메뉴 건너뛰기




Volumn 40, Issue 1, 2005, Pages 59-79

The acoustic emission technique in orthopaedics - A review

Author keywords

Acoustic emission; Hip replacement; Implant; Orthopaedics

Indexed keywords

BONE; IMPLANTS (SURGICAL); INFORMATION DISSEMINATION; JOINTS (ANATOMY); ORTHOPEDICS; PATIENT MONITORING; PHOTOGRAPHIC FILMS; POLYMETHYL METHACRYLATES; PROSTHETICS;

EID: 13644282972     PISSN: 03093247     EISSN: None     Source Type: Journal    
DOI: 10.1243/030932405X7638     Document Type: Review
Times cited : (30)

References (90)
  • 1
    • 84855618401 scopus 로고    scopus 로고
    • National total hip replacement outcome study
    • The Royal College of Surgeons of England, London
    • Gregg, P. J., and Reeves, D. C. National total hip replacement outcome study. Final Report to the Department of Health, 2000 (The Royal College of Surgeons of England, London).
    • (2000) Final Report to the Department of Health
    • Gregg, P.J.1    Reeves, D.C.2
  • 3
    • 0032723224 scopus 로고    scopus 로고
    • Outcome of Charnley total hip replacement across a single health region in England - The results at five years from a regional hip register
    • Fender, D., Harper, W. M., and Gregg, P. J. Outcome of Charnley total hip replacement across a single health region in England - the results at five years from a regional hip register. J. Bone Jt Surg. - Br. Vol., 1999, 81B(4), 577-581.
    • (1999) J. Bone Jt Surg. - Br. , vol.81 B , Issue.4 , pp. 577-581
    • Fender, D.1    Harper, W.M.2    Gregg, P.J.3
  • 4
    • 0027489640 scopus 로고
    • Mechanical failure in total hip arthroplasty with cement
    • Huiskes, R. Mechanical failure in total hip arthroplasty with cement. Current Orthop., 1993, 7, 239-247.
    • (1993) Current Orthop. , vol.7 , pp. 239-247
    • Huiskes, R.1
  • 5
    • 0027714838 scopus 로고
    • Microstructural pathway of fracture in poly(methyl methacrylate) bone-cement
    • Topoleski, L. D. T., Ducheyne, P., and Cuckler, J. M. Microstructural pathway of fracture in poly(methyl methacrylate) bone-cement. Biomaterials, 1993, 14(15), 1165-1172.
    • (1993) Biomaterials , vol.14 , Issue.15 , pp. 1165-1172
    • Topoleski, L.D.T.1    Ducheyne, P.2    Cuckler, J.M.3
  • 6
    • 0018687995 scopus 로고
    • Modes of failure of cemented stem-type femoral component, a radiographic analysis of loosening
    • Gruen, T. A., Gregory, M. S., McNiece, M., and Amstutz, H. C. Modes of failure of cemented stem-type femoral component, a radiographic analysis of loosening. Clin. Orthop. Related Res., 1979, 141, 17-27.
    • (1979) Clin. Orthop. Related Res. , vol.141 , pp. 17-27
    • Gruen, T.A.1    Gregory, M.S.2    McNiece, M.3    Amstutz, H.C.4
  • 7
    • 0035215251 scopus 로고    scopus 로고
    • Charnley total hip arthroplasty with use of improved cementing techniques - A minimum twenty-year follow-up study
    • Klapach, A. S., Callaghan, J. J., Goetz, D. D., Olejniczak, J. P., and Johnston, R. C. Charnley total hip arthroplasty with use of improved cementing techniques - a minimum twenty-year follow-up study. J. Bone Jt Surg. - Am. Vol., 2001, 83A(12), 1840-1848.
    • (2001) J. Bone Jt Surg. - Am. , vol.83 A , Issue.12 , pp. 1840-1848
    • Klapach, A.S.1    Callaghan, J.J.2    Goetz, D.D.3    Olejniczak, J.P.4    Johnston, R.C.5
  • 8
    • 0022491338 scopus 로고
    • Loosening of the femoral component after total hip-replacement -the thin black line and the sinking hip
    • Paterson, M., Fulford, P., and Denham, R. Loosening of the femoral component after total hip-replacement -the thin black line and the sinking hip. J. Bone Jt Surg. - Br. Vol., 1986, 68(3), 392-397.
    • (1986) J. Bone Jt Surg. - Br. , vol.68 , Issue.3 , pp. 392-397
    • Paterson, M.1    Fulford, P.2    Denham, R.3
  • 10
    • 0025388865 scopus 로고
    • A fractographic analysis of in vivo poly(methyl methacrylate) bone-cement failure mechanisms
    • Topoleski, L. D. T., Ducheyne, P., and Cuckler, J. M. A fractographic analysis of in vivo poly(methyl methacrylate) bone-cement failure mechanisms. J. Biomed. Mater. Res., 1990, 24(2), 135-154.
    • (1990) J. Biomed. Mater. Res. , vol.24 , Issue.2 , pp. 135-154
    • Topoleski, L.D.T.1    Ducheyne, P.2    Cuckler, J.M.3
  • 11
    • 0034997894 scopus 로고    scopus 로고
    • Accurate diagnosis of hip prosthesis loosening using a vibrational technique
    • Georgiou, A. P., and Cunningham, J. L. Accurate diagnosis of hip prosthesis loosening using a vibrational technique. Clin. Biomechanics, 2001, 16(4), 315-323.
