메뉴 건너뛰기




Volumn 26, Issue 1, 2005, Pages

Performance characteristics of gas analysis systems: What we know and what we need to know

Author keywords

Calibration; Error sources; Precision of estimate; Systematic and random errors; Uniform and proportional errors

Indexed keywords

ACCURACY; ANALYTICAL ERROR; DECISION MAKING; EXAMINATION; FEMALE; GAS ANALYSIS; GAS EXCHANGE; HUMAN; MALE; MEASUREMENT; OUTCOMES RESEARCH; PRACTICE GUIDELINE; REVIEW; TECHNIQUE;

EID: 14244255276     PISSN: 0943917X     EISSN: None     Source Type: Journal    
DOI: 10.1055/s-2004-830505     Document Type: Review
Times cited : (63)

References (42)
  • 2
    • 0031790628 scopus 로고    scopus 로고
    • Statistical methods in assessing measurement error (reliability) in variables relevant to sports medicine
    • Atkinson G, Nevill AM. Statistical methods in assessing measurement error (reliability) in variables relevant to sports medicine. Sports Med 1998; 26: 217-238
    • (1998) Sports Med , vol.26 , pp. 217-238
    • Atkinson, G.1    Nevill, A.M.2
  • 3
    • 0035347390 scopus 로고    scopus 로고
    • Heart rate and performance parameters in cyclists
    • Atkinson G, Nevill AM. Heart rate and performance parameters in cyclists (letter to the editor). Med Sci Sports Exerc 2001; 33: 852
    • (2001) Med Sci Sports Exerc , vol.33 , pp. 852
    • Atkinson, G.1    Nevill, A.M.2
  • 4
    • 0034851804 scopus 로고    scopus 로고
    • Selected issues in the design and analysis of sport performance research
    • Atkinson G, Nevill AM. Selected issues in the design and analysis of sport performance research. J Sports Sci 2001; 19: 811 -827
    • (2001) J Sports Sci , vol.19 , pp. 811-827
    • Atkinson, G.1    Nevill, A.M.2
  • 6
    • 0029128946 scopus 로고
    • Evaluation of the Cosmed K2 telemetry system during exercise at moderate altitude
    • Bigard AX, Guezennec CY. Evaluation of the Cosmed K2 telemetry system during exercise at moderate altitude. Med Sci Sports Exerc 1995; 27: 1333-1338
    • (1995) Med Sci Sports Exerc , vol.27 , pp. 1333-1338
    • Bigard, A.X.1    Guezennec, C.Y.2
  • 7
    • 0038675123 scopus 로고    scopus 로고
    • Applying the right statistics: Analysis of measurement studies
    • Bland JM, Altman DG. Applying the right statistics: analysis of measurement studies. Ultrasound Obstet Gynecol 2003; 22: 85-93
    • (2003) Ultrasound Obstet Gynecol , vol.22 , pp. 85-93
    • Bland, J.M.1    Altman, D.G.2
  • 8
    • 0028791287 scopus 로고
    • Comparing methods of measurement: Why plotting difference against the standard method is misleading
    • Bland JM, Altman DG. Comparing methods of measurement: why plotting difference against the standard method is misleading. Lancet 1995; 346: 1085-1087
    • (1995) Lancet , vol.346 , pp. 1085-1087
    • Bland, J.M.1    Altman, D.G.2
  • 9
    • 0032884749 scopus 로고    scopus 로고
    • Measuring agreement in method comparison studies
    • Bland JM, Altman DG. Measuring agreement in method comparison studies. Stat Meth Med Res 1999; 8: 135-160
    • (1999) Stat Meth Med Res , vol.8 , pp. 135-160
    • Bland, J.M.1    Altman, D.G.2
  • 10
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; 1: 307-310
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 11
    • 0036514920 scopus 로고    scopus 로고
    • Validity and reliability of three commercially available breath-by-breath respiratory systems
    • Carter J, Jeukendrup AE. Validity and reliability of three commercially available breath-by-breath respiratory systems. Eur J Appl Physiol 2002; 86: 435-441
    • (2002) Eur J Appl Physiol , vol.86 , pp. 435-441
    • Carter, J.1    Jeukendrup, A.E.2
  • 12
    • 0028012078 scopus 로고
