메뉴 건너뛰기




Volumn 26, Issue 19, 2005, Pages 4129-4138

A comparative radiological assessment of polylactide pins over 3 years in vivo

Author keywords

Biodegradation; Calcium phosphate; Composite; Osteolysis; Polylactic acid

Indexed keywords

BIOCOMPATIBILITY; BIODEGRADATION; BONE; CALCIUM COMPOUNDS; COMPUTERIZED TOMOGRAPHY; DENTAL PROSTHESES; FRACTURE FIXATION; HISTOLOGY; MICROSCOPIC EXAMINATION; ORGANIC POLYMERS; TISSUE;

EID: 12344257887     PISSN: 01429612     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.biomaterials.2004.10.031     Document Type: Article
Times cited : (21)

References (30)
  • 1
    • 2942592481 scopus 로고    scopus 로고
    • Bioabsorbable implants: Review of clinical experience in orthopedic surgery
    • C.G. Ambrose, and T.O. Clanton Bioabsorbable implants review of clinical experience in orthopedic surgery Ann Biomed Eng 32 2004 171 177
    • (2004) Ann Biomed Eng , vol.32 , pp. 171-177
    • Ambrose, C.G.1    Clanton, T.O.2
  • 3
    • 0031262523 scopus 로고    scopus 로고
    • Bioresorbable fracture fixation in orthopedics: A comprehensive review
    • J.A. Simon, J.L. Ricci, and P.E. Di Cesari Bioresorbable fracture fixation in orthopedics a comprehensive review Am J Orthop 11 1997 754 762
    • (1997) Am J Orthop , vol.11 , pp. 754-762
    • Simon, J.A.1    Ricci, J.L.2    Di Cesari, P.E.3
  • 5
    • 0034997252 scopus 로고    scopus 로고
    • Causes of the clinical tissue response to polyglycolide and polylactide implants with an emphasis on the knee
    • P. Tuompo, E.K. Partio, H.P.K. Jukkula-Partio, E. Hirvensalo, and P. Rokkanen Causes of the clinical tissue response to polyglycolide and polylactide implants with an emphasis on the knee Arch Orthop Trauma Surg 121 2001 261 264
    • (2001) Arch Orthop Trauma Surg , vol.121 , pp. 261-264
    • Tuompo, P.1    Partio, E.K.2    Jukkula-Partio, H.P.K.3    Hirvensalo, E.4    Rokkanen, P.5
  • 6
    • 0031202409 scopus 로고    scopus 로고
    • Local foreign-body reactions to biodegradable implants - A classification system
    • R. Hoffmann, A. Weiler, H.J. Helling, C. Krettek, and K.E. Rehm Local foreign-body reactions to biodegradable implants - a classification system Unfallchirurg 100 1997 658 666
    • (1997) Unfallchirurg , vol.100 , pp. 658-666
    • Hoffmann, R.1    Weiler, A.2    Helling, H.J.3    Krettek, C.4    Rehm, K.E.5
  • 8
    • 0029891715 scopus 로고    scopus 로고
    • Foreign-body reaction and the course of osteolysis after Polyglycolide implants for fracture fixation
    • A. Weiler, H.J. Helling, U. Kirch, T.K. Zirbes, and K.E. Rehm Foreign-body reaction and the course of osteolysis after Polyglycolide implants for fracture fixation J Bone Joint Surg 78B 1996 369 376
    • (1996) J Bone Joint Surg , vol.78 , pp. 369-376
    • Weiler, A.1    Helling, H.J.2    Kirch, U.3    Zirbes, T.K.4    Rehm, K.E.5
  • 9
    • 0025334647 scopus 로고
    • Foreign-body reactions to fracture fixation implants of biodegradable synthetic polymers
    • O. Böstman, E. Hirvensalo, J. Mäkinen, and P. Rokkanen Foreign-body reactions to fracture fixation implants of biodegradable synthetic polymers J Bone Joint Surg 72B 1990 592 596
    • (1990) J Bone Joint Surg , vol.72 , pp. 592-596
    • Böstman, O.1    Hirvensalo, E.2    Mäkinen, J.3    Rokkanen, P.4
  • 10
    • 0026473093 scopus 로고
    • Biodegradable rods versus Kirschner wire fixation of wrist fractures: A randomised trial
