메뉴 건너뛰기




Volumn 23, Issue 1, 2005, Pages 75-81

To smooth or not to smooth? ROC analysis of perfusion fMRI data

Author keywords

Arterial spin labeling (ASL); Cerebral blood flow (CBF); Functional brain imaging; Receiver operator characteristic (ROC); Spatial smoothing; Temporal smoothing

Indexed keywords

ACCURACY; ADULT; AMPLITUDE MODULATION; ARTICLE; DATA ANALYSIS; EVALUATION; FEMALE; FUNCTIONAL MAGNETIC RESONANCE IMAGING; HUMAN; HUMAN EXPERIMENT; INTERMETHOD COMPARISON; MALE; MEASUREMENT; METHODOLOGY; NORMAL HUMAN; OXYGEN BLOOD LEVEL; PERFUSION; PRIORITY JOURNAL; SIGNAL TRANSDUCTION; SIMULATION; SPATIAL DISCRIMINATION; STATISTICAL ANALYSIS;

EID: 13944256632     PISSN: 0730725X     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.mri.2004.11.009     Document Type: Article
Times cited : (47)

References (37)
  • 1
    • 0030733807 scopus 로고    scopus 로고
    • Empirical analyses of BOLD fMRI statistics: I. Spatially unsmoothed data collected under null-hypothesis conditions
    • E. Zarahn, G.K. Aguirre, and M. D'Esposito Empirical analyses of BOLD fMRI statistics: I. Spatially unsmoothed data collected under null-hypothesis conditions Neuroimage 5 3 1997 179 197
    • (1997) Neuroimage , vol.5 , Issue.3 , pp. 179-197
    • Zarahn, E.1    Aguirre, G.K.2    D'Esposito, M.3
  • 3
    • 0034952064 scopus 로고    scopus 로고
    • High-resolution fMRI using multislice partial k-space GR-EPI with cubic voxels
    • J.S. Hyde, B.B. Biswal, and A. Jesmanowicz High-resolution fMRI using multislice partial k-space GR-EPI with cubic voxels Magn. Reson. Med. 46 1 2001 114 125
    • (2001) Magn. Reson. Med. , vol.46 , Issue.1 , pp. 114-125
    • Hyde, J.S.1    Biswal, B.B.2    Jesmanowicz, A.3
  • 8
    • 0035212159 scopus 로고    scopus 로고
    • Temporal autocorrelation in univariate linear modeling of FMRI data
    • M.W. Woolrich, B.D. Ripley, M. Brady, and S.M. Smith Temporal autocorrelation in univariate linear modeling of FMRI data Neuroimage 14 6 2001 1370 1386
    • (2001) Neuroimage , vol.14 , Issue.6 , pp. 1370-1386
    • Woolrich, M.W.1    Ripley, B.D.2    Brady, M.3    Smith, S.M.4
  • 9
    • 0029096148 scopus 로고
    • Analysis of fMRI time-series revisited - Again
    • K.J. Worsley, and K.J. Friston Analysis of fMRI time-series revisited - again Neuroimage 2 1995 173 182
    • (1995) Neuroimage , vol.2 , pp. 173-182
    • Worsley, K.J.1    Friston, K.J.2
  • 10
    • 0002207082 scopus 로고    scopus 로고
    • Perfusion fMRI with arterial spin labeling (ASL)
    • C.T.W. Moonen P.A. Bandettini Springer Heidelberg
    • J.A. Detre, and D.C. Alsop Perfusion fMRI with arterial spin labeling (ASL) C.T.W. Moonen P.A. Bandettini Functional MRI 1999 Springer Heidelberg 47 62
    • (1999) Functional MRI , pp. 47-62
    • Detre, J.A.1    Alsop, D.C.2
  • 11
    • 0003051758 scopus 로고    scopus 로고
    • Potential and pitfalls of arterial spin labeling based perfusion imaging techniques for MRI
    • C.T.W. Moonen P.A. Bandettini Springer Heidelberg
    • E.C. Wong Potential and pitfalls of arterial spin labeling based perfusion imaging techniques for MRI C.T.W. Moonen P.A. Bandettini Functional MRI 1999 Springer Heidelberg 63 69