    • Evaluation of the Cosmed K2 portable telemetric oxygen uptake analyser
    • Crandall CG, Taylor SL, Raven PB. Evaluation of the Cosmed K2 portable telemetric oxygen uptake analyser. Med Sci Sports Exerc 1994; 26: 108-111
    • (1994) Med Sci Sports Exerc , vol.26 , pp. 108-111
    • Crandall, C.G.1    Taylor, S.L.2    Raven, P.B.3
  • 13
    • 0001983326 scopus 로고
    • Direct determination of aerobic power
    • Maud PJ, Foster C (eds). Champaign: Human Kinetics
    • Davis JA. Direct determination of aerobic power. In: Maud PJ, Foster C (eds). Physiological Assessment of Human Fitness. Champaign: Human Kinetics, 1995: 9-17
    • (1995) Physiological Assessment of Human Fitness , pp. 9-17
    • Davis, J.A.1
  • 14
    • 0037711917 scopus 로고    scopus 로고
    • Comparative analysis of the Cosmed Quark b2 and K4b2 gas analysis systems during submaximal exercise
    • Eisenmann JC, Brisko N, Shadrick D, Welsh S. Comparative analysis of the Cosmed Quark b2 and K4b2 gas analysis systems during submaximal exercise. J Sports Med Phys Fit 2003; 43: 150-155
    • (2003) J Sports Med Phys Fit , vol.43 , pp. 150-155
    • Eisenmann, J.C.1    Brisko, N.2    Shadrick, D.3    Welsh, S.4
  • 16
    • 0014250114 scopus 로고
    • Water-vapor pressure of end-tidal air of normals and chronic bronchitics
    • Green ID, Nesarajah MS. Water-vapor pressure of end-tidal air of normals and chronic bronchitics. J Appl Physiol 1968; 24: 229-232
    • (1968) J Appl Physiol , vol.24 , pp. 229-232
    • Green, I.D.1    Nesarajah, M.S.2
  • 17
    • 0030880253 scopus 로고    scopus 로고
    • The Cosmed K4 telemetry system as an accurate device for oxygen uptake measurements during exercise
    • Hausswirth C, Bigard AX, LeChevalier JM. The Cosmed K4 telemetry system as an accurate device for oxygen uptake measurements during exercise. Int J Sports Med 1997; 18: 449-453
    • (1997) Int J Sports Med , vol.18 , pp. 449-453
    • Hausswirth, C.1    Bigard, A.X.2    Lechevalier, J.M.3
  • 19
    • 0344629623 scopus 로고    scopus 로고
    • 2 measurement and implications for determination of recovery from running
    • 2 measurement and implications for determination of recovery from running. J Sports Sci 1997; 15: 30
    • (1997) J Sports Sci , vol.15 , pp. 30
    • James, D.V.B.1    Doust, J.H.2
  • 20
    • 0031991620 scopus 로고    scopus 로고
    • Reproducibility and validity of physiological parameters measured in cyclists riding on racing bikes placed on a stationary magnetic brake
    • Jensen K, Johansen L. Reproducibility and validity of physiological parameters measured in cyclists riding on racing bikes placed on a stationary magnetic brake. Scand J Med Sci Sports 1998; 8: 1-6
    • (1998) Scand J Med Sci Sports , vol.8 , pp. 1-6
    • Jensen, K.1    Johansen, L.2
  • 22
    • 0026616957 scopus 로고
    • Reliability of measurement of oxygen uptake by a portable telemetric system
    • Kawakami Y, Nozaki D, Matsuo A, Fukunaga T. Reliability of measurement of oxygen uptake by a portable telemetric system. Eur J Appl Physiol 1992; 65: 409-414
    • (1992) Eur J Appl Physiol , vol.65 , pp. 409-414
    • Kawakami, Y.1    Nozaki, D.2    Matsuo, A.3    Fukunaga, T.4
  • 24
    • 0002572034 scopus 로고
    • Measurement of pulmonary gas exchange
    • Maud PJ, Foster C (eds). Champaign: Human Kinetics
    • Lamarra N, Whipp B. Measurement of pulmonary gas exchange. In: Maud PJ, Foster C (eds). Physiological Assessment of Human Fitness. Champaign: Human Kinetics, 1995: 19-35
    • (1995) Physiological Assessment of Human Fitness , pp. 19-35
    • Lamarra, N.1    Whipp, B.2
  • 25
    • 0027615995 scopus 로고
    • Validity and reliability of the Cosmed K2 to measure oxygen uptake
