메뉴 건너뛰기




Volumn 29, Issue 4-5, 2004, Pages 357-368

The thickness of the tear film

Author keywords

Contact lens; Dry eye; Lipid layer; Tear breakup; Tear film

Indexed keywords

CORNEA; DRY EYE; EYELID REFLEX; HUMAN; LENS; MEASUREMENT; NONHUMAN; PRIORITY JOURNAL; SHORT SURVEY; TEAR FILM; THICKNESS;

EID: 11844282165     PISSN: 02713683     EISSN: None     Source Type: Journal    
DOI: 10.1080/02713680490516099     Document Type: Short Survey
Times cited : (253)

References (68)
  • 1
    • 0031055619 scopus 로고    scopus 로고
    • Importance of the lipid layer in human tear film stability and evaporation
    • Craig JP, Tomlinson A. Importance of the lipid layer in human tear film stability and evaporation. Optom Vis Sci. 1997;74:8-13.
    • (1997) Optom Vis Sci , vol.74 , pp. 8-13
    • Craig, J.P.1    Tomlinson, A.2
  • 2
    • 0029800560 scopus 로고    scopus 로고
    • Correlation of tear lipid layer interference patterns with the diagnosis and severity of dry eye
    • Yokoi N, Takehisa Y, Kinoshita S. Correlation of tear lipid layer interference patterns with the diagnosis and severity of dry eye. Am J Ophthalmol. 1996;122:818-824.
    • (1996) Am J Ophthalmol , vol.122 , pp. 818-824
    • Yokoi, N.1    Takehisa, Y.2    Kinoshita, S.3
  • 3
    • 0036286397 scopus 로고    scopus 로고
    • Evaluation of tear film interference patterns and measures of tear break-up time
    • Nichols JJ, Nichols KK, Puent B, Saracino M, Mitchell GL. Evaluation of tear film interference patterns and measures of tear break-up time. Optom Vis Sci. 2002;79:363-369.
    • (2002) Optom Vis Sci , vol.79 , pp. 363-369
    • Nichols, J.J.1    Nichols, K.K.2    Puent, B.3    Saracino, M.4    Mitchell, G.L.5
  • 4
    • 0037259140 scopus 로고    scopus 로고
    • Correlation of lipid layer thickness measurements with fluorescein tear film break-up time and Schirmer's test
    • Isreb MA, Greiner JV, Korb DR, Glonek T, Mody SS, Finnemore VM, Reddy CV. Correlation of lipid layer thickness measurements with fluorescein tear film break-up time and Schirmer's test. Eye. 2003;17:79-83.
    • (2003) Eye , vol.17 , pp. 79-83
    • Isreb, M.A.1    Greiner, J.V.2    Korb, D.R.3    Glonek, T.4    Mody, S.S.5    Finnemore, V.M.6    Reddy, C.V.7
  • 5
    • 0242668719 scopus 로고    scopus 로고
    • Kinetic analysis of tear interference images in aqueous tear deficiency dry eye before and after punctal occlusion
    • Goto E, Tseng SC. Kinetic analysis of tear interference images in aqueous tear deficiency dry eye before and after punctal occlusion. Invest Ophthalmol Vis Sci. 2003;44: 1897-1905.
    • (2003) Invest Ophthalmol Vis Sci , vol.44 , pp. 1897-1905
    • Goto, E.1    Tseng, S.C.2
  • 7
    • 0028057969 scopus 로고
    • Postlens tear film morphology, lens movement and symptoms in hydrogel lens wearers
    • Little SA, Bruce AS. Postlens tear film morphology, lens movement and symptoms in hydrogel lens wearers. Ophthalmic Physiol Opt. 1994;14:65-69.
    • (1994) Ophthalmic Physiol Opt , vol.14 , pp. 65-69
    • Little, S.A.1    Bruce, A.S.2
  • 8
    • 0037247550 scopus 로고    scopus 로고
    • Thickness of the pre- and post-contact lens tear film measured in vivo by interferometry
    • Nichols JJ, King-Smith PE. Thickness of the pre- and post-contact lens tear film measured in vivo by interferometry. Invest Ophthalmol Vis Sci. 2003;44:68-77.