    • (1999) Functional MRI , pp. 63-69
    • Wong, E.C.1
  • 13
    • 0036236505 scopus 로고    scopus 로고
    • Technical aspects and utilities of fMRI using BOLD and ASL
    • J.A. Detre, and J. Wang Technical aspects and utilities of fMRI using BOLD and ASL Clin. Neurophysiol. 113 2002 621 634
    • (2002) Clin. Neurophysiol. , vol.113 , pp. 621-634
    • Detre, J.A.1    Wang, J.2
  • 14
    • 0035845504 scopus 로고    scopus 로고
    • Localized cerebral blood flow response at submillimeter columnar resolution
    • T.Q. Duong, D.K. Kim, K. Ugurbil, and S.G. Kim Localized cerebral blood flow response at submillimeter columnar resolution Proc. Natl. Acad. Sci. U. S. A. 98 2001 10904 10909
    • (2001) Proc. Natl. Acad. Sci. U. S. A. , vol.98 , pp. 10904-10909
    • Duong, T.Q.1    Kim, D.K.2    Ugurbil, K.3    Kim, S.G.4
  • 15
    • 0033937960 scopus 로고    scopus 로고
    • Comparison of simultaneously measured perfusion and BOLD signal increases during brain activation with T(1)-based tissue identification
    • W.M. Luh, E.C. Wong, P.A. Bandettini, B.D. Ward, and J.S. Hyde Comparison of simultaneously measured perfusion and BOLD signal increases during brain activation with T(1)-based tissue identification Magn. Reson. Med. 44 1 2000 137 143
    • (2000) Magn. Reson. Med. , vol.44 , Issue.1 , pp. 137-143
    • Luh, W.M.1    Wong, E.C.2    Bandettini, P.A.3    Ward, B.D.4    Hyde, J.S.5
  • 16
    • 1242292426 scopus 로고    scopus 로고
    • Reduced susceptibility effect in perfusion fMRI using single-shot spin-echo EPI acquisitions
    • J. Wang, L. Li, A.C. Roc, D.C. Alsop, K. Tang, and N. Butler Reduced susceptibility effect in perfusion fMRI using single-shot spin-echo EPI acquisitions Magn. Reson. Imaging 22 1 2004 1 7
    • (2004) Magn. Reson. Imaging , vol.22 , Issue.1 , pp. 1-7
    • Wang, J.1    Li, L.2    Roc, A.C.3    Alsop, D.C.4    Tang, K.5    Butler, N.6
  • 17
    • 0042425789 scopus 로고    scopus 로고
    • Empirical analyses of null-hypothesis perfusion fMRI data at 1.5 and 4T
    • J. Wang, G.K. Aguirre, D.Y. Kimberg, and J.A. Detre Empirical analyses of null-hypothesis perfusion fMRI data at 1.5 and 4T Neuroimage 19 4 2003 1449 1462
    • (2003) Neuroimage , vol.19 , Issue.4 , pp. 1449-1462
    • Wang, J.1    Aguirre, G.K.2    Kimberg, D.Y.3    Detre, J.A.4
  • 18
    • 0036338610 scopus 로고    scopus 로고
    • Experimental design and the relative sensitivity of BOLD and perfusion fMRI
    • G.K. Aguirre, J.A. Detre, E. Zarahn, and D.C. Alsop Experimental design and the relative sensitivity of BOLD and perfusion fMRI Neuroimage 15 3 2002 488 500
    • (2002) Neuroimage , vol.15 , Issue.3 , pp. 488-500
    • Aguirre, G.K.1    Detre, J.A.2    Zarahn, E.3    Alsop, D.C.4
  • 19
    • 0033831770 scopus 로고    scopus 로고
    • A CBF-based event-related brain activation paradigm: Characterization of impulse-response function and comparison to BOLD
    • Y. Yang, W. Engelien, H. Pan, S. Xu, D.A. Silbersweig, and E. Stern A CBF-based event-related brain activation paradigm: characterization of impulse-response function and comparison to BOLD Neuroimage 12 3 2000 287 297
