메뉴 건너뛰기




Volumn 24, Issue 4 I, 2001, Pages 456-464

Prospective randomized comparison of the safety and effectiveness of placement of endocardial pacemaker and defibrillator leads using the extrathoracic subclavian vein guided by contrast venography versus the cephalic approach

Author keywords

Endocardial lead; Implantable defibrillator; Pacemaker; Subclavian vein

Indexed keywords

ADULT; AGED; ARTICLE; ARTIFICIAL HEART PACEMAKER; BLEEDING; BRACHIOCEPHALIC VEIN; CLINICAL TRIAL; CONTRAST ENHANCEMENT; DEFIBRILLATOR; ENDOCARDIUM; FEMALE; HUMAN; INCIDENCE; INTERMETHOD COMPARISON; MAJOR CLINICAL STUDY; MALE; OPERATION DURATION; PHLEBOGRAPHY; POSTOPERATIVE COMPLICATION; RANDOMIZATION; SAFETY; SUBCLAVIAN VEIN; SURGICAL TECHNIQUE;

EID: 0035040315     PISSN: 01478389     EISSN: None     Source Type: Journal    
DOI: 10.1046/j.1460-9592.2001.00456.x     Document Type: Article
Times cited : (101)

References (44)
  • 16
    • 0032005226 scopus 로고    scopus 로고
    • Subcutaneous single-incision implantation of cardioverter-defibrillators under local anesthesia by electrophysiologists in the electrophysiology laboratory
    • (1998) Am J Cardiol , vol.81 , pp. 302-305
    • Rugge, F.P.1    Savalle, L.H.2    Schalij, M.J.3
  • 22
    • 0000821007 scopus 로고
    • Pacing lead fracture, a previously unknown complication of subclavian stick
    • (1988) PACE , vol.11 , pp. 855
    • Stokes, K.1    McVenes, R.2
  • 25
    • 0027285289 scopus 로고
    • Anatomical mechanisms explaining damage to pacemaker leads, defibrillator leads, and failure of central venous catheters adjacent to the sternoclavicular joint
    • (1993) PACE , vol.36 , pp. 445-457
    • Magney, J.E.1    Flynn, D.M.2    Parsons, J.A.3
  • 27
    • 0026550621 scopus 로고
    • Safe introducer technique for pacemaker lead implantation
    • (1992) PACE , vol.15 , pp. 262-269
    • Byrd, C.L.1
  • 28
    • 0027227662 scopus 로고
    • Clinical experience with the extrathoracic introducer insertion technique
    • (1993) PACE , vol.16 , pp. 1781-1784
    • Byrd, C.L.1
  • 29
    • 0028085655 scopus 로고
    • The role of sonography in the placement and management of jugular and subclavian central venous catheters
    • (1994) AJR Am J Roentgenol , vol.163 , pp. 291-295
    • Skolnick, M.L.1
  • 30
    • 0029024076 scopus 로고
    • Doppler guided extrathoracic introducer insertion
    • (1995) PACE , vol.18 , pp. 1017-1021
    • Fyke, E.F.1
  • 33
    • 0032982807 scopus 로고    scopus 로고
    • The cephalic vein cutdown versus subclavian puncture for pacemaker/ICD lead implantation
    • (1999) PACE , vol.22 , pp. 695-697
    • Parsonnet, V.1    Roelke, M.2
  • 35
    • 0029301487 scopus 로고
    • Endocardial pacing leads: The good, the bad, and the ugly
    • (1995) PACE , vol.18 , Issue.PART I , pp. 953-954
    • Brinker, J.A.1
  • 41
    • 0022742569 scopus 로고
    • Subclavian puncture for pacemaker lead placement
    • (1986) PACE , vol.9 , pp. 467
    • Furman, S.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.