메뉴 건너뛰기




Volumn 28, Issue SUPPL. 1, 2005, Pages

Evaluation of the atrial evoked response for capture detection with high-polarization leads

Author keywords

Atrial AutoCapture ; Automatic output regulation; Evoked response; Paced depolarization integral; Pacemaker; Polarization

Indexed keywords

AGED; CLINICAL ARTICLE; CONFERENCE PAPER; ELECTRIC CONDUCTIVITY; ELECTROCARDIOGRAM; ELECTROGRAPHY; EVOKED RESPONSE; FEMALE; HEART ATRIUM PACING; HEART BEAT; HEART ELECTROPHYSIOLOGY; HEART MUSCLE POTENTIAL; HEART RHYTHM; HUMAN; MALE; PACEMAKER; PACEMAKER ELECTRODE; POLARIZATION; SIGNAL TRANSDUCTION;

EID: 12844263590     PISSN: 01478389     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1540-8159.2005.00059.x     Document Type: Conference Paper
Times cited : (8)

References (18)
  • 1
    • 0033665388 scopus 로고    scopus 로고
    • Benefits in projected pacemaker longevity and in pacing related costs conferred by automatic threshold tracking
    • Boriani G, Biffi M, Branzi A, et al. Benefits in projected pacemaker longevity and in pacing related costs conferred by automatic threshold tracking. PACE 2000; 23:1783-1787.
    • (2000) PACE , vol.23 , pp. 1783-1787
    • Boriani, G.1    Biffi, M.2    Branzi, A.3
  • 2
    • 12844286523 scopus 로고    scopus 로고
    • Cumulative experience with AutoCapture controlled pacing in 47 children
    • Bauersfield U, Novak B. Cumulative experience with AutoCapture controlled pacing in 47 children. PACE 2000; 23:636.
    • (2000) PACE , vol.23 , pp. 636
    • Bauersfield, U.1    Novak, B.2
  • 3
    • 0035405529 scopus 로고    scopus 로고
    • A cardiac evoked response algorithm providing automatic threshold tracking for continuous capture verification: A single-center prospective study
    • Verma P, Sharma J, Khan I, et al. A cardiac evoked response algorithm providing automatic threshold tracking for continuous capture verification: A single-center prospective study. Indian Heart J 2001; 53:467-476.
    • (2001) Indian Heart J , vol.53 , pp. 467-476
    • Verma, P.1    Sharma, J.2    Khan, I.3
  • 4
    • 0034486355 scopus 로고    scopus 로고
    • Acute effects of a class IA antiarrhythmic drug on the ventricular evoked response amplitude in patients with cardiac pacemakers
    • Schuchert A, Meinertz T. Acute effects of a class IA antiarrhythmic drug on the ventricular evoked response amplitude in patients with cardiac pacemakers. Cardiology 2000; 94:103-105.
    • (2000) Cardiology , vol.94 , pp. 103-105
    • Schuchert, A.1    Meinertz, T.2
  • 5
    • 0001986490 scopus 로고
    • The electrode - Biointerface: Stimulation
    • SG Barold (Ed.): Mount kisco, NY, Futura Publishing Co.
    • Bornzin G, Stokes K. The electrode - Biointerface: Stimulation. In SG Barold (Ed.): Modern cardiac pacing. Mount kisco, NY, Futura Publishing Co., 1985, pp. 33-77.
    • (1985) Modern Cardiac Pacing , pp. 33-77
    • Bornzin, G.1    Stokes, K.2
  • 7
    • 3242673185 scopus 로고    scopus 로고
    • Automatic capture verification in pacemakers (Autocapture) - Utility and problems
    • Kam R. Automatic capture verification in pacemakers (Autocapture) - utility and problems. Indian Pacing Electrophysiol J 2004; 4:73-78.
    • (2004) Indian Pacing Electrophysiol J , vol.4 , pp. 73-78
    • Kam, R.1
  • 8
    • 0024235851 scopus 로고
    • Atrial capture detection with endocardial electrodes
    • Livingston A, Callaghan F, Byrd C, et al. Atrial capture detection with endocardial electrodes. PACE 1988; 11:1770-1776.
    • (1988) PACE , vol.11 , pp. 1770-1776
    • Livingston, A.1    Callaghan, F.2    Byrd, C.3
  • 9
    • 0025002167 scopus 로고
    • Alternate methods for the determination of atrial capture threshold utilizing the telemetered intracardiac electrogram