    • (2001) Clin. Biomechanics , vol.16 , Issue.4 , pp. 315-323
    • Georgiou, A.P.1    Cunningham, J.L.2
  • 12
    • 0036316205 scopus 로고    scopus 로고
    • Reliability of detecting prosthesis/cement interface radiolucencies in total hip arthroplasty
    • Zhang, Y. D., Putnam, A. W., Heiner, A. D., Callaghan, J. J., and Brown, T. D. Reliability of detecting prosthesis/cement interface radiolucencies in total hip arthroplasty. J. Orthop. Res., 2002, 20(4), 683-687.
    • (2002) J. Orthop. Res. , vol.20 , Issue.4 , pp. 683-687
    • Zhang, Y.D.1    Putnam, A.W.2    Heiner, A.D.3    Callaghan, J.J.4    Brown, T.D.5
  • 13
    • 0141535276 scopus 로고    scopus 로고
    • The diagnostic value of digital subtraction arthrography and radionuclide bone scan in revision hip arthroplasty
    • Ovesen, O., Riegels-Nielsen, P., Lindequist, S., Jensen, I., Munkner, T., Torfing, T., and Marving, J. The diagnostic value of digital subtraction arthrography and radionuclide bone scan in revision hip arthroplasty. J. Arthroplasty, 2003, 18(6), 735-740.
    • (2003) J. Arthroplasty , vol.18 , Issue.6 , pp. 735-740
    • Ovesen, O.1    Riegels-Nielsen, P.2    Lindequist, S.3    Jensen, I.4    Munkner, T.5    Torfing, T.6    Marving, J.7
  • 14
    • 0030979071 scopus 로고    scopus 로고
    • The role of aspiration and contrast-enhanced arthrography in evaluating the uncemented hip arthroplasty
    • Cheung, A., Lachiewicz, P. F., and Renner, J. B. The role of aspiration and contrast-enhanced arthrography in evaluating the uncemented hip arthroplasty. Am. J. Roentgenology, 1997, 168(5), 1305-1309.
    • (1997) Am. J. Roentgenology , vol.168 , Issue.5 , pp. 1305-1309
    • Cheung, A.1    Lachiewicz, P.F.2    Renner, J.B.3
  • 15
    • 0031463684 scopus 로고    scopus 로고
    • Plain radiographs and radiographic arthrograms in the assessment of prosthetic hip component loosening
    • Greiner, B., Braun, M., and Becker, W. Plain radiographs and radiographic arthrograms in the assessment of prosthetic hip component loosening. Z. für Orthopadie und Ihre Grenzgebiete, 1997, 135(4), 292-296.
    • (1997) Z. für Orthopadie und Ihre Grenzgebiete , vol.135 , Issue.4 , pp. 292-296
    • Greiner, B.1    Braun, M.2    Becker, W.3
  • 16
    • 0027284677 scopus 로고
    • Evaluation of painful hip arthroplasties - Are technetium bone scans necessary?
    • Lieberman, J. R., Huo, M. H., Schneider, R., Salvati, E. A., and Rodi, S. Evaluation of painful hip arthroplasties - are technetium bone scans necessary? J. Bone Jt Surg. -Br. Vol., 1993, 75(3), 475-478.
    • (1993) J. Bone Jt Surg. -Br. , vol.75 , Issue.3 , pp. 475-478
    • Lieberman, J.R.1    Huo, M.H.2    Schneider, R.3    Salvati, E.A.4    Rodi, S.5
  • 17
    • 2642611122 scopus 로고    scopus 로고
    • Evaluation of imaging in loosening of hip arthroplasty in 326 consecutive cases
    • Pfahler, M., Schidlo, C., and Refior, H. J. Evaluation of imaging in loosening of hip arthroplasty in 326 consecutive cases. Archives of Orthop. Trauma Surg., 1998, 117(4-5), 205-207.
    • (1998) Archives of Orthop. Trauma Surg. , vol.117 , Issue.4-5 , pp. 205-207
    • Pfahler, M.1    Schidlo, C.2    Refior, H.J.3
  • 18
    • 0030271435 scopus 로고    scopus 로고
    • Vibration analysis in the detection of total hip prosthetic loosening
    • Li, P. L. S., Jones, N. B., and Gregg, P. J. Vibration analysis in the detection of total hip prosthetic loosening. Med. Engng Physics, 1996, 18(7), 596-600.
    • (1996) Med. Engng Physics , vol.18 , Issue.7 , pp. 596-600
    • Li, P.L.S.1    Jones, N.B.2    Gregg, P.J.3
  • 19
    • 13644272942 scopus 로고    scopus 로고
    • Detection of hip stem loosening using vibration analysis
    • The Hague, The Netherlands, 15-18 September
    • Denayer, I., and Van der Perre, G. Detection of hip stem loosening using vibration analysis. In European Society of Biomaterials Meeting, The Hague, The Netherlands, 15-18 September 1998.
    • (1998) European Society of Biomaterials Meeting
    • Denayer, I.1    Van Der Perre, G.2
  • 21
    • 0026070354 scopus 로고
    • A 3-dimensional nonlinear finite-element study of the effect of cement-prosthesis debonding in cemented femoral total hip components
    • Harrigan, T. P., and Harris, W. H. A 3-dimensional nonlinear finite-element study of the effect of cement-prosthesis debonding in cemented femoral total hip components. J. Biomechanics, 1991, 24(11), 1047-1058.
    • (1991) J. Biomechanics , vol.24 , Issue.11 , pp. 1047-1058
    • Harrigan, T.P.1    Harris, W.H.2
  • 22
    • 0035662772 scopus 로고    scopus 로고
    • Evaluation of cement stresses in finite element analyses of cemented orthopaedic implants
    • Lennon, A. B., and Prendergast, P. J. Evaluation of cement stresses in finite element analyses of cemented orthopaedic implants. Trans. ASME, J. Biomech. Engng, 2001, 123(6), 623-628.
