Volumn 20, Issue 1, 2005, Pages 101-107

Retrieval study of tibial baseplate fracture after total knee arthroplasty

Author keywords

metallic wear; revision; tibial baseplate; total knee arthroplasty

Indexed keywords

POLYETHYLENE;

EID: 12344270823     PISSN: 08835403     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.arth.2004.09.033     Document Type: Article
Times cited : (18)

References (37)
  • 1
    • 0020057143 scopus 로고
    • Principles of surgical technique in knee arthroplasty
    • W.N. Scott, and A.J. Tria Principles of surgical technique in knee arthroplasty Orthop. Clin. North Am. 13 1982 17
    • (1982) Orthop. Clin. North Am. , vol.13 , pp. 17
    • Scott, W.N.1    Tria, A.J.2
  • 2
    • 12344331016 scopus 로고
    • Biomechanics
    • B.F. Morrey Churchill Livingstone New York
    • P.S. Walker Biomechanics B.F. Morrey Joint replacement arthroplasty 1991 Churchill Livingstone New York 959
    • (1991) Joint Replacement Arthroplasty , pp. 959
    • Walker, P.S.1
  • 3
    • 12344277189 scopus 로고
    • The biomechanics of total knee failure
    • W.N. Scott Grune and Stratton Orlando
    • T.M. Wright, and D.T. Reilly The biomechanics of total knee failure W.N. Scott Total knee revision arthroplasty 1987 Grune and Stratton Orlando 35
    • (1987) Total Knee Revision Arthroplasty , pp. 35
    • Wright, T.M.1    Reilly, D.T.2
  • 4
    • 0031544587 scopus 로고    scopus 로고
    • Wear in retrieved condylar knee arthroplasties. A comparison of wear in different designs of 280 retrieved condylar knee prostheses
    • G.W. Blunn, A.B. Joshi, and R.J. Minns Wear in retrieved condylar knee arthroplasties. A comparison of wear in different designs of 280 retrieved condylar knee prostheses J. Arthroplasty 12 1997 281
    • (1997) J. Arthroplasty , vol.12 , pp. 281
    • Blunn, G.W.1    Joshi, A.B.2    Minns, R.J.3
  • 5
    • 0025947894 scopus 로고
    • Radiographic detection of metal-induced synovitis as a complication of arthroplasty of the knee
    • B.N. Weissman, R.D. Scott, and G.W. Brick Radiographic detection of metal-induced synovitis as a complication of arthroplasty of the knee J. Bone Joint Surg. 73A 1991 1002
    • (1991) J. Bone Joint Surg. , vol.73 , pp. 1002
    • Weissman, B.N.1    Scott, R.D.2    Brick, G.W.3
  • 6
    • 0029984518 scopus 로고    scopus 로고
    • Fracture of the metal tibial tray after kinematic total knee replacement: A common cause of early aseptic failure
    • P.J. Abernethy, C.M. Robinson, and R.M. Fowler Fracture of the metal tibial tray after kinematic total knee replacement: a common cause of early aseptic failure J. Bone Joint Surg. 78B 1996 220
    • (1996) J. Bone Joint Surg. , vol.78 , pp. 220
    • Abernethy, P.J.1    Robinson, C.M.2    Fowler, R.M.3
  • 7
    • 0032951980 scopus 로고    scopus 로고
    • Fracture of the tibial tray after total knee arthroplasty
    • F. Altinas, N. Sener, and E. Ugutmen Fracture of the tibial tray after total knee arthroplasty J. Arthroplasty 14 1999 112
    • (1999) J. Arthroplasty , vol.14 , pp. 112
    • Altinas, F.1    Sener, N.2    Ugutmen, E.3
  • 8
    • 0019985937 scopus 로고
    • Revision total knee arthroplasty
    • R.S. Bryan, and J.A. Rand Revision total knee arthroplasty Clin. Orthop. 170 1982 116
    • (1982) Clin. Orthop. , vol.170 , pp. 116
    • Bryan, R.S.1    Rand, J.A.2
  • 9
    • 0025956699 scopus 로고
