메뉴 건너뛰기




Volumn 5, Issue 13, 2004, Pages 47-54

High-speed confocal laser scanning microscopy using acousto-optic deflectors and a digital micromirror device

Author keywords

Acousto optic deflector; AOD; Confocal; Digital micromirror device; DMD; Neuron

Indexed keywords

ALGORITHMS; CELLS; CHARGE COUPLED DEVICES; DATA ACQUISITION; DIGITAL DEVICES; NEUROLOGY; OPTICAL RECORDING; PHOTOACOUSTIC EFFECT; SIGNAL TO NOISE RATIO;

EID: 12144262770     PISSN: 16057422     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.529432     Document Type: Conference Paper
Times cited : (8)

References (15)
  • 1
    • 0034721728 scopus 로고    scopus 로고
    • Diversity and dynamics of dendritic signaling
    • Hausser,M., Spruston,N., and Stuart,G.J., "Diversity and Dynamics of Dendritic Signaling." Science, 290, pp. 739-744, 2000.
    • (2000) Science , vol.290 , pp. 739-744
    • Hausser, M.1    Spruston, N.2    Stuart, G.J.3
  • 2
    • 0029031269 scopus 로고
    • Probing dendritic function with patch pipettes
    • Stuart,G. and Spruston,N., "Probing Dendritic Function With Patch Pipettes." Curr.Opin.Neurobiol., 5, pp. 389-394, 1995.
    • (1995) Curr.Opin.Neurobiol. , vol.5 , pp. 389-394
    • Stuart, G.1    Spruston, N.2
  • 3
    • 0031574080 scopus 로고    scopus 로고
    • Action potential initiation and propagation in rat neocortical pyramidal neurons
    • Stuart,G., Schiller,J., and Sakmann,B., "Action Potential Initiation and Propagation in Rat Neocortical Pyramidal Neurons." J Physiol (Lond), 505, pp. 617-632, 1997.
    • (1997) J Physiol (Lond) , vol.505 , pp. 617-632
    • Stuart, G.1    Schiller, J.2    Sakmann, B.3
  • 4
    • 0031574079 scopus 로고    scopus 로고
    • Calcium action potentials restricted to distal apical dendrites of rat neocortical pyramidal neurons
    • Schiller,J., Schiller,Y., Stuart,G., and Sakmann,B., "Calcium Action Potentials Restricted to Distal Apical Dendrites of Rat Neocortical Pyramidal Neurons." J.Physiol, 505 ( Pt 3), pp. 605-616, 1997.
    • (1997) J.Physiol , vol.505 , Issue.PART 3 , pp. 605-616
    • Schiller, J.1    Schiller, Y.2    Stuart, G.3    Sakmann, B.4
  • 5
    • 0023322209 scopus 로고
    • Optical recording of synaptic potentials from processes of single neurons using intracellular potentiometric dyes
    • Grinvald,A., Salzberg,B.M., LevRam,V., and Hildesheim,R., "Optical Recording of Synaptic Potentials From Processes of Single Neurons Using Intracellular Potentiometric Dyes." Biophys J, 51, pp. 643-651, 1987.
    • (1987) Biophys J , vol.51 , pp. 643-651
    • Grinvald, A.1    Salzberg, B.M.2    LevRam, V.3    Hildesheim, R.4
  • 6
    • 0031921955 scopus 로고    scopus 로고
    • Fast optical measurement of membrane potential changes at multiple sites on an individual nerve cell
    • Zecevic,D. and Antic,S., "Fast Optical Measurement of Membrane Potential Changes at Multiple Sites on an Individual Nerve Cell." Histochem.J., 30, pp. 197-216, 1998.
    • (1998) Histochem.J. , vol.30 , pp. 197-216
    • Zecevic, D.1    Antic, S.2
  • 7
    • 0032820593 scopus 로고    scopus 로고
    • Fast optical recordings of membrane potential changes from dendrites of pyramidal neurons
    • Antic,S., Major,G., and Zecevic,D., "Fast Optical Recordings of Membrane Potential Changes From Dendrites of Pyramidal Neurons." J.Neurophysiol., 82, pp. 1615-1621, 1999.
    • (1999) J.Neurophysiol. , vol.82 , pp. 1615-1621
    • Antic, S.1    Major, G.2    Zecevic, D.3
  • 10
    • 0030955974 scopus 로고    scopus 로고
    • High-speed, random-access fluorescence microscopy: I. High-resolution optical recording with voltage-sensitive dyes and ion indicators
    • Bullen,A., Patel,S.S., and Saggau,P., "High-Speed, Random-Access Fluorescence Microscopy: I. High-Resolution Optical Recording With Voltage-Sensitive Dyes and Ion Indicators." Biophys.J., 73, pp. 477-491, 1997.
    • (1997) Biophys.J. , vol.73 , pp. 477-491
    • Bullen, A.1    Patel, S.S.2    Saggau, P.3
  • 11
    • 0033025562 scopus 로고    scopus 로고
    • High-speed, random-access fluorescence microscopy: II. Fast quantitative measurements with voltage-sensitive dyes
    • Bullen,A. and Saggau,P., "High-Speed, Random-Access Fluorescence Microscopy: II. Fast Quantitative Measurements With Voltage-Sensitive Dyes." Biophys.J., 76, pp. 2272-2287, 1999.
    • (1999) Biophys.J. , vol.76 , pp. 2272-2287
    • Bullen, A.1    Saggau, P.2
  • 12
    • 0000238336 scopus 로고
    • A simplex method for function minimization
    • Nelder,J.A. and Mead,R., "A Simplex Method for Function Minimization." Computer J., 7, pp. 308-313, 1965.
    • (1965) Computer J. , vol.7 , pp. 308-313
    • Nelder, J.A.1    Mead, R.2
  • 14
    • 0025143229 scopus 로고
    • A confocal video-rate laser-beam scanning reflected-light microscope with no moving parts
    • Goldstein,S.R., Hubin,T., Rosenthal,S., and Washburn,C., "A Confocal Video-Rate Laser-Beam Scanning Reflected-Light Microscope With No Moving Parts." J.Microsc., 157 ( Pt 1), pp. 29-38, 1990.
    • (1990) J.Microsc. , vol.157 , Issue.PART 1 , pp. 29-38
    • Goldstein, S.R.1    Hubin, T.2    Rosenthal, S.3    Washburn, C.4
  • 15
    • 0342341970 scopus 로고
    • An improved no-moving-parts video-rate confocal microscope
    • Goldstein,S.R., Hubin,T., and Smith,T.G., "An Improved No-Moving-Parts Video-Rate Confocal Microscope." Micron.Microsc.Acta., 23, pp. 437-446, 1992.
    • (1992) Micron.Microsc.Acta. , vol.23 , pp. 437-446
    • Goldstein, S.R.1    Hubin, T.2    Smith, T.G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.