    • (2001) Trans. ASME, J. Biomech. Engng , vol.123 , Issue.6 , pp. 623-628
    • Lennon, A.B.1    Prendergast, P.J.2
  • 23
    • 0030561029 scopus 로고    scopus 로고
    • Subsidence of THA stems due to acrylic cement creep is extremely sensitive to interface friction
    • Verdonschot, N., and Huiskes, R. Subsidence of THA stems due to acrylic cement creep is extremely sensitive to interface friction. J. Biomechanics, 1996, 29(12), 1569-1575.
    • (1996) J. Biomechanics , vol.29 , Issue.12 , pp. 1569-1575
    • Verdonschot, N.1    Huiskes, R.2
  • 24
    • 0031052909 scopus 로고    scopus 로고
    • Cement debonding process of total hip arthroplasty stems
    • Verdonschot, N., and Huiskes, R. Cement debonding process of total hip arthroplasty stems. Clin. Orthop. Related Res., 1997, 336, 297-307.
    • (1997) Clin. Orthop. Related Res. , vol.336 , pp. 297-307
    • Verdonschot, N.1    Huiskes, R.2
  • 26
    • 0028214666 scopus 로고
    • The cement mantle in total hiparthroplasty - Analysis of long-term radiographic results
    • Ebramzadeh, E., Sarmiento, A., Mckellop, H. A., Llinas, A., and Gogan, W. The cement mantle in total hiparthroplasty - analysis of long-term radiographic results. J. Bone Jt Surg. - Am. Vol., 1994, 76A(1), 77-87.
    • (1994) J. Bone Jt Surg. - Am. , vol.76 A , Issue.1 , pp. 77-87
    • Ebramzadeh, E.1    Sarmiento, A.2    Mckellop, H.A.3    Llinas, A.4    Gogan, W.5
  • 28
    • 0016773856 scopus 로고
    • A radiological study of fractures of acrylic cement in relation to the stem of a femoral head prosthesis
    • Weber, F. A., and Charnley, J. A radiological study of fractures of acrylic cement in relation to the stem of a femoral head prosthesis. J. Bone Jt Surg., 1975, 57B, 297.
    • (1975) J. Bone Jt Surg. , vol.57 B , pp. 297
    • Weber, F.A.1    Charnley, J.2
  • 29
    • 0030175862 scopus 로고    scopus 로고
    • An experimental study of damage accumulation in cemented hip prostheses
    • McCormack, B. A. O., Prendergast, P. J., and Gallagher, D. G. An experimental study of damage accumulation in cemented hip prostheses. Clin. Biomechanics, 1996, 11(4), 214-219.
    • (1996) Clin. Biomechanics , vol.11 , Issue.4 , pp. 214-219
    • McCormack, B.A.O.1    Prendergast, P.J.2    Gallagher, D.G.3
  • 30
    • 0032164760 scopus 로고    scopus 로고
    • A statistical analysis of microcrack accumulation in PMMA under fatigue loading: Applications to orthopaedic implant fixation
    • McCormack, B. A. O., Walsh, C. D., Wilson, S. P., and Prendergast, P. I. A statistical analysis of microcrack accumulation in PMMA under fatigue loading: applications to orthopaedic implant fixation. Int. J. Fatigue, 1998, 20(8), 581-593.
    • (1998) Int. J. Fatigue , vol.20 , Issue.8 , pp. 581-593
    • McCormack, B.A.O.1    Walsh, C.D.2    Wilson, S.P.3    Prendergast, P.I.4
  • 31
    • 0037086742 scopus 로고    scopus 로고
    • The relationship between stress, porosity and nonlinear damage accumulation in acrylic bone cement
    • Murphy, B. P., and Prendergast, P. J. The relationship between stress, porosity and nonlinear damage accumulation in acrylic bone cement. J. Biomed. Mater. Res., 2002, 59(4), 646-654.
    • (2002) J. Biomed. Mater. Res. , vol.59 , Issue.4 , pp. 646-654
    • Murphy, B.P.1    Prendergast, P.J.2
  • 32
    • 0028501857 scopus 로고
    • Creep-behavior of hand-mixed Simplex-P bone-cement under cyclic tensile loading
    • Verdonschot, N., and Huiskes, R. Creep-behavior of hand-mixed Simplex-P bone-cement under cyclic tensile loading. J. Appl. Biomater., 1994, 5(3), 235-243.
    • (1994) J. Appl. Biomater. , vol.5 , Issue.3 , pp. 235-243
    • Verdonschot, N.1    Huiskes, R.2
  • 33
    • 0036208443 scopus 로고    scopus 로고
    • Finite element and experimental models of cemented hip joint reconstructions can produce similar bone and cement strains in pre-clinical tests
    • Stolk, J., Verdonschot, N., Cristofolini, L., Toni, A., and Huiskes, R. Finite element and experimental models of cemented hip joint reconstructions can produce similar bone and cement strains in pre-clinical tests. J. Biomechanics, 2002, 35(4), 499-510.
    • (2002) J. Biomechanics , vol.35 , Issue.4 , pp. 499-510
    • Stolk, J.1    Verdonschot, N.2    Cristofolini, L.3    Toni, A.4    Huiskes, R.5
  • 34
    • 0031278698 scopus 로고    scopus 로고
    • Cement-mantle thickness affects cement strains in total hip replacement
    • Fisher, D. A., Tsang, A. C., Paydar, N., Milionis, S., and Turner, C. H. Cement-mantle thickness affects cement strains in total hip replacement. J. Biomechanics, 1997, 30(11-12), 1173-1177.