    • Feuer J, Florio J, Shandling A. Alternate methods for the determination of atrial capture threshold utilizing the telemetered intracardiac electrogram. PACE 1990; 13:1254-1260.
    • (1990) PACE , vol.13 , pp. 1254-1260
    • Feuer, J.1    Florio, J.2    Shandling, A.3
  • 10
    • 0346221717 scopus 로고    scopus 로고
    • Clinical validation of new pacing-sensing configurations for automatic atrial capture verification in pacemakers
    • abstract
    • Kay G, Butter C, Hartung W, et al. Clinical validation of new pacing-sensing configurations for automatic atrial capture verification in pacemakers. (abstract) PACE 2000; 23:576.
    • (2000) PACE , vol.23 , pp. 576
    • Kay, G.1    Butter, C.2    Hartung, W.3
  • 11
    • 0347482799 scopus 로고    scopus 로고
    • Clinical test of a new method for atrial autocapture
    • abstract
    • Kay G, Zhang G, Hall J, et al. Clinical test of a new method for atrial autocapture. (abstract) PACE 2000; 23:636.
    • (2000) PACE , vol.23 , pp. 636
    • Kay, G.1    Zhang, G.2    Hall, J.3
  • 12
    • 0034770761 scopus 로고    scopus 로고
    • Clinical validation of new pacing-sensing configurations for atrial automatic capture verification in pacemakers
    • Butter C, Hartung W, Kay G, et al. Clinical validation of new pacing-sensing configurations for atrial automatic capture verification in pacemakers. J Cardiovasc Electrophysiol 2001; 12(10):1104-1108.
    • (2001) J Cardiovasc Electrophysiol , vol.12 , Issue.10 , pp. 1104-1108
    • Butter, C.1    Hartung, W.2    Kay, G.3
  • 13
    • 0348112896 scopus 로고    scopus 로고
    • Automatic measurement of atrial pacing thresholds by AV conduction
    • abstract
    • Rueter J, Heymen H, Meisel E, et al. Automatic measurement of atrial pacing thresholds by AV conduction. (abstract) PACE 2000; 23:658.
    • (2000) PACE , vol.23 , pp. 658
    • Rueter, J.1    Heymen, H.2    Meisel, E.3
  • 14
    • 0348112897 scopus 로고    scopus 로고
    • Atrial threshold measurement using atrial chamber reset method
    • abstract
    • Sheldon T, Nelson L, Vatterott P, et al. Atrial threshold measurement using atrial chamber reset method. (abstract) PACE 2000; 23:634.
    • (2000) PACE , vol.23 , pp. 634
    • Sheldon, T.1    Nelson, L.2    Vatterott, P.3
  • 15
    • 0027055958 scopus 로고
    • A comparison of two techniques for the elimination of post-stimulus polarization potentials
    • Baig M, Walton C, Economides A, et al. A comparison of two techniques for the elimination of post-stimulus polarization potentials. EUR. J.C.P.E. 1992; 2:31-40.
    • (1992) EUR. J.C.P.E. , vol.2 , pp. 31-40
    • Baig, M.1    Walton, C.2    Economides, A.3
  • 16
    • 0346101480 scopus 로고    scopus 로고
    • Clinical experience with an automatic threshold tracking algorithm study
    • Kennergren C, Larsson B, Uhrenius A, et al. Clinical experience with an automatic threshold tracking algorithm study. PACE 2003; 26:2219-2224.
    • (2003) PACE , vol.26 , pp. 2219-2224
    • Kennergren, C.1    Larsson, B.2    Uhrenius, A.3
  • 17
    • 0346852280 scopus 로고    scopus 로고
    • Atrial evoked response and polarization evaluated in a pacing system with an onboard A/D converter
    • abstract
    • Jalali L, Florio J, Bornzin G, et al. Atrial evoked response and polarization evaluated in a pacing system with an onboard A/D converter. (abstract) PACE 1997; 20:1096.
    • (1997) PACE , vol.20 , pp. 1096
    • Jalali, L.1    Florio, J.2    Bornzin, G.3
  • 18
    • 0037252955 scopus 로고    scopus 로고
    • Atrial evoked response integral for automatic capture verification in atrial pacing
    • Boriani G, Biffi M, Cameron D, et al. Atrial evoked response integral for automatic capture verification in atrial pacing. PACE 2003; 26:243-252.
    • (2003) PACE , vol.26 , pp. 243-252
    • Boriani, G.1    Biffi, M.2    Cameron, D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.