    • (2000) Neuroimage , vol.12 , Issue.3 , pp. 287-297
    • Yang, Y.1    Engelien, W.2    Pan, H.3    Xu, S.4    Silbersweig, D.A.5    Stern, E.6
  • 20
    • 0034016168 scopus 로고    scopus 로고
    • Comparison of the temporal response in perfusion and BOLD-based event-related functional MRI
    • H.L. Liu, Y. Pu, L.D. Nickerson, Y. Liu, P.T. Fox, and J.H. Gao Comparison of the temporal response in perfusion and BOLD-based event-related functional MRI Magn. Reson. Med. 43 5 2000 768 772
    • (2000) Magn. Reson. Med. , vol.43 , Issue.5 , pp. 768-772
    • Liu, H.L.1    Pu, Y.2    Nickerson, L.D.3    Liu, Y.4    Fox, P.T.5    Gao, J.H.6
  • 22
    • 0026781154 scopus 로고
    • A three-dimensional statistical analysis for CBF activation studies in human brain
    • K.J. Worsley, A.C. Evans, S. Marrett, and P. Neelin A three-dimensional statistical analysis for CBF activation studies in human brain J. Cereb. Blood Flow Metab. 12 6 1992 900 918
    • (1992) J. Cereb. Blood Flow Metab. , vol.12 , Issue.6 , pp. 900-918
    • Worsley, K.J.1    Evans, A.C.2    Marrett, S.3    Neelin, P.4
  • 23
    • 0028246480 scopus 로고
    • Enhanced detection in brain activation maps using a multifiltering approach
    • J.B. Poline, and B.M. Mazoyer Enhanced detection in brain activation maps using a multifiltering approach J. Cereb. Blood Flow Metab. 14 4 1994 639 642
    • (1994) J. Cereb. Blood Flow Metab. , vol.14 , Issue.4 , pp. 639-642
    • Poline, J.B.1    Mazoyer, B.M.2
  • 24
    • 0030831697 scopus 로고    scopus 로고
    • Empirical analyses of BOLD fMRI statistics: II. Spatially smoothed data collected under null-hypothesis and experimental conditions
    • G.K. Aguirre, E. Zarahn, and M. D'Esposito Empirical analyses of BOLD fMRI statistics: II. Spatially smoothed data collected under null-hypothesis and experimental conditions Neuroimage 5 3 1997 199 212
    • (1997) Neuroimage , vol.5 , Issue.3 , pp. 199-212
    • Aguirre, G.K.1    Zarahn, E.2    D'Esposito, M.3
  • 25
    • 0018079655 scopus 로고
    • Basic principle of ROC analysis
    • C.E. Metz Basic principle of ROC analysis Semin. Nucl. Med VIII 4 1978 283 298
    • (1978) Semin. Nucl. Med , vol.8 , Issue.4 , pp. 283-298
    • Metz, C.E.1
  • 26
    • 0032807513 scopus 로고    scopus 로고
    • ROC analysis of statistical methods used in functional MRI: Individual subjects
    • P. Skudlarski, R.T. Constable, and J.C. Gore ROC analysis of statistical methods used in functional MRI: individual subjects Neuroimage 9 1999 311 329
    • (1999) Neuroimage , vol.9 , pp. 311-329
    • Skudlarski, P.1    Constable, R.T.2    Gore, J.C.3
  • 27
    • 0029025207 scopus 로고
    • An ROC approach for evaluating functional brain MR imaging and postprocessing protocols
    • R.T. Constable, P. Skudlarski, and J.C. Gore An ROC approach for evaluating functional brain MR imaging and postprocessing protocols Magn. Reson. Med. 34 1 1995 57 64
    • (1995) Magn. Reson. Med. , vol.34 , Issue.1 , pp. 57-64
    • Constable, R.T.1    Skudlarski, P.2    Gore, J.C.3
  • 28
    • 0036325034 scopus 로고    scopus 로고