    • (1997) J. Biomechanics , vol.30 , Issue.11-12 , pp. 1173-1177
    • Fisher, D.A.1    Tsang, A.C.2    Paydar, N.3    Milionis, S.4    Turner, C.H.5
  • 35
    • 0031140306 scopus 로고    scopus 로고
    • In vitro measured strains in the loaded femur: Quantification of experimental error
    • Cristofolini, L., McNamara, B. P., Freddi, A., and Viceconti, M. In vitro measured strains in the loaded femur: quantification of experimental error. J. Strain Analysis, 1997, 32(3), 193-200.
    • (1997) J. Strain Analysis , vol.32 , Issue.3 , pp. 193-200
    • Cristofolini, L.1    McNamara, B.P.2    Freddi, A.3    Viceconti, M.4
  • 36
    • 0031043430 scopus 로고    scopus 로고
    • Factors affecting cement strains near the tip of a cemented femoral component
    • Estok, D. M., Orr, T. E., and Harris, W. H. Factors affecting cement strains near the tip of a cemented femoral component. J. Arthroplasty, 1997, 12(1), 40-48.
    • (1997) J. Arthroplasty , vol.12 , Issue.1 , pp. 40-48
    • Estok, D.M.1    Orr, T.E.2    Harris, W.H.3
  • 38
    • 0023367463 scopus 로고
    • The effect of surface preparation on metal/bone cement interfacial strength
    • Bundy, K. J., and Penn, R. W. The effect of surface preparation on metal/bone cement interfacial strength. J. Biomed. Mater. Res., 1987, 21, 773-805.
    • (1987) J. Biomed. Mater. Res. , vol.21 , pp. 773-805
    • Bundy, K.J.1    Penn, R.W.2
  • 39
    • 0019545612 scopus 로고
    • The quasistatic and fatigue performance of the implant/bone-cement interface
    • Raab, S., Ahmed, A. M., and Provan, J. W. The quasistatic and fatigue performance of the implant/bone-cement interface. J. Biomed. Mater. Res., 1981, 15, 159-182.
    • (1981) J. Biomed. Mater. Res. , vol.15 , pp. 159-182
    • Raab, S.1    Ahmed, A.M.2    Provan, J.W.3
  • 40
    • 0025794964 scopus 로고
    • Non invasive evaluation of the prosthetic hip joint using the acousto-ultrasonic technique
    • Vaidya, U. K., and Raju, P. K. Non invasive evaluation of the prosthetic hip joint using the acousto-ultrasonic technique. Am. Soc. Mech. Engs, Des. Engng Div. (Publication) DE, 1991, 38, 299-302.
    • (1991) Am. Soc. Mech. Engs, Des. Engng Div. (Publication) DE , vol.38 , pp. 299-302
    • Vaidya, U.K.1    Raju, P.K.2
  • 41
    • 0029039382 scopus 로고
    • In vitro evaluation of bonding of the cement-metal interface of a total hip femoral component using ultrasound
    • Davies, J. P., Tse, M. K., and Harris, W. H. In vitro evaluation of bonding of the cement-metal interface of a total hip femoral component using ultrasound. J. Orthop. Res., 1995, 13(3), 335-338.
    • (1995) J. Orthop. Res. , vol.13 , Issue.3 , pp. 335-338
    • Davies, J.P.1    Tse, M.K.2    Harris, W.H.3
  • 42
    • 0029833853 scopus 로고    scopus 로고
    • Monitoring the integrity of the cement-metal interface of total joint components in vitro using acoustic emission and ultrasound
    • Davies, J. P., Tse, M. K., and Harris, W. H. Monitoring the integrity of the cement-metal interface of total joint components in vitro using acoustic emission and ultrasound. J. Arthroplasty, 1996, 11(5), 594-601.
    • (1996) J. Arthroplasty , vol.11 , Issue.5 , pp. 594-601
    • Davies, J.P.1    Tse, M.K.2    Harris, W.H.3
  • 43
    • 0029414501 scopus 로고
    • Acoustic emission and non destructive evaluation of biomaterials and tissues
    • Kohn, D. H. Acoustic emission and non destructive evaluation of biomaterials and tissues. Crit. Rev. Biomed. Engng, 1995, 23(3-41), 221-306.
    • (1995) Crit. Rev. Biomed. Engng , vol.23 , Issue.3-41 , pp. 221-306
    • Kohn, D.H.1
  • 45
    • 0039096806 scopus 로고
    • Acoustic emission monitoring of fracture mechanisms in short fibre reinforced thermoplastics: Basic studies on model compounds
    • Montreal, Canada, 21-25 July (Society for the Plastics Industry)
    • Wolters, J. Acoustic emission monitoring of fracture mechanisms in short fibre reinforced thermoplastics: basic studies on model compounds. In 2nd International Symposium on Acoustic Emission from Reinforced Composites, Montreal, Canada, 21-25 July 1986 (Society for the Plastics Industry).
    • (1986) 2nd International Symposium on Acoustic Emission from Reinforced Composites
    • Wolters, J.1
  • 46
    • 0028420079 scopus 로고
    • Prediction of fatigue life of composite femoral prostheses using acoustic-emission technique
    • Sundaresan, M. J., Henneke, E. G., and Reifsnider, K. L. Prediction of fatigue life of composite femoral prostheses using acoustic-emission technique. J. Composites Technol. Res., 1994, 16(2), 127-131.
