메뉴 건너뛰기




Volumn , Issue 1445, 2004, Pages 86-103

The wear of highly crosslinked UHMWPE in the presence of abrasive particles: Hip and knee simulator studies

Author keywords

Crosslinked polyethylene; Hip; Knee; Three body; UHMWPE; Wear

Indexed keywords

ALUMINA; BONE CEMENT; JOINT PROSTHESES; JOINTS (ANATOMY); MATERIALS TESTING; MOLECULAR ORIENTATION; SIMULATORS; WEAR OF MATERIALS; WEAR RESISTANCE;

EID: 1342291193     PISSN: 00660558     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1520/stp11924s     Document Type: Article
Times cited : (3)

References (21)
  • 1
    • 0029725748 scopus 로고    scopus 로고
    • Mechanistics and morphological origins of ultra-high molecular weight polyethylene wear debris in total joint replacement prostheses
    • Wang, A., Stark, C., Dumbleton, J., "Mechanistics and morphological origins of ultra-high molecular weight polyethylene wear debris in total joint replacement prostheses", Proceedings of the Institution of Mechanical Engineers, Vol. 210, 1996, pp. 141-155.
    • (1996) Proceedings of the Institution of Mechanical Engineers , vol.210 , pp. 141-155
    • Wang, A.1    Stark, C.2    Dumbleton, J.3
  • 5
    • 0025854645 scopus 로고
    • Cellular events in the mechanisms of prosthesis loosening
    • Pizzoferrato, A., Ciapetti, G., Stea, S., Toni, A., "Cellular Events in the Mechanisms of Prosthesis Loosening", Clinical Materials, Vol. 7, 1991, pp. 51-81.
    • (1991) Clinical Materials , vol.7 , pp. 51-81
    • Pizzoferrato, A.1    Ciapetti, G.2    Stea, S.3    Toni, A.4
  • 9
    • 0032795522 scopus 로고    scopus 로고
    • Efficacy of irrigation for removal of particulate debris after cemented total knee arthroplasty
    • Helmers, S., Sharkey, P.F., McGuigan, F.X., "Efficacy of irrigation for removal of particulate debris after cemented total knee arthroplasty", Journal of Arthroplasty, Vol. 14, 1999, pp. 549-552.
    • (1999) Journal of Arthroplasty , vol.14 , pp. 549-552
    • Helmers, S.1    Sharkey, P.F.2    McGuigan, F.X.3
  • 10
    • 0035482830 scopus 로고    scopus 로고
    • The effect of minimum load on the fluid uptake and wear of highly crosslinked UHMWPE total hip acetabular components
    • Yao, J.Q., Laurent, M.P., Gilbertson, L.N., Crowninshield, R.D., "The effect of minimum load on the fluid uptake and wear of highly crosslinked UHMWPE total hip acetabular components", Wear, Vol. 250, 2001, pp. 140-144.
    • (2001) Wear , vol.250 , pp. 140-144
    • Yao, J.Q.1    Laurent, M.P.2    Gilbertson, L.N.3    Crowninshield, R.D.4
  • 11
    • 0038383422 scopus 로고    scopus 로고
    • In-vivo contact kinematics of the knee joint: Advancing the point-cluster technique
    • Ph.D. Dissertation, University of Minnesota
    • Johnson, T.S., "In-Vivo Contact Kinematics of the Knee Joint: Advancing the Point-Cluster Technique", Ph.D. Dissertation, University of Minnesota, 1999.
    • (1999)
    • Johnson, T.S.1
  • 12
    • 0035482037 scopus 로고    scopus 로고
    • The effect of displacement control input parameters on tibiofemoral prosthetic knee wear
    • Johnson, T.S., Laurent, M.P., Yao, J.Q., Gilbertson, L.N., "The effect of displacement control input parameters on tibiofemoral prosthetic knee wear", Wear, Vol. 250, 2001, pp. 222-226.
    • (2001) Wear , vol.250 , pp. 222-226
    • Johnson, T.S.1    Laurent, M.P.2    Yao, J.Q.3    Gilbertson, L.N.4
  • 21
    • 0032079093 scopus 로고    scopus 로고
    • Analysis of the kinematics of different hip simulators used to study wear candidate materials for the articulation of total hip arthroplasties
    • Ramamurti, B.S., Estok, D.M., Jasty, M., Harris, W.H., "Analysis of the Kinematics of Different Hip Simulators Used to Study Wear Candidate Materials for the Articulation of Total Hip Arthroplasties", Journal of Orthopaedic Research, Vol. 16, 1998, pp. 365-369.
    • (1998) Journal of Orthopaedic Research , vol.16 , pp. 365-369
    • Ramamurti, B.S.1    Estok, D.M.2    Jasty, M.3    Harris, W.H.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.