages 713-725
|
Development and validation of a sensitive and robust wipe-test method for the detection and quantification of the antibiotic ertapenem and its primary degradates in a pharmaceutical manufacturing environment
|
Author keywords
Antibiotics; Cleaning validation; Ertapenem; HPLC; Manufacturing; Pharmaceuticals; Swab analysis
|
Indexed keywords
ACETONITRILE;
ANTIBIOTICS;
PH EFFECTS;
SOLUTIONS;
ULTRAVIOLET DETECTORS;
ACID BUFFERS;
LIMIT OF DETECTION (LOD);
LIMIT OF QUANTITATION (LOQ);
SOLUTION STABILITY;
HIGH PERFORMANCE LIQUID CHROMATOGRAPHY;
ACETONITRILE;
ERTAPENEM;
PHOSPHORIC ACID;
AQUEOUS SOLUTION;
ARTICLE;
DRUG DEGRADATION;
DRUG DETERMINATION;
DRUG MANUFACTURE;
ELUTION;
ENVIRONMENTAL TEMPERATURE;
HIGH PERFORMANCE LIQUID CHROMATOGRAPHY;
HYDROLYSIS;
METHODOLOGY;
QUANTITATIVE ANALYSIS;
RESIDUE ANALYSIS;
ULTRAVIOLET RADIATION;
VALIDATION PROCESS;
WIPE TEST;
|