    • (1994) J. Composites Technol. Res. , vol.16 , Issue.2 , pp. 127-131
    • Sundaresan, M.J.1    Henneke, E.G.2    Reifsnider, K.L.3
  • 47
    • 0142240451 scopus 로고    scopus 로고
    • In vitro acoustic waves propagation in human and bovine cancellous bone
    • Cardoso, L., Teboul, F., Sedel, L., Oddou, C., and Meunier, A. In vitro acoustic waves propagation in human and bovine cancellous bone. J. Bone Min. Res., 2003, 18(10), 1803-1812.
    • (2003) J. Bone Min. Res. , vol.18 , Issue.10 , pp. 1803-1812
    • Cardoso, L.1    Teboul, F.2    Sedel, L.3    Oddou, C.4    Meunier, A.5
  • 49
    • 0142058352 scopus 로고    scopus 로고
    • Acoustic wave propagation in bovine cancellous bone: Application of the modified Biot-Attenborough model
    • Lee, K. I., Roh, H. S., and Yoon, S. W. Acoustic wave propagation in bovine cancellous bone: application of the modified Biot-Attenborough model. J. Acoust. Soc. Am., 2003, 114(4), 2284-2293.
    • (2003) J. Acoust. Soc. Am. , vol.114 , Issue.4 , pp. 2284-2293
    • Lee, K.I.1    Roh, H.S.2    Yoon, S.W.3
  • 51
    • 0038263109 scopus 로고    scopus 로고
    • Multilayer analysis: Quantitative scanning acoustic microscopy for tissue characterization at a microscopic scale
    • Raum, K., Jenderka, K. V., Klemenz, A., and Brandt, J. Multilayer analysis: quantitative scanning acoustic microscopy for tissue characterization at a microscopic scale. IEEE Trans. Ultrasonics Ferroelectrics and Frequency Control, 2003, 50(5), 507-516.
    • (2003) IEEE Trans. Ultrasonics Ferroelectrics and Frequency Control , vol.50 , Issue.5 , pp. 507-516
    • Raum, K.1    Jenderka, K.V.2    Klemenz, A.3    Brandt, J.4
  • 52
    • 0034914752 scopus 로고    scopus 로고
    • Prediction of mechanical properties of healing fractures using acoustic emission
    • Watanabe, Y., Takai, S., Arai, Y., Yoshino, N., and Hirasawa, Y. Prediction of mechanical properties of healing fractures using acoustic emission. J. Orthop. Res., 2001, 19(4), 548-553.
    • (2001) J. Orthop. Res. , vol.19 , Issue.4 , pp. 548-553
    • Watanabe, Y.1    Takai, S.2    Arai, Y.3    Yoshino, N.4    Hirasawa, Y.5
  • 53
    • 13644280800 scopus 로고    scopus 로고
    • Performance of a confocal acoustic mapping in characterization of trabecular bone quality in human calcaneus
    • Xia, Y., Lin, W., Mittra, E., Demes, B., Gruber, B., Rubin, C., and Qin, Y. Performance of a confocal acoustic mapping in characterization of trabecular bone quality in human calcaneus. J. Bone Min. Res., 2003, 18, S209.
    • (2003) J. Bone Min. Res. , vol.18
    • Xia, Y.1    Lin, W.2    Mittra, E.3    Demes, B.4    Gruber, B.5    Rubin, C.6    Qin, Y.7
  • 54
    • 0035544731 scopus 로고    scopus 로고
    • Scanning acoustic microscopy study of human cortical and trabecular bone
    • Bumrerraj, S., and Katz, J. L. Scanning acoustic microscopy study of human cortical and trabecular bone. Ann. Biomed. Engng, 2001, 29(12), 1034-1042.
    • (2001) Ann. Biomed. Engng , vol.29 , Issue.12 , pp. 1034-1042
    • Bumrerraj, S.1    Katz, J.L.2
  • 55
    • 0035544732 scopus 로고    scopus 로고
    • Quantitative measurements of the mechanical properties of human bone tissues by scanning acoustic microscopy
    • Eckardt, I., and Hein, H. J. Quantitative measurements of the mechanical properties of human bone tissues by scanning acoustic microscopy. Ann. Biomed. Engng, 2001, 29(12), 1043-1047.
    • (2001) Ann. Biomed. Engng , vol.29 , Issue.12 , pp. 1043-1047
    • Eckardt, I.1    Hein, H.J.2
  • 56
    • 13644277893 scopus 로고    scopus 로고
    • Measurement of elastic modulus of individual trabeculae and microstructure of trabecular bone using scanning acoustic microscopy
    • Zhang, N., and Grimm, M. J. Measurement of elastic modulus of individual trabeculae and microstructure of trabecular bone using scanning acoustic microscopy. J. Bone Min. Res., 2000, 15, M029.
    • (2000) J. Bone Min. Res. , vol.15
    • Zhang, N.1    Grimm, M.J.2
  • 57
    • 0032127878 scopus 로고    scopus 로고
    • Acoustic emission analysis as a diagnostic tool for the examination of human bones
    • Orth, J., Schwalbe, H. J., Dorner, H. P., Fink, J., Brehmer, U., and Franke, R. P. Acoustic emission analysis as a diagnostic tool for the examination of human bones. Biomedizinische Technik, 1998, 43(7-8), 194-201.
    • (1998) Biomedizinische Technik , vol.43 , Issue.7-8 , pp. 194-201
    • Orth, J.1    Schwalbe, H.J.2    Dorner, H.P.3    Fink, J.4    Brehmer, U.5    Franke, R.P.6
  • 58
    • 0032611252 scopus 로고    scopus 로고
    • Non-destructive and non-invasive observation of friction and wear of human joints and of fracture initiation by acoustic emission
    • Schwalbe, H. J., Bamfaste, G., and Franke, R. P. Non-destructive and non-invasive observation of friction and wear of human joints and of fracture initiation by acoustic emission. Proc. Instn Mech. Engrs, Part H: J. Engineering in Medicine, 1999, 213(H1), 41-48.