    • P.P. Casteleyn, F. Handelberg, and P. Haentjes Biodegradable rods versus Kirschner wire fixation of wrist fractures a randomised trial J Bone Joint Surg 74B 1992 858 861
    • (1992) J Bone Joint Surg , vol.74 , pp. 858-861
    • Casteleyn, P.P.1    Handelberg, F.2    Haentjes, P.3
  • 11
    • 0030997311 scopus 로고    scopus 로고
    • New developments in the application of biodegradable implants
    • K.E. Rehm, H.J. Helling, and C. Gatzka New developments in the application of biodegradable implants Orthopaede 26 1997 489 497
    • (1997) Orthopaede , vol.26 , pp. 489-497
    • Rehm, K.E.1    Helling, H.J.2    Gatzka, C.3
  • 12
    • 0026996669 scopus 로고
    • In vitro and in vivo studies on bioabsorbable ultra-high-strength poly (l-lactide) rods
    • Y. Matsusue, T. Yamamuro, M. Oka, Y. Shikinami, S.H. Hyon, and Y. Ikada In vitro and in vivo studies on bioabsorbable ultra-high-strength poly (l-lactide) rods J Biomed Mater Res 26 1992 1553 1567
    • (1992) J Biomed Mater Res , vol.26 , pp. 1553-1567
    • Matsusue, Y.1    Yamamuro, T.2    Oka, M.3    Shikinami, Y.4    Hyon, S.H.5    Ikada, Y.6
  • 13
    • 0029120601 scopus 로고
    • Tissue reaction of bioabsorbable ultra high strength oply (l-lactid) rod. A long term study in rabbits
    • Y. Matsusue, S. Hanafusa, T. Yamamuro, Y. Shikinami, and Y. Ikada Tissue reaction of bioabsorbable ultra high strength oply (l-lactid) rod. A long term study in rabbits Clin Orthop Relat Res 317 1995 246 253
    • (1995) Clin Orthop Relat Res , vol.317 , pp. 246-253
    • Matsusue, Y.1    Hanafusa, S.2    Yamamuro, T.3    Shikinami, Y.4    Ikada, Y.5
  • 14
    • 0031949295 scopus 로고    scopus 로고
    • A 5-year in vitro and in vivo study of the biodegradation of polylactide plates
    • R. Suuronen, T. Pohjonen, J. Hietanen, and C. Lindqvist A 5-year in vitro and in vivo study of the biodegradation of polylactide plates J Oral Maxillofac Surg 56 1998 604 614
    • (1998) J Oral Maxillofac Surg , vol.56 , pp. 604-614
    • Suuronen, R.1    Pohjonen, T.2    Hietanen, J.3    Lindqvist, C.4
  • 16
    • 0035998354 scopus 로고    scopus 로고
    • Transmission electron microscopic visualization of the degradation and phagocytosis of a poly-l-lactide screw in cancellous bone: A long term experimental study
    • O. Laitinen, H. Pihlajamäki, A. Sukura, and O. Böstman Transmission electron microscopic visualization of the degradation and phagocytosis of a poly-l-lactide screw in cancellous bone a long term experimental study J Biomed Mater Res 61 2002 33 39
    • (2002) J Biomed Mater Res , vol.61 , pp. 33-39
    • Laitinen, O.1    Pihlajamäki, H.2    Sukura, A.3    Böstman, O.4
  • 17
    • 0036436263 scopus 로고    scopus 로고
    • The long term behavior of poly-l-lactide screws in a minipig fracture model: Preliminary report
    • Y. Hasegawa, S. Sakano, T. Iwase, and H. Warashina The long term behavior of poly-l-lactide screws in a minipig fracture model preliminary report J Biomed Mater Res 63 2002 679 685
    • (2002) J Biomed Mater Res , vol.63 , pp. 679-685
    • Hasegawa, Y.1    Sakano, S.2    Iwase, T.3    Warashina, H.4
  • 18
    • 0030209083 scopus 로고    scopus 로고
    • New bioresorbable pin for the reduction of small bony fragments: Design, mechanical properties and in vitro degradation