    • Lothian F, Farrally MR, Mahoney C. Validity and reliability of the Cosmed K2 to measure oxygen uptake. Can J Appl Physiol 1993; 18: 197-206
    • (1993) Can J Appl Physiol , vol.18 , pp. 197-206
    • Lothian, F.1    Farrally, M.R.2    Mahoney, C.3
  • 27
    • 0030615216 scopus 로고    scopus 로고
    • Comparing methods of measurement
    • Ludbrook J. Comparing methods of measurement. Clin Exp Pharm Physiol 1997; 24: 193-203
    • (1997) Clin Exp Pharm Physiol , vol.24 , pp. 193-203
    • Ludbrook, J.1
  • 28
    • 0034785831 scopus 로고    scopus 로고
    • Automated metabolic gas analysis systems: A review
    • Macfarlane DJ. Automated metabolic gas analysis systems: a review. Sports Med 2001; 31: 841-861
    • (2001) Sports Med , vol.31 , pp. 841-861
    • Macfarlane, D.J.1
  • 30
    • 0035207994 scopus 로고    scopus 로고
    • Reliability of gas exchange measurements from two different spiroergometry systems
    • Meyer T, Georg T, Becker C, Kindermann W. Reliability of gas exchange measurements from two different spiroergometry systems. Int J Sports Med 2001; 22: 593-597
    • (2001) Int J Sports Med , vol.22 , pp. 593-597
    • Meyer, T.1    Georg, T.2    Becker, C.3    Kindermann, W.4
  • 32
    • 0025051920 scopus 로고
    • Effect of sampling on variability and plateau in oxygen uptake
    • Myers J, Walsh M, Sullivan M, Froelicher V. Effect of sampling on variability and plateau in oxygen uptake. J Appl Physiol 1990; 68: 404-410
    • (1990) J Appl Physiol , vol.68 , pp. 404-410
    • Myers, J.1    Walsh, M.2    Sullivan, M.3    Froelicher, V.4
  • 33
    • 0030697403 scopus 로고    scopus 로고
    • Assessing agreement between measurements recorded on a ratio scale in sports medicine and sports science
    • Nevill AM, Atkinson G. Assessing agreement between measurements recorded on a ratio scale in sports medicine and sports science. Br J Sports Med 1997; 31: 314-318
    • (1997) Br J Sports Med , vol.31 , pp. 314-318
    • Nevill, A.M.1    Atkinson, G.2
  • 35
    • 0027401060 scopus 로고
    • Oxygen-consumption using the K2 telemetry system and a metabolic cart
    • Peel C, Utsey C. Oxygen-consumption using the K2 telemetry system and a metabolic cart. Med Sci Sports Exerc 1993; 25: 396-400
    • (1993) Med Sci Sports Exerc , vol.25 , pp. 396-400
    • Peel, C.1    Utsey, C.2
  • 36
    • 0035007392 scopus 로고    scopus 로고
    • Validation of a computerised metabolic measurement system (Oxycon-Pro) during low and high intensity exercise
    • Rietjens GJWM, Kuipers H, Kester ADM, Keizer HA. Validation of a computerised metabolic measurement system (Oxycon-Pro) during low and high intensity exercise. Int J Sports Med 2001; 22: 291-294
    • (2001) Int J Sports Med , vol.22 , pp. 291-294
    • Rietjens, G.J.W.M.1    Kuipers, H.2    Kester, A.D.M.3    Keizer, H.A.4
  • 37
  • 41
    • 0036089865 scopus 로고    scopus 로고
    • Validity of pulse oximetry during maximal exercise in normoxia, hypoxia and hyperoxia
    • Yamaya Y, Bogaard HJ, Wagner PD, Niizeki K, Hopkins SR. Validity of pulse oximetry during maximal exercise in normoxia, hypoxia and hyperoxia. J Appl Physiol 2002; 92: 162-168
    • (2002) J Appl Physiol , vol.92 , pp. 162-168
    • Yamaya, Y.1    Bogaard, H.J.2    Wagner, P.D.3    Niizeki, K.4    Hopkins, S.R.5
  • 42
    • 0023628720 scopus 로고
    • Turbine flowmeter vs. Fleish pneumotachometer: A comparative study for exercise testing
    • Yen MP, Adams TD, Gardner RM, Yanowitz FG. Turbine flowmeter vs. Fleish pneumotachometer: a comparative study for exercise testing. J Appl Physiol 1987; 63: 1289-1295
    • (1987) J Appl Physiol , vol.63 , pp. 1289-1295
    • Yen, M.P.1    Adams, T.D.2    Gardner, R.M.3    Yanowitz, F.G.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.