    • (1999) Proc. Instn Mech. Engrs, Part H: J. Engineering in Medicine , vol.213 , Issue.H1 , pp. 41-48
    • Schwalbe, H.J.1    Bamfaste, G.2    Franke, R.P.3
  • 59
    • 0033363346 scopus 로고    scopus 로고
    • Use of acoustic emission to characterize focal and diffuse microdamage in bone
    • American Society for Testing and Materials, West Conshohocken, Pennsylvania
    • Rajachar, R. M., Chow, D. L., Curtis, C. E., Weissman, N. A., and Kohn, D. H. Use of acoustic emission to characterize focal and diffuse microdamage in bone. In Acoustic Emissions: Standards and Technology Update, 1999, pp. 3-19 (American Society for Testing and Materials, West Conshohocken, Pennsylvania).
    • (1999) Acoustic Emissions: Standards and Technology Update , pp. 3-19
    • Rajachar, R.M.1    Chow, D.L.2    Curtis, C.E.3    Weissman, N.A.4    Kohn, D.H.5
  • 60
    • 0036171714 scopus 로고    scopus 로고
    • Residual stress due to curing can initiate damage in porous bone cement: Experimental and theoretical evidence
    • Lennon, A. B., and Prendergast, P. J. Residual stress due to curing can initiate damage in porous bone cement: experimental and theoretical evidence. J. Biomechanics, 2002, 35(3), 311-321.
    • (2002) J. Biomechanics , vol.35 , Issue.3 , pp. 311-321
    • Lennon, A.B.1    Prendergast, P.J.2
  • 61
    • 0038078475 scopus 로고    scopus 로고
    • Shrinkage stresses in bone cement
    • Orr, J. F., Dunne, N. J., and Quinn, J. C. Shrinkage stresses in bone cement. Biomaterials, 2003, 24(17), 2933-2940.
    • (2003) Biomaterials , vol.24 , Issue.17 , pp. 2933-2940
    • Orr, J.F.1    Dunne, N.J.2    Quinn, J.C.3
  • 62
    • 0028434277 scopus 로고
    • Removal of bone-cement from the femoral canal using an acoustic emission-controlled milling device
    • Schmidt, J., and Nordmann, K. Removal of bone-cement from the femoral canal using an acoustic emission-controlled milling device. Med. Biolog. Engng Computing, 1994, 32(3), 258-260.
    • (1994) Med. Biolog. Engng Computing , vol.32 , Issue.3 , pp. 258-260
    • Schmidt, J.1    Nordmann, K.2
  • 63
    • 0036980593 scopus 로고    scopus 로고
    • Monitoring the setting of calcium-based bone cements using pulse-echo ultrasound
    • Nilsson, M., Carlson, J., Fernandez, E., and Planell, J. A. Monitoring the setting of calcium-based bone cements using pulse-echo ultrasound. J. Mater. Sci. - Mater. Medicine, 2002, 13(12), 1135-1141.
    • (2002) J. Mater. Sci. - Mater. Medicine , vol.13 , Issue.12 , pp. 1135-1141
    • Nilsson, M.1    Carlson, J.2    Fernandez, E.3    Planell, J.A.4
  • 64
    • 0035902899 scopus 로고    scopus 로고
    • Material fatigue behavior characterization using the wavelet-based AE technique - A case study of acrylic bone cement
    • Ng, E. T., and Qi, G. Material fatigue behavior characterization using the wavelet-based AE technique - a case study of acrylic bone cement. Engng Fracture Mechanics, 2001, 68(13), 1477-1492.
    • (2001) Engng Fracture Mechanics , vol.68 , Issue.13 , pp. 1477-1492
    • Ng, E.T.1    Qi, G.2
  • 65
    • 0034255850 scopus 로고    scopus 로고
    • Attenuation of acoustic emission body waves in acrylic bone cement and synthetic bone using wavelet time-scale analysis
    • Qi, G. Attenuation of acoustic emission body waves in acrylic bone cement and synthetic bone using wavelet time-scale analysis. J. Biomed. Mater. Res., 2000, 52(1), 148-156.
    • (2000) J. Biomed. Mater. Res. , vol.52 , Issue.1 , pp. 148-156
    • Qi, G.1
  • 66
    • 0034333642 scopus 로고    scopus 로고
    • 3-D AE visualization of bone-cement fatigue locations
    • Qi, G., Pujol, J., and Fan, Z. F. 3-D AE visualization of bone-cement fatigue locations. J. Biomed. Mater. Res., 2000, 52(2), 256-260.
    • (2000) J. Biomed. Mater. Res. , vol.52 , Issue.2 , pp. 256-260
    • Qi, G.1    Pujol, J.2    Fan, Z.F.3
  • 67
    • 0036133085 scopus 로고    scopus 로고
    • Comments on acoustic emission visualization of bone cement fatigue locations
    • Akkus, O. Comments on acoustic emission visualization of bone cement fatigue locations. J. Biomed. Mater. Res., 2002, 59(2), 398-399.
    • (2002) J. Biomed. Mater. Res. , vol.59 , Issue.2 , pp. 398-399
    • Akkus, O.1
  • 68
    • 85068814538 scopus 로고    scopus 로고
    • Comments on acoustic emission visualization of bone cement fatigue locations - Reply
    • Pujol, J., and Qi, G. Comments on acoustic emission visualization of bone cement fatigue locations - reply. J. Biomed. Mater. Res., 2002, 59(2), 399-401.