    • Fatigue failure of non-cemented porous-coated implants. A retrieval study
    • S.D. Cook, and K.A. Thomas Fatigue failure of non-cemented porous-coated implants. A retrieval study J. Bone Joint Surg. 73B 1991 20
    • (1991) J. Bone Joint Surg. , vol.73 , pp. 20
    • Cook, S.D.1    Thomas, K.A.2
  • 10
    • 0022389660 scopus 로고
    • Granulomatous reaction and cystic boney destruction associated with high wear rate in a total knee prosthesis
    • W.C. Dannenmaier, D.W. Haybnes, and C.L. Nelson Granulomatous reaction and cystic boney destruction associated with high wear rate in a total knee prosthesis Clin. Orthop. 198 1985 224
    • (1985) Clin. Orthop. , vol.198 , pp. 224
    • Dannenmaier, W.C.1    Haybnes, D.W.2    Nelson, C.L.3
  • 11
    • 0027954306 scopus 로고
    • Progressive subluxation and polyethylene wear in total knee replacement with flat articular surfaces
    • E.L. Feng, S.D. Stulberg, and R.L. Wixson Progressive subluxation and polyethylene wear in total knee replacement with flat articular surfaces Clin. Orthop. 229 1994 60
    • (1994) Clin. Orthop. , vol.229 , pp. 60
    • Feng, E.L.1    Stulberg, S.D.2    Wixson, R.L.3
  • 12
    • 0025220570 scopus 로고
    • Fracture of the tibial tray of the PCA Knee. A case report of early failure caused by improper design
    • G. Flivik, P. Ljung, and U. Rydholm Fracture of the tibial tray of the PCA Knee. A case report of early failure caused by improper design Acta Orthop. Scand. 61 1990 26
    • (1990) Acta Orthop. Scand. , vol.61 , pp. 26
    • Flivik, G.1    Ljung, P.2    Rydholm, U.3
  • 13
    • 0024564194 scopus 로고
    • Fracture of a fenestrated metal backing of a tibial knee component. A case report
    • I.A. Gradisar, M.L. Hoffman, and M.J. Askew Fracture of a fenestrated metal backing of a tibial knee component. A case report J. Arthroplasty 4 1989 27
    • (1989) J. Arthroplasty , vol.4 , pp. 27
    • Gradisar, I.A.1    Hoffman, M.L.2    Askew, M.J.3
  • 14
    • 0024043440 scopus 로고
    • Polyethylene wear: A cause of failure of the variable-axis total knee prosthesis. A report of three cases
    • D.R. Graham Polyethylene wear: a cause of failure of the variable-axis total knee prosthesis. A report of three cases J. Bone Joint Surg. 70A 1988 942
    • (1988) J. Bone Joint Surg. , vol.70 , pp. 942
    • Graham, D.R.1
  • 15
    • 0025521591 scopus 로고
    • Mechanical loading and biomechanical problems of total joint surface replacement of the tibial plateau
    • V. Jansson Mechanische belastung und biomechanische probleme des kompletten gelekflachenersatzes beim tibiaplateau Mechanical loading and biomechanical problems of total joint surface replacement of the tibial plateau Z. Orthop. 128 1990 606
    • (1990) Z. Orthop. , vol.128 , pp. 606
    • Jansson, V.1
  • 17
    • 0028105074 scopus 로고
    • Fracture of the tibial tray following PCA knee replacement. A report of two cases
    • M. Maruyama, K. Terayama, and H. Sunohara Fracture of the tibial tray following PCA knee replacement. A report of two cases Arch. Orthop. Trauma. Surg. 113 1994 330
    • (1994) Arch. Orthop. Trauma. Surg. , vol.113 , pp. 330
    • Maruyama, M.1    Terayama, K.2    Sunohara, H.3
  • 18
    • 0021368155 scopus 로고
    • Breakage of the metal tray in total knee replacement
    • D.G. Mendes, D. Brandon, and L. Galor Breakage of the metal tray in total knee replacement Orthopedics 7 1984 860
    • (1984) Orthopedics , vol.7 , pp. 860