    • Comparison of quantitative perfusion imaging using arterial spin labeling at 1.5 and 4.0 Tesla
    • J. Wang, D.C. Alsop, L. Li, J. Listerud, J.B. Gonzalez-At, and M.D. Schnall Comparison of quantitative perfusion imaging using arterial spin labeling at 1.5 and 4.0 Tesla Magn. Reson. Med. 48 2 2002 242 254
    • (2002) Magn. Reson. Med. , vol.48 , Issue.2 , pp. 242-254
    • Wang, J.1    Alsop, D.C.2    Li, L.3    Listerud, J.4    Gonzalez-At, J.B.5    Schnall, M.D.6
  • 29
    • 0029151256 scopus 로고
    • Quantification of relative cerebral blood flow change by flow-sensitive alternating inversion recovery (FAIR) technique: Application to functional mapping
    • S.G. Kim Quantification of relative cerebral blood flow change by flow-sensitive alternating inversion recovery (FAIR) technique: application to functional mapping Magn. Reson. Med. 34 1995 293 301
    • (1995) Magn. Reson. Med. , vol.34 , pp. 293-301
    • Kim, S.G.1
  • 30
    • 0032749944 scopus 로고    scopus 로고
    • Multislice perfusion imaging in human brain using the C-FOCI inversion pulse: Comparison with hyperbolic secant
    • M.N. Yongbi, Y. Yang, J.A. Frank, and J.H. Duyn Multislice perfusion imaging in human brain using the C-FOCI inversion pulse: comparison with hyperbolic secant Magn. Reson. Med. 42 6 1999 1098 1105
    • (1999) Magn. Reson. Med. , vol.42 , Issue.6 , pp. 1098-1105
    • Yongbi, M.N.1    Yang, Y.2    Frank, J.A.3    Duyn, J.H.4
  • 31
    • 0031966050 scopus 로고    scopus 로고
    • Quantitative imaging of perfusion using a single subtraction (QUIPSS and QUIPSS II)
    • E.C. Wong, R.B. Buxton, and L.R. Frank Quantitative imaging of perfusion using a single subtraction (QUIPSS and QUIPSS II) Magn. Reson. Med. 39 5 1998 702 708
    • (1998) Magn. Reson. Med. , vol.39 , Issue.5 , pp. 702-708
    • Wong, E.C.1    Buxton, R.B.2    Frank, L.R.3
  • 34
    • 0030725989 scopus 로고    scopus 로고
    • Implementation of quantitative perfusion imaging techniques for functional brain mapping using pulsed arterial spin labeling
    • E.C. Wong, R.B. Buxton, and L.R. Frank Implementation of quantitative perfusion imaging techniques for functional brain mapping using pulsed arterial spin labeling NMR Biomed. 10 4-5 1997 237 249
    • (1997) NMR Biomed. , vol.10 , Issue.45 , pp. 237-249
    • Wong, E.C.1    Buxton, R.B.2    Frank, L.R.3
  • 35
    • 0032213559 scopus 로고    scopus 로고
    • The variability of human BOLD hemodynamic responses
    • G.K. Aguirre, E. Zarahn, and M. D'Esposito The variability of human BOLD hemodynamic responses Neuroimage 8 1998 360 369
    • (1998) Neuroimage , vol.8 , pp. 360-369
    • Aguirre, G.K.1    Zarahn, E.2    D'Esposito, M.3
  • 37
    • 0033780827 scopus 로고    scopus 로고
    • Turbo ASL: Arterial spin labeling with higher SNR and temporal resolution
    • E.C. Wong, W.M. Luh, and T.T. Liu Turbo ASL: arterial spin labeling with higher SNR and temporal resolution Magn. Reson. Med. 44 4 2000 511 515
    • (2000) Magn. Reson. Med. , vol.44 , Issue.4 , pp. 511-515
    • Wong, E.C.1    Luh, W.M.2    Liu, T.T.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.