    • (2002) J. Biomed. Mater. Res. , vol.59 , Issue.2 , pp. 399-401
    • Pujol, J.1    Qi, G.2
  • 69
    • 0242541503 scopus 로고
    • Study of acoustic emission associated with fatigue damage to aluminium alloys
    • Presented at the Winter Annual Meeting of the American Society of Mechanical Engineers, New Orleans, Louisiana, sponsored by the Production Engineering Division, ASME, 9-14 December (Ed. D. A. Donfield), 1984 (American Society of Mechanical Engineers, New York)
    • Cherfaoui, M., Chretien, J. F., Spieldener, J. P., and Rodget, J. Study of acoustic emission associated with fatigue damage to aluminium alloys. Presented at the Winter Annual Meeting of the American Society of Mechanical Engineers, New Orleans, Louisiana, sponsored by the Production Engineering Division, ASME, 9-14 December 1984; in Acoustic Emissions Monitoring and Analysis in Manufacturing (Ed. D. A. Donfield), 1984 (American Society of Mechanical Engineers, New York).
    • (1984) Acoustic Emissions Monitoring and Analysis in Manufacturing
    • Cherfaoui, M.1    Chretien, J.F.2    Spieldener, J.P.3    Rodget, J.4
  • 70
    • 0021577628 scopus 로고
    • Characterization of the fracture process in PMMA by acoustic emission analysis
    • Presented at the Winter Annual Meeting of the American Society of Mechanical Engineers, New Orleans, Louisiana, sponsored by the Production Engineering Division, ASME, 9-14 December 1984; (Ed. D. A. Donfield), (American Society of Mechanical Engineers, New York)
    • Grabec, I. Characterization of the fracture process in PMMA by acoustic emission analysis. Presented at the Winter Annual Meeting of the American Society of Mechanical Engineers, New Orleans, Louisiana, sponsored by the Production Engineering Division, ASME, 9-14 December 1984; in Acoustic Emissions Monitoring and Analysis in Manufacturing (Ed. D. A. Donfield), 1984 (American Society of Mechanical Engineers, New York).
    • (1984) Acoustic Emissions Monitoring and Analysis in Manufacturing
    • Grabec, I.1
  • 71
    • 0035239216 scopus 로고    scopus 로고
    • Confocal laser scanning microscopy and scanning electron microscopy of tissue Ti-implant interfaces
    • Baschong, W., Suetterlin, R., Hefti, A., and Schiel, H. Confocal laser scanning microscopy and scanning electron microscopy of tissue Ti-implant interfaces. Micron, 2001, 32(1), 33-11.
    • (2001) Micron , vol.32 , Issue.1 , pp. 33-111
    • Baschong, W.1    Suetterlin, R.2    Hefti, A.3    Schiel, H.4
  • 72
    • 0033167967 scopus 로고    scopus 로고
    • Reliability theory for load bearing biomedical implants
    • Browne, M., Langley, R. S., and Gregson, P. J. Reliability theory for load bearing biomedical implants. Biomaterials, 1999, 20(14), 1285-1292.
    • (1999) Biomaterials , vol.20 , Issue.14 , pp. 1285-1292
    • Browne, M.1    Langley, R.S.2    Gregson, P.J.3
  • 73
    • 0031699750 scopus 로고    scopus 로고
    • Ultrasonic evaluation of ultra-high molecular weight polyethylene used in medical prostheses
    • Ong, C. S., and Saffari, N. Ultrasonic evaluation of ultra-high molecular weight polyethylene used in medical prostheses. Proc. Instn Mech. Engrs, Part H: J. Engineering in Medicine, 1998, 212(H1), 65-69.
    • (1998) Proc. Instn Mech. Engrs, Part H: J. Engineering in Medicine , vol.212 , Issue.H1 , pp. 65-69
    • Ong, C.S.1    Saffari, N.2
  • 75
    • 0026864135 scopus 로고
    • A fractographic investigation of PMMA bone cement focusing on the relationship between porosity reduction and increased fatigue life
    • James, S. P., Jasty, M., Davies, J., Piehler, H., and Harris, W. H. A fractographic investigation of PMMA bone cement focusing on the relationship between porosity reduction and increased fatigue life. J. Biomed. Mater. Res., 1992, 26(5), 651-662.
    • (1992) J. Biomed. Mater. Res. , vol.26 , Issue.5 , pp. 651-662
    • James, S.P.1    Jasty, M.2    Davies, J.3    Piehler, H.4    Harris, W.H.5
  • 76
    • 0036135545 scopus 로고    scopus 로고
    • Effects of humidity on environmental stress cracking behavior in poly(methyl methacrylate)
    • Ishiyama, C., Sakuma, T., Shimojo, M., and Higo, Y. Effects of humidity on environmental stress cracking behavior in poly(methyl methacrylate). J. Polym. Sci. Part B- Polym. Physics, 2002, 40(1), 1-9.
    • (2002) J. Polym. Sci. Part B- Polym. Physics , vol.40 , Issue.1 , pp. 1-9
    • Ishiyama, C.1    Sakuma, T.2    Shimojo, M.3    Higo, Y.4
  • 77
    • 13644283174 scopus 로고    scopus 로고
    • The effect of creep and load level on the damage accumulation within the cement mantle of the cemented implanted femur
    • Sonesta Beach Resort in Key Biscayne, Florida
    • Jeffers, J. R. T., and Taylor, M. The effect of creep and load level on the damage accumulation within the cement mantle of the cemented implanted femur. In Summer Bioengineering Conference, Sonesta Beach Resort in Key Biscayne, Florida, 2003.