    • Mendes, D.G.1    Brandon, D.2    Galor, L.3
  • 19
    • 0023835093 scopus 로고
    • Mechanisms of failure in total knee arthroplasty
    • J.R. Moreland Mechanisms of failure in total knee arthroplasty Clin. Orthop. 226 1988 49
    • (1988) Clin. Orthop. , vol.226 , pp. 49
    • Moreland, J.R.1
  • 20
    • 0023934953 scopus 로고
    • Fracture of the porous-coated metal tray of a biologically fixed knee prosthesis. Report of a case
    • B.F. Morrey, and E.Y.S. Chao Fracture of the porous-coated metal tray of a biologically fixed knee prosthesis. Report of a case Clin. Orth. 228 1988 182
    • (1988) Clin. Orth. , vol.228 , pp. 182
    • Morrey, B.F.1    Chao, E.Y.S.2
  • 21
    • 0022470268 scopus 로고
    • Retrieval analysis of porous-coated components for total knee arthroplasty. A report of two cases
    • C.S. Ranawat, N.A. Johanson, and C.M. Rimnac Retrieval analysis of porous-coated components for total knee arthroplasty. A report of two cases Clin. Orthop. 209 1986 244
    • (1986) Clin. Orthop. , vol.209 , pp. 244
    • Ranawat, C.S.1    Johanson, N.A.2    Rimnac, C.M.3
  • 22
    • 12344285527 scopus 로고
    • Factors leading to metal tibial component fracture
    • K. Rintz, A. Tsao, and J. Gilbert Factors leading to metal tibial component fracture Orthop. Trans. 14 1990 619
    • (1990) Orthop. Trans. , vol.14 , pp. 619
    • Rintz, K.1    Tsao, A.2    Gilbert, J.3
  • 23
    • 0021271401 scopus 로고
    • Fracture of metallic tibial tray following total knee replacement. Report of two cases
    • R.D. Scott, F.C. Ewald, and P.S. Walker Fracture of metallic tibial tray following total knee replacement. Report of two cases J. Bone Joint Surg. 66A 1984 780
    • (1984) J. Bone Joint Surg. , vol.66 , pp. 780
    • Scott, R.D.1    Ewald, F.C.2    Walker, P.S.3
  • 24
    • 0025126477 scopus 로고
    • Total knee arthroplasty with the kinematic prosthesis. Results after five to nine years: A follow-up note
    • J. Wright, F.C. Ewald, and P.S. Walker Total knee arthroplasty with the kinematic prosthesis. Results after five to nine years: a follow-up note J. Bone Joint Surg. 72A 1990 1003
    • (1990) J. Bone Joint Surg. , vol.72 , pp. 1003
    • Wright, J.1    Ewald, F.C.2    Walker, P.S.3
  • 25
    • 0023766181 scopus 로고
    • Fracture of the femoral component. Analysis of failure and long term follow up of revision
    • J.J. Callaghan, P.M. Pellicci, and E.A. Salvati Fracture of the femoral component. Analysis of failure and long term follow up of revision Orthop. Clin. North Am. 19 1988 637
    • (1988) Orthop. Clin. North Am. , vol.19 , pp. 637
    • Callaghan, J.J.1    Pellicci, P.M.2    Salvati, E.A.3
  • 26
    • 0020617863 scopus 로고
    • Powder metal made orthopaedic implants with porous surface for ingrowth
    • R.M. Pilliar Powder metal made orthopaedic implants with porous surface for ingrowth Clin. Orthop. 176 1983 42
    • (1983) Clin. Orthop. , vol.176 , pp. 42
    • Pilliar, R.M.1
  • 27
    • 0026350108 scopus 로고
    • The dominance of cyclic sliding in producing wear in total knee replacements
    • G.W. Blunn, P.S. Walker, and A. Joshi The dominance of cyclic sliding in producing wear in total knee replacements Clin. Orthop. 273 1991 253
    • (1991) Clin. Orthop. , vol.273 , pp. 253
    • Blunn, G.W.1    Walker, P.S.2    Joshi, A.3
  • 28
    • 0022504260 scopus 로고