    • (2003) Invest Ophthalmol Vis Sci , vol.44 , pp. 68-77
    • Nichols, J.J.1    King-Smith, P.E.2
  • 9
    • 0029930659 scopus 로고    scopus 로고
    • A new method for determining corneal epithelial barrier to fluorescein in humans
    • Joshi A, Maurice D, Paugh JR. A new method for determining corneal epithelial barrier to fluorescein in humans. Invest Ophthalmol Vis Sci. 1996;37:1008-1016.
    • (1996) Invest Ophthalmol Vis Sci , vol.37 , pp. 1008-1016
    • Joshi, A.1    Maurice, D.2    Paugh, J.R.3
  • 10
    • 0030560887 scopus 로고    scopus 로고
    • Deposition and thinning of the human tear film
    • Wong H, Fatt I, Radke CJ. Deposition and thinning of the human tear film. J Colloid Interface Sci. 1996;184:44-51.
    • (1996) J Colloid Interface Sci , vol.184 , pp. 44-51
    • Wong, H.1    Fatt, I.2    Radke, C.J.3
  • 11
    • 0015245702 scopus 로고
    • Meniscus-induced thinning of tear films
    • McDonald JE, Brubaker S. Meniscus-induced thinning of tear films. Am J Ophthalmol. 1971;72:139-146.
    • (1971) Am J Ophthalmol , vol.72 , pp. 139-146
    • McDonald, J.E.1    Brubaker, S.2
  • 12
    • 0031775165 scopus 로고    scopus 로고
    • Hydrodynamics of meniscus-induced thinning of the tear film
    • Sharma A, Tiwari S, Khanna R, Tiffany JM. Hydrodynamics of meniscus-induced thinning of the tear film. Adv Exp Med Biol. 1998;438:425-431.
    • (1998) Adv Exp Med Biol , vol.438 , pp. 425-431
    • Sharma, A.1    Tiwari, S.2    Khanna, R.3    Tiffany, J.M.4
  • 13
    • 0007528493 scopus 로고
    • The thickness of the precorneal tear film
    • Ehlers N. The thickness of the precorneal tear film. Acta Ophthalmol (Copenh). 1965;81:92-100.
    • (1965) Acta Ophthalmol (Copenh) , vol.81 , pp. 92-100
    • Ehlers, N.1
  • 14
    • 0016056128 scopus 로고
    • A surface tension gradient mechanism for driving the pre-corneal tear film after a blink
    • Berger RE, Corrsin S. A surface tension gradient mechanism for driving the pre-corneal tear film after a blink. J Biomech. 1974;7:225-238.
    • (1974) J Biomech , vol.7 , pp. 225-238
    • Berger, R.E.1    Corrsin, S.2
  • 17
    • 0021328178 scopus 로고
    • In vivo observation of tear dynamics using fluorophotometry
    • Benedetto DA, Clinch TE, Laibson PR. In vivo observation of tear dynamics using fluorophotometry. Arch Ophthalmol. 1984;102:410-412.
    • (1984) Arch Ophthalmol , vol.102 , pp. 410-412
    • Benedetto, D.A.1    Clinch, T.E.2    Laibson, P.R.3
  • 18
    • 0032030825 scopus 로고    scopus 로고
    • Viscosity-dependent fluid dynamics of eyedrops on the ocular surface
    • Shimmura S, Goto E, Shimazaki J, Tsubota K. Viscosity-dependent fluid dynamics of eyedrops on the ocular surface. Am J Ophthalmol. 1998;125:386-388.
    • (1998) Am J Ophthalmol , vol.125 , pp. 386-388
    • Shimmura, S.1    Goto, E.2    Shimazaki, J.3    Tsubota, K.4
  • 19
    • 11844286588 scopus 로고    scopus 로고
    • Is inferior tear film thinner than superior tear film?
    • Abstract 2476
    • King-Smith PE, Nichols KK, Wood JE. Is inferior tear film thinner than superior tear film? ARVO Abstracts. 2003: Abstract 2476.
    • (2003) ARVO Abstracts
    • King-Smith, P.E.1    Nichols, K.K.2    Wood, J.E.3
  • 21
    • 0036932749 scopus 로고    scopus 로고
    • Evaporation from the human tear film studied by interferometry