    • (2003) Summer Bioengineering Conference
    • Jeffers, J.R.T.1    Taylor, M.2
  • 78
    • 0020097103 scopus 로고
    • Transient and residual-stresses and displacements in self-curing bone-cement. 1. Characterization of relevant volumetric behavior of bone-cement
    • Ahmed, A. M., Pak, W., Burke, D. L., and Miller, J. Transient and residual-stresses and displacements in self-curing bone-cement. 1. Characterization of relevant volumetric behavior of bone-cement. Trans. ASME, J. Biomech. Engng, 1982, 104(1), 21-27.
    • (1982) Trans. ASME, J. Biomech. Engng , vol.104 , Issue.1 , pp. 21-27
    • Ahmed, A.M.1    Pak, W.2    Burke, D.L.3    Miller, J.4
  • 79
    • 0029361044 scopus 로고
    • Comparison of diametral shrinkage of centrifuged and uncentrifuged Simplex P(R) bone-cement
    • Davies, J. P., and Harris, W. H. Comparison of diametral shrinkage of centrifuged and uncentrifuged Simplex P(R) bone-cement. J. Appl. Biomater., 1995, 6(3), 209-211.
    • (1995) J. Appl. Biomater. , vol.6 , Issue.3 , pp. 209-211
    • Davies, J.P.1    Harris, W.H.2
  • 80
    • 0034255618 scopus 로고    scopus 로고
    • A theoretical and experimental analysis of polymerization shrinkage of bone cement: A potential major source of porosity
    • Gilbert, J. L., Hasenwinkel, J. M., Wixson, R. L., and Lautenschlager, E. P. A theoretical and experimental analysis of polymerization shrinkage of bone cement: a potential major source of porosity. J. Biomed. Mater. Res., 2000, 52(1), 210-218.
    • (2000) J. Biomed. Mater. Res. , vol.52 , Issue.1 , pp. 210-218
    • Gilbert, J.L.1    Hasenwinkel, J.M.2    Wixson, R.L.3    Lautenschlager, E.P.4
  • 81
    • 1642279056 scopus 로고    scopus 로고
    • Predictions of residual stresses in bone cement for joint arthroplasty
    • Calgary, Alberta, Canada, 4-9 August
    • Li, C., Wang, Y., Schmid, S., and Mason, J. Predictions of residual stresses in bone cement for joint arthroplasty. In IVth World Congress on Biomechanics, Calgary, Alberta, Canada, 4-9 August 2002.
    • (2002) IVth World Congress on Biomechanics
    • Li, C.1    Wang, Y.2    Schmid, S.3    Mason, J.4
  • 82
    • 0036000232 scopus 로고    scopus 로고
    • Residual stresses at the stem-cement interface of an idealized cemented hip stem
    • Nuno, N., and Avanzolini, G. Residual stresses at the stem-cement interface of an idealized cemented hip stem. J. Biomechanics, 2002, 35(6), 849-852.
    • (2002) J. Biomechanics , vol.35 , Issue.6 , pp. 849-852
    • Nuno, N.1    Avanzolini, G.2
  • 83
    • 1642402000 scopus 로고    scopus 로고
    • Quantitative measurement of the stresses induced during polymerisation of bone cement
    • in press
    • Roques, A., Browne, M., Taylor, A., New, A., and Baker, D. Quantitative measurement of the stresses induced during polymerisation of bone cement. Biomaterials, 2004 (in press).
    • (2004) Biomaterials
    • Roques, A.1    Browne, M.2    Taylor, A.3    New, A.4    Baker, D.5
  • 85
    • 1642332674 scopus 로고    scopus 로고
    • Shrinkage of vacuum mixed cement causes interfaces gaps and stress concentrations in cement mantles surrounding femoral stems
    • Calgary, Alberta, Canada, 4-9 August
    • Race, A., Miller, A., Ayers, D., and Mann, K. Shrinkage of vacuum mixed cement causes interfaces gaps and stress concentrations in cement mantles surrounding femoral stems. In IVth World Congress on Biomechanics, Calgary, Alberta, Canada, 4-9 August 2002.
    • (2002) IVth World Congress on Biomechanics
    • Race, A.1    Miller, A.2    Ayers, D.3    Mann, K.4
  • 86
    • 0242522398 scopus 로고    scopus 로고
    • Investigation of fatigue crack growth in acrylic bone cement using the acoustic emission technique
    • Roques, A., Browne, M., Thompson, J., Rowland, C., and Taylor, A. Investigation of fatigue crack growth in acrylic bone cement using the acoustic emission technique. Biomaterials, 2004, 25(5), 769-778.
    • (2004) Biomaterials , vol.25 , Issue.5 , pp. 769-778
    • Roques, A.1    Browne, M.2    Thompson, J.3    Rowland, C.4    Taylor, A.5
  • 87
    • 0032143082 scopus 로고    scopus 로고
    • Composite technology in load-bearing orthopaedic implants
    • Evans, S. L., and Gregson, P. J. Composite technology in load-bearing orthopaedic implants. Biomaterials, 1998, 19(15), 1329-1342.
    • (1998) Biomaterials , vol.19 , Issue.15 , pp. 1329-1342
    • Evans, S.L.1    Gregson, P.J.2
  • 89
    • 0002893749 scopus 로고
    • A discussion of the basic understanding of the felicity effect in fiber composites
    • Hamstad, M. A. A discussion of the basic understanding of the felicity effect in fiber composites. J. Acoust. Emissions, 1986, 5(2), 95-102.
    • (1986) J. Acoust. Emissions , vol.5 , Issue.2 , pp. 95-102
    • Hamstad, M.A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.