    • L.E. Claes, A.A. Ignatius, K.E. Rehm, and C. Scholz New bioresorbable pin for the reduction of small bony fragments design, mechanical properties and in vitro degradation Biomaterials 17 1996 1621 1626
    • (1996) Biomaterials , vol.17 , pp. 1621-1626
    • Claes, L.E.1    Ignatius, A.A.2    Rehm, K.E.3    Scholz, C.4
  • 20
    • 0034980994 scopus 로고    scopus 로고
    • Degradation behavior of Composite pins made of tricalcium phosphate and poly(l,dl-lactide) or the reduction of small bony fragments
    • A.A. Ignatius, P. Augat, and L.E. Claes Degradation behavior of Composite pins made of tricalcium phosphate and poly(l,dl-lactide) or the reduction of small bony fragments J Biomater Sci Polym Ed 12 2001 185 194
    • (2001) J Biomater Sci: Polym Ed , vol.12 , pp. 185-194
    • Ignatius, A.A.1    Augat, P.2    Claes, L.E.3
  • 21
    • 0034446599 scopus 로고    scopus 로고
    • Bioresorbable polymers in trauma and bone surgery
    • Gogolewski S. Bioresorbable polymers in trauma and bone surgery. Int J Care Injured 2000; 31: S-D28-D32.
    • (2000) Int J Care Injured , vol.31
    • Gogolewski, S.1
  • 22
    • 0030061447 scopus 로고    scopus 로고
    • Sterilization, toxicity, biocompatibility and clinical applications of polylactic acid/polyglycolic acid copolymers
    • K.A. Athanasiou, G.G. Niederauer, and C.M. Agrawal Sterilization, toxicity, biocompatibility and clinical applications of polylactic acid/polyglycolic acid copolymers Biomaterials 17 1996 93 102
    • (1996) Biomaterials , vol.17 , pp. 93-102
    • Athanasiou, K.A.1    Niederauer, G.G.2    Agrawal, C.M.3
  • 23
    • 0038051473 scopus 로고    scopus 로고
    • Adverse tissue reactions to bioabsorbable fixation devices
    • O.M. Böstman, and H.K. Pihlajamaki Adverse tissue reactions to bioabsorbable fixation devices Clin Orthop 221 2000 216 227
    • (2000) Clin Orthop , vol.221 , pp. 216-227
    • Böstman, O.M.1    Pihlajamaki, H.K.2
  • 24
    • 0028878553 scopus 로고
    • Late degradation tissue response to poly(l-lactide) bone plates and screws
    • J.E. Bergsma, W.C. Bruin, F.R. Rozem, R.R. Bos, and G. Boeing Late degradation tissue response to poly(l-lactide) bone plates and screws Biomaterials 16 1995 25 31
    • (1995) Biomaterials , vol.16 , pp. 25-31
    • Bergsma, J.E.1    Bruin, W.C.2    Rozem, F.R.3    Bos, R.R.4    Boeing, G.5
  • 25
    • 0035462850 scopus 로고    scopus 로고
    • Bioabsorbable implants in orthopaedics: New developments and clinical applications
    • W.J. Ciccone, C. Motz, C. Bentley, and J.P. Tasto Bioabsorbable implants in orthopaedics new developments and clinical applications J Am Acad Orthop Surg 9 2001 280 288
    • (2001) J Am Acad Orthop Surg , vol.9 , pp. 280-288
    • Ciccone, W.J.1    Motz, C.2    Bentley, C.3    Tasto, J.P.4
  • 27
    • 0034029863 scopus 로고    scopus 로고
    • Histomorphometric study on high-strength hydoxyapatite/poly(l-lactide) composite rods for internal fixation of bone fractures
    • T. Furukawa, Y. Matsusue, T. Yasungaga, Y. Nakagawa, Y. Okada, Y. Shikinami, M. Okuno, and T. Nakamura Histomorphometric study on high-strength hydoxyapatite/poly(l-lactide) composite rods for internal fixation of bone fractures J Biomed Mater Res 50 2000 410 419
    • (2000) J Biomed Mater Res , vol.50 , pp. 410-419
    • Furukawa, T.1    Matsusue, Y.2    Yasungaga, T.3    Nakagawa, Y.4    Okada, Y.5    Shikinami, Y.6    Okuno, M.7    Nakamura, T.8
  • 28


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.