    • The problem of surface damage in polyethylene total knee components
    • T.M. Wright, and D.L. Bartel The problem of surface damage in polyethylene total knee components Clin. Orthop. 205 1986 67
    • (1986) Clin. Orthop. , vol.205 , pp. 67
    • Wright, T.M.1    Bartel, D.L.2
  • 29
    • 0023007566 scopus 로고
    • The effect of conformity, thickness and material stresses in ultra high molecular weight components for total joint replacement
    • D.L. Bartel, V.L. Bicknell, and T.M. Wright The effect of conformity, thickness and material stresses in ultra high molecular weight components for total joint replacement J. Bone Joint Surg. 68A 1986 1041
    • (1986) J. Bone Joint Surg. , vol.68 , pp. 1041
    • Bartel, D.L.1    Bicknell, V.L.2    Wright, T.M.3
  • 30
    • 0028008566 scopus 로고
    • Posteromedial tibial polyethylene failure in total knee replacement
    • P. Lewis, C.H. Rorabeck, and R.B. Bourne Posteromedial tibial polyethylene failure in total knee replacement Clin. Orthop. 299 1994 11
    • (1994) Clin. Orthop. , vol.299 , pp. 11
    • Lewis, P.1    Rorabeck, C.H.2    Bourne, R.B.3
  • 31
    • 0027326133 scopus 로고
    • Posterior polyethylene wear in posterior cruciate ligament retaining total knee arthroplasty: A case study
    • M.R. Swany, and R.D. Scott Posterior polyethylene wear in posterior cruciate ligament retaining total knee arthroplasty: a case study J. Arthroplasty 8 1993 439
    • (1993) J. Arthroplasty , vol.8 , pp. 439
    • Swany, M.R.1    Scott, R.D.2
  • 32
    • 0027375369 scopus 로고
    • Increased varus-valgus tilting of screw-fixated knee prostheses: Stereoradiographic study of uncemented versus cemented tibial components
    • K. Nilsson, and J. Karrholm Increased varus-valgus tilting of screw-fixated knee prostheses: stereoradiographic study of uncemented versus cemented tibial components J. Arthroplasty 8 1993 529
    • (1993) J. Arthroplasty , vol.8 , pp. 529
    • Nilsson, K.1    Karrholm, J.2
  • 33
    • 0035109241 scopus 로고    scopus 로고
    • Femoral condylar lift off in vivo in total knee arthroplasty
    • D. Dennis, R. Komistek, and S. Walker Femoral condylar lift off in vivo in total knee arthroplasty J. Bone Joint Surg. 83B 2001 33
    • (2001) J. Bone Joint Surg. , vol.83 , pp. 33
    • Dennis, D.1    Komistek, R.2    Walker, S.3
  • 34
    • 0032791992 scopus 로고    scopus 로고
    • Detrimental kinematics of a flat on flat total condylar knee arthroplasty
    • J. Stiehl, R. Komistek, and D. Dennis Detrimental kinematics of a flat on flat total condylar knee arthroplasty Clin. Orthop. 365 1999 139
    • (1999) Clin. Orthop. , vol.365 , pp. 139
    • Stiehl, J.1    Komistek, R.2    Dennis, D.3
  • 36
    • 0018859548 scopus 로고
    • Distribution of load across the knee: A comparison of static and dynamic measurements
    • F. Johnson, S. Leitl, and W. Waugh Distribution of load across the knee: a comparison of static and dynamic measurements J. Bone Joint Surg. 62B 1980 346
    • (1980) J. Bone Joint Surg. , vol.62 , pp. 346
    • Johnson, F.1    Leitl, S.2    Waugh, W.3
  • 37
    • 0020694705 scopus 로고
    • Static and dynamic loading patterns in knee joints with deformity
    • I.J. Harrington Static and dynamic loading patterns in knee joints with deformity J. Bone Joint Surg. 65A 1983 247
    • (1983) J. Bone Joint Surg. , vol.65 , pp. 247
    • Harrington, I.J.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.