메뉴 건너뛰기




Volumn 204, Issue 1-2, 2004, Pages 109-124

The precise and accurate determination of thallium isotope compositions and concentrations for water samples by MC-ICPMS

Author keywords

Accuracy; ICPMS; Precision; Stable isotopes; Thallium

Indexed keywords

ACCURACY ASSESSMENT; ANALYTICAL METHOD; INDUCTIVELY COUPLED PLASMA METHOD; ISOTOPIC COMPOSITION; MASS SPECTROMETRY; PRECISION; THALLIUM; WATER CHEMISTRY;

EID: 1342320606     PISSN: 00092541     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.chemgeo.2003.11.006     Document Type: Article
Times cited : (114)

References (29)
  • 1
    • 0035298642 scopus 로고    scopus 로고
    • Precise determination of mass-dependent variations in the isotopic composition of molybdenum using MC-ICPMS
    • Anbar A.D. Knab K.A. Barling J. Precise determination of mass-dependent variations in the isotopic composition of molybdenum using MC-ICPMS Anal. Chem. 73 7 2001 1425-1431
    • (2001) Anal. Chem. , vol.73 , Issue.7 , pp. 1425-1431
    • Anbar, A.D.1    Knab, K.A.2    Barling, J.3
  • 2
    • 0347758344 scopus 로고    scopus 로고
    • Fe isotope variations in natural materials measured using high mass resolution MC-ICP-MS
    • Arnold G.L. Weyer S. Anbar A.D. Fe isotope variations in natural materials measured using high mass resolution MC-ICP-MS Anal. Chem. 2004
    • (2004) Anal. Chem.
    • Arnold, G.L.1    Weyer, S.2    Anbar, A.D.3
  • 3
    • 1442283665 scopus 로고    scopus 로고
    • 204Pb double spike and thallium to correct for mass bias with a double focusing MC-ICP-MS
    • 204Pb double spike and thallium to correct for mass bias with a double focusing MC-ICP-MS Chem. Geol. 2004
    • (2004) Chem. Geol.
    • Baker, J.1    Waight, T.2    Meycen, C.3
  • 5
    • 0346307794 scopus 로고    scopus 로고
    • A new variable dispersion double-focusing plasma mass spectrometer with performance illustrated for Pb isotopes
    • Belshaw N.S. Freedman P.A. O'Nions R.K. Frank M. Guo Y. A new variable dispersion double-focusing plasma mass spectrometer with performance illustrated for Pb isotopes Int. J. Mass Spectrom. 181 1998 51-58
    • (1998) Int. J. Mass Spectrom. , vol.181 , pp. 51-58
    • Belshaw, N.S.1    Freedman, P.A.2    O'Nions, R.K.3    Frank, M.4    Guo, Y.5
  • 7
    • 0035197611 scopus 로고    scopus 로고
    • Thallium contamination of water in Canada
    • Cheam V. Thallium contamination of water in Canada Water Qual. Res. J. Can. 36 4 2001 851-877
    • (2001) Water Qual. Res. J. Can. , vol.36 , Issue.4 , pp. 851-877
    • Cheam, V.1
  • 8
    • 0037200286 scopus 로고    scopus 로고
    • Applications of accurate, high-precision Pb isotope ratio measurement by multi-collector ICP-MS
    • Collerson K.D. Kamber B.S. Schoenberg R. Applications of accurate, high-precision Pb isotope ratio measurement by multi-collector ICP-MS Chem. Geol. 188 1-2 2002 65-83
    • (2002) Chem. Geol. , vol.188 , Issue.1-2 , pp. 65-83
    • Collerson, K.D.1    Kamber, B.S.2    Schoenberg, R.3
  • 9
    • 0037586874 scopus 로고    scopus 로고
    • Measurement of silicon stable isotope natural abundances via multicollector inductively coupled plasma mass spectrometry (MC-ICP-MS)
    • De la Rocha C.L. Measurement of silicon stable isotope natural abundances via multicollector inductively coupled plasma mass spectrometry (MC-ICP-MS) Geochem. Geophys. Geosyst. 3 2002
    • (2002) Geochem. Geophys. Geosyst. , vol.3
    • De la Rocha, C.L.1
  • 10
    • 0001766265 scopus 로고
    • Measurement of iron isotopes (Fe-54, Fe-56, Fe-57, and Fe-58) in submicrogram quantities of iron
