-
3
-
-
5844384521
-
Thermal Management of Office Data Processing Centers
-
Schmidt, R., 1997, "Thermal Management of Office Data Processing Centers", Proceedings of InterPACK 1997, pp. 1995-2010.
-
(1997)
Proceedings of InterPACK 1997
, pp. 1995-2010
-
-
Schmidt, R.1
-
4
-
-
0346280209
-
Computational Fluid Dynamics Modeling of High Compute Density Data Centers to Assure System Inlet Air Specifications
-
July, Kauai, Hawaii
-
Patel, C.D., Bash, C.E., Belady, C., Stahl, L., Sullivan, D., July 2001, "Computational Fluid Dynamics Modeling of High Compute Density Data Centers to Assure System Inlet Air Specifications", Proceedings of IPACK'01 - The PacificRim/ASME International Electronics Packaging Technical Conference and Exhibition, Kauai, Hawaii.
-
(2001)
Proceedings of IPACK'01 - The PacificRim/ASME International Electronics Packaging Technical Conference and Exhibition
-
-
Patel, C.D.1
Bash, C.E.2
Belady, C.3
Stahl, L.4
Sullivan, D.5
-
5
-
-
84950137260
-
Raised Floor Computer Data Center: Effect on Rack Inlet Temperatures of Chilled Air Exiting both Hot and Cold Aisles
-
May, San Diego, California
-
Schmidt, R. and Cruz, E., May 2002, "Raised Floor Computer Data Center: Effect on Rack Inlet Temperatures of Chilled Air Exiting both Hot and Cold Aisles", ITherm 2002 - Eighth Intersociety Conference on Thermal and Thermomechanical Phenomena in Electronic Systems, San Diego, California.
-
(2002)
ITherm 2002 - Eighth Intersociety Conference on Thermal and Thermomechanical Phenomena in Electronic Systems
-
-
Schmidt, R.1
Cruz, E.2
-
6
-
-
84950136782
-
Thermal Considerations in Cooling Large Scale High Compute Density Data Centers
-
May, San Diego, California
-
Patel, C.D., Sharma, R.K., Bash, C.E., Beitelmal, A., May 2002, "Thermal Considerations in Cooling Large Scale High Compute Density Data Centers", ITherm 2002 - Eighth Intersociety Conference on Thermal and Thermomechanical Phenomena in Electronic Systems, San Diego, California.
-
(2002)
ITherm 2002 - Eighth Intersociety Conference on Thermal and Thermomechanical Phenomena in Electronic Systems
-
-
Patel, C.D.1
Sharma, R.K.2
Bash, C.E.3
Beitelmal, A.4
-
7
-
-
0035364736
-
A Methodology for the Design of Perforated Tiles in Raised Floor Data Centers Using Computational Flow Analysis
-
June
-
Kang, S., Schmidt, R., Kelkar, K., Patankar, S., "A Methodology for the Design of Perforated Tiles in Raised Floor Data Centers Using Computational Flow Analysis", IEEE-CPMT Journal, Vol. 24, No. 2, pp. 177-183, June 2001.
-
(2001)
IEEE-CPMT Journal
, vol.24
, Issue.2
, pp. 177-183
-
-
Kang, S.1
Schmidt, R.2
Kelkar, K.3
Patankar, S.4
-
8
-
-
84862049629
-
-
Flomerics Ltd., 81 Bridge Road, Hampton Court, Surrey KT8 9HH, UK
-
FLOVENT V4.1 Software by Flomerics, Flomerics Ltd., 81 Bridge Road, Hampton Court, Surrey KT8 9HH, UK, http://www.flomerics.com
-
FLOVENT V4.1 Software by Flomerics
-
-
-
9
-
-
84897584609
-
Dimensionless Parameters for Evaluation of Thermal Design and Performance in Large Scale Data Centers
-
June, St. Louis, Missouri
-
Sharma, R.K, Bash, C.E., Patel, C.D., June 2002, "Dimensionless Parameters for Evaluation of Thermal Design and Performance in Large Scale Data Centers", 8th AIAA/ASME Joint Thermophysics and Heat Transfer Conference, St. Louis, Missouri.
-
(2002)
8th AIAA/ASME Joint Thermophysics and Heat Transfer Conference
-
-
Sharma, R.K.1
Bash, C.E.2
Patel, C.D.3
-
10
-
-
78649303429
-
Numerical Optimization of Flow Resistance Distribution in an Active-Ceiling Cleanroom Plenum using CFD Techniques
-
Phoenix, Arizona
-
B. Blackmore, 2001. Numerical Optimization of Flow Resistance Distribution in an Active-Ceiling Cleanroom Plenum using CFD Techniques, Presented at IEST conference, Phoenix, Arizona.
-
(2001)
IEST Conference
-
-
Blackmore, B.1
|