Placement of pacemaker leads via the extrathoracic subclavian vein guided by fluoroscopy and venography in the oblique projection

Author keywords

Extrathoracic subclavian vein puncture; Fluoroscopy; Oblique projection; Pacemaker; Venography

Indexed keywords

ADULT; AGED; ARTICLE; ARTIFICIAL HEART PACEMAKER; CLAVICLE; CLINICAL ARTICLE; CONTROLLED STUDY; FEMALE; FLUOROSCOPY; FOLLOW UP; HEART PACING; HEMATOTHORAX; HUMAN; IMPLANTATION; LIGAMENT; MALE; MEDICAL INSTRUMENTATION; METHODOLOGY; MUSCLE; NEEDLE; PHLEBOGRAPHY; PNEUMOTHORAX; PRIORITY JOURNAL; RADIATION BEAM; RIB; RISK ASSESSMENT; SOFT TISSUE INJURY; SUBCLAVIAN VEIN; THORAX; VEIN PUNCTURE; X RAY;

EID: 13844310752     PISSN: 09108327     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00380-004-0797-1     Document Type: Article
Times cited : (17)

References (9)
  • 1
    • 0024556859 scopus 로고
    • Pacemaker implantation complication rates: An analysis of some contributiong factors
    • Parsonnet V, Bernstein AD, Lindsay B (1989) Pacemaker implantation complication rates: An analysis of some contributiong factors. J Am Coll Cardiol 13:917-921
    • (1989) J. Am. Coll. Cardiol. , vol.13 , pp. 917-921
    • Parsonnet, V.1    Bernstein, A.D.2    Lindsay, B.3
  • 3
    • 0026550621 scopus 로고
    • Safe introducer technique for pacemaker lead implantation
    • Byrd CL (1992) Safe introducer technique for pacemaker lead implantation. PACE 15:262-267
    • (1992) PACE , vol.15 , pp. 262-267
    • Byrd, C.L.1
  • 4
    • 0027227662 scopus 로고
    • Clinical experience with the extrathoracic introducer technique
    • Byrd CL (1993) Clinical experience with the extrathoracic introducer technique. PACE 16:1781-1784
    • (1993) PACE , vol.16 , pp. 1781-1784
    • Byrd, C.L.1
  • 5
    • 0027285289 scopus 로고
    • Anatomical mechanisms explaining damage to pacemaker leads, defibrillator leads, and failure of central venous catheters adjacent to the sternoclavicular joint
    • Magney JE, Flynn DM, Parsons JA, Staplin DH, Chin-Purcell MV, Milstein S, Hunter DW (1993) Anatomical mechanisms explaining damage to pacemaker leads, defibrillator leads, and failure of central venous catheters adjacent to the sternoclavicular joint. PACE 16:445-457
    • (1993) PACE , vol.16 , pp. 445-457
    • Magney, J.E.1    Flynn, D.M.2    Parsons, J.A.3    Staplin, D.H.4    Chin-Purcell, M.V.5    Milstein, S.6    Hunter, D.W.7
  • 6
    • 0027442941 scopus 로고
    • A new approach to percutaneous subclavian venipuncture to avoid lead fracture or central venous catheter occlusion
    • Magney JE, David H, Staplin DH, Flynn DM, Hunter DW (1993) A new approach to percutaneous subclavian venipuncture to avoid lead fracture or central venous catheter occlusion. PACE 16:2133-2142
    • (1993) PACE , vol.16 , pp. 2133-2142
    • Magney, J.E.1    David, H.2    Staplin, D.H.3    Flynn, D.M.4    Hunter, D.W.5
  • 8
    • 0035040315 scopus 로고    scopus 로고
    • Prospective randomized comparison of the safety and effectiveness of placement of endocardial pacemaker and defibrillator leads using the extrathoracic subclavian vein guided by contrast venography versus the cephalic approach
    • Calkins H, Ramza BM, Brinker J, Atiga W, Donahue K, Nash E, Taylor E, Halperin H, Lawrence JH, Tomaselli G, Berger RD (2001) Prospective randomized comparison of the safety and effectiveness of placement of endocardial pacemaker and defibrillator leads using the extrathoracic subclavian vein guided by contrast venography versus the cephalic approach. PACE 24:456-464
    • (2001) PACE , vol.24 , pp. 456-464
    • Calkins, H.1    Ramza, B.M.2    Brinker, J.3    Atiga, W.4    Donahue, K.5    Nash, E.6    Taylor, E.7    Halperin, H.8    Lawrence, J.H.9    Tomaselli, G.10    Berger, R.D.11
  • 9
    • 0029024076 scopus 로고
    • Doppler guided extrathoracic introducer insertion
    • Fyke FE (1995) Doppler guided extrathoracic introducer insertion. PACE 18:1017-1021
    • (1995) PACE , vol.18 , pp. 1017-1021
    • Fyke, F.E.1