    • Dixon P.R., et-al. Measurement of iron isotopes (Fe-54, Fe-56, Fe-57, and Fe-58) in submicrogram quantities of iron Anal. Chem. 65 15 1993 2125-2130
    • (1993) Anal. Chem. , vol.65 , Issue.15 , pp. 2125-2130
    • Dixon, P.R.1
  • 11
    • 0018917311 scopus 로고
    • Absolute isotopic abundance and the atomic weight of a reference sample of thallium
    • Dunstan L.P. Gramlich J.W. Barnes I.L. Purdy W.C. Absolute isotopic abundance and the atomic weight of a reference sample of thallium J. Res. Natl. Bur. Stand. 85 1 1980 1-10
    • (1980) J. Res. Natl. Bur. Stand. , vol.85 , Issue.1 , pp. 1-10
    • Dunstan, L.P.1    Gramlich, J.W.2    Barnes, I.L.3    Purdy, W.C.4
  • 12
    • 0022221893 scopus 로고
    • Thallium concentrations in seawater
    • Flegal A.R. Patterson C.C. Thallium concentrations in seawater Mar. Chem. 15 1985 327-331
    • (1985) Mar. Chem. , vol.15 , pp. 327-331
    • Flegal, A.R.1    Patterson, C.C.2
  • 13
    • 85128067239 scopus 로고    scopus 로고
    • Cobalt-rich ferromanganese crusts in the Pacific
    • D.S. Cronan (Ed.), Boca Raton: CRC Press
    • Hein J.R., et-al. Cobalt-rich ferromanganese crusts in the Pacific Cronan D.S. Handbook of Marine Mineral Deposits 2000 239-280 CRC Press Boca Raton
    • (2000) Handbook of Marine Mineral Deposits , pp. 239-280
    • Hein, J.R.1
  • 15
    • 0033214869 scopus 로고    scopus 로고
    • Thallium speciation in the Great Lakes
    • Lin T.-S. Nriagu J. Thallium speciation in the Great Lakes Environ. Sci. Technol. 33 1999 3394-3397
    • (1999) Environ. Sci. Technol. , vol.33 , pp. 3394-3397
    • Lin, T.-S.1    Nriagu, J.2
  • 16
    • 0002030318 scopus 로고
    • Determination of lead isotope ratios by inductively coupled plasma-mass spectrometry (ICP-MS)
    • Longerich H.P. Fryer B.J. Strong D.F. Determination of lead isotope ratios by inductively coupled plasma-mass spectrometry (ICP-MS) Spectrochim. Acta, Part B: Atom. Spectrosc. 42 1-2 1987 39-48
    • (1987) Spectrochim. Acta :Atom. Spectrosc. , vol.42 , Issue.1-2 PART B , pp. 39-48
    • Longerich, H.P.1    Fryer, B.J.2    Strong, D.F.3
  • 17
    • 0038681088 scopus 로고    scopus 로고
    • Precise analysis of copper and zinc isotopic compositions by plasma-source mass spectrometry
    • Maréchal C.N. Télouk P. Albarède F. Precise analysis of copper and zinc isotopic compositions by plasma-source mass spectrometry Chem. Geol. 156 1-4 1999 251-273
    • (1999) Chem. Geol. , vol.156 , Issue.1-4 , pp. 251-273
    • Maréchal, C.N.1    Télouk, P.2    Albarède, F.3
  • 18
    • 0009064587 scopus 로고
    • The determination of thallium in silicate rocks, marine sediments and sea water
    • Matthews A.D. Riley J.P. The determination of thallium in silicate rocks, marine sediments and sea water Anal. Chim. Acta 48 1969 25-34
    • (1969) Anal. Chim. Acta , vol.48 , pp. 25-34
    • Matthews, A.D.1    Riley, J.P.2
  • 19
    • 0006798414 scopus 로고
    • The occurrence of thallium in sea water and marine sediments
    • Matthews A.D. Riley J.P. The occurrence of thallium in sea water and marine sediments Chem. Geol. 149 1970 149-152
    • (1970) Chem. Geol. , vol.149 , pp. 149-152
    • Matthews, A.D.1    Riley, J.P.2
  • 20
    • 0347988308 scopus 로고    scopus 로고
    • The precise measurement of Tl isotopic compositions by MC-ICPMS: Application to the analysis of geological materials and meteorites
    • Rehkämper M. Halliday A.N. The precise measurement of Tl isotopic compositions by MC-ICPMS: Application to the analysis of geological materials and meteorites Geochim. Cosmochim. Acta 63 6 1999 935-944
    • (1999) Geochim. Cosmochim. Acta , vol.63 , Issue.6 , pp. 935-944
    • Rehkämper, M.1    Halliday, A.N.2
  • 21
    • 0042869238 scopus 로고    scopus 로고
    • Investigation of matrix effects for Pb isotope ratio measurements by multiple collector ICP-MS: Verification and application of optimized analytical protocols
    • Rehkämper M. Mezger K. Investigation of matrix effects for Pb isotope ratio measurements by multiple collector ICP-MS: Verification and application of optimized analytical protocols J. Anal. At. Spectrom. 15 11 2000 1451-1460
    • (2000) J. Anal. At. Spectrom. , vol.15 , Issue.11 , pp. 1451-1460
    • Rehkämper, M.1    Mezger, K.2
  • 22
    • 5344263263 scopus 로고    scopus 로고
    • Multiple collector ICP-MS: Introduction to instrumentation, measurement techniques and analytical capabilities
    • Rehkämper M. Schönbächler M. Stirling C.H. Multiple collector ICP-MS: Introduction to instrumentation, measurement techniques and analytical capabilities Geostand. Newsl. 25 1 2001 23-40
    • (2001) Geostand. Newsl. , vol.25 , Issue.1 , pp. 23-40
    • Rehkämper, M.1    Schönbächler, M.2    Stirling, C.H.3
  • 23
    • 0036257111 scopus 로고    scopus 로고
    • Thallium isotope variations in seawater and hydrogenetic, diagenetic, and hydrothermal ferromanganese deposits
    • Rehkämper M., et-al. Thallium isotope variations in seawater and hydrogenetic, diagenetic, and hydrothermal ferromanganese deposits Earth Planet. Sci. Lett. 197 1-2 2002 65-81
    • (2002) Earth Planet. Sci. Lett. , vol.197 , Issue.1-2 , pp. 65-81
    • Rehkämper, M.1
  • 25
    • 0034740668 scopus 로고    scopus 로고
    • Inappropriate tail corrections can cause large inaccuracy in isotope ratio determination by MC-ICP-MS
    • Thirlwall M. Inappropriate tail corrections can cause large inaccuracy in isotope ratio determination by MC-ICP-MS J. Anal. At. Spectrom. 16 10 2001 1121-1125
    • (2001) J. Anal. At. Spectrom. , vol.16 , Issue.10 , pp. 1121-1125
    • Thirlwall, M.1
  • 26
    • 0036117583 scopus 로고    scopus 로고
    • 204Pb double spike demonstrates up to 400 ppm/amu systematic errors in Tl-normalization
    • 204Pb double spike demonstrates up to 400 ppm/amu systematic errors in Tl-normalization Chem. Geol. 184 3-4 2002 255-279
    • (2002) Chem. Geol. , vol.184 , Issue.3-4 , pp. 255-279
    • Thirlwall, M.F.1
  • 27
    • 0343776942 scopus 로고    scopus 로고
    • High-precision analysis of Pb isotope ratios by multi-collector ICP-MS
    • White W.M. Albarède F. Télouk P. High-precision analysis of Pb isotope ratios by multi-collector ICP-MS Chem. Geol. 167 3-4 2000 257-270
    • (2000) Chem. Geol. , vol.167 , Issue.3-4 , pp. 257-270
    • White, W.M.1    Albarède, F.2    Télouk, P.3
  • 28
    • 0345375571 scopus 로고    scopus 로고
    • Stable isotope compositions of cadmium in geological materials and meteorites determined by multiple collector-ICPMS
    • Wombacher F. Rehkämper M. Mezger K. Münker C. Stable isotope compositions of cadmium in geological materials and meteorites determined by multiple collector-ICPMS Geochim. Cosmochim. Acta 67 23 2003 4639-4654
    • (2003) Geochim. Cosmochim. Acta , vol.67 , Issue.23 , pp. 4639-4654
    • Wombacher, F.1    Rehkämper, M.2    Mezger, K.3    Münker, C.4
  • 29
    • 0036026510 scopus 로고    scopus 로고
    • A simple method for obtaining highly accurate Pb isotope data by MC-ICP-MS
    • Woodhead J. A simple method for obtaining highly accurate Pb isotope data by MC-ICP-MS J. Anal. At. Spectrom. 17 10 2002 1381-1385
    • (2002) J. Anal. At. Spectrom. , vol.17 , Issue.10 , pp. 1381-1385
    • Woodhead, J.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.