    • King-Smith PE, Fink BA, Hill RM. Evaporation from the human tear film studied by interferometry. Adv Exp Med Biol. 2002;506(Pt A):425-429.
    • (2002) Adv Exp Med Biol , vol.506 , Issue.PART A , pp. 425-429
    • King-Smith, P.E.1    Fink, B.A.2    Hill, R.M.3
  • 23
    • 0031608408 scopus 로고    scopus 로고
    • Interferometric measurement of tear film thickness by use of spectral oscillations
    • Fogt N, King-Smith PE, Tuell G. Interferometric measurement of tear film thickness by use of spectral oscillations. J Opt Soc Am A Opt Image Sci Vis. 1998;15:268-275.
    • (1998) J Opt Soc Am A Opt Image Sci Vis , vol.15 , pp. 268-275
    • Fogt, N.1    King-Smith, P.E.2    Tuell, G.3
  • 24
    • 0033005905 scopus 로고    scopus 로고
    • Three interferometric methods for measuring the thickness of layers of the tear film
    • King-Smith PE, Fink BA, Fogt N. Three interferometric methods for measuring the thickness of layers of the tear film. Optom Vis Sci. 1999;76:19-32.
    • (1999) Optom Vis Sci , vol.76 , pp. 19-32
    • King-Smith, P.E.1    Fink, B.A.2    Fogt, N.3
  • 25
    • 0016465234 scopus 로고
    • Corneal thickness measured by interferometry
    • Green DG, Frueh BR, Shapiro JM. Corneal thickness measured by interferometry. J Opt Soc Am. 1975;65:119-123.
    • (1975) J Opt Soc Am , vol.65 , pp. 119-123
    • Green, D.G.1    Frueh, B.R.2    Shapiro, J.M.3
  • 26
    • 0037809437 scopus 로고    scopus 로고
    • Precorneal and pre- and postlens tear film thickness measured indirectly with optical coherence tomography
    • Wang J, Fonn D, Simpson TL, Jones L. Precorneal and pre- and postlens tear film thickness measured indirectly with optical coherence tomography. Invest Ophthalmol Vis Sci. 2003;44:2524-2528.
    • (2003) Invest Ophthalmol Vis Sci , vol.44 , pp. 2524-2528
    • Wang, J.1    Fonn, D.2    Simpson, T.L.3    Jones, L.4
  • 27
    • 0016713124 scopus 로고
    • The instilled fluid dynamics and surface chemistry of polymers in the preocular tear film
    • Benedetto DA, Shah DO, Kaufman HE. The instilled fluid dynamics and surface chemistry of polymers in the preocular tear film. Invest Ophthalmol. 1975;14:887-902.
    • (1975) Invest Ophthalmol , vol.14 , pp. 887-902
    • Benedetto, D.A.1    Shah, D.O.2    Kaufman, H.E.3
  • 29
    • 0000909133 scopus 로고
    • Some physiological aspects of the precorneal tear film
    • Mishima S. Some physiological aspects of the precorneal tear film. Arch Ophthalmol. 1965;73:233-241.
    • (1965) Arch Ophthalmol , vol.73 , pp. 233-241
    • Mishima, S.1
  • 30
    • 0026650519 scopus 로고
    • Study of human precorneal tear film thickness and structure using laser interferometry
    • Prydal JI, Artal P, Woon H, Campbell FW. Study of human precorneal tear film thickness and structure using laser interferometry. Invest Ophthalmol Vis Sci. 1992;33:2006-2011.
    • (1992) Invest Ophthalmol Vis Sci , vol.33 , pp. 2006-2011
    • Prydal, J.I.1    Artal, P.2    Woon, H.3    Campbell, F.W.4
  • 31
    • 0019269754 scopus 로고
    • Micropachometry: A technique for measuring the thickness of the corneal epithelium
    • Wilson G, O'Leary DJ, Henson D. Micropachometry: A technique for measuring the thickness of the corneal epithelium. Invest Ophthalmol Vis Sci. 1980;19:414-417.
    • (1980) Invest Ophthalmol Vis Sci , vol.19 , pp. 414-417
    • Wilson, G.1    O'Leary, D.J.2    Henson, D.3
  • 33
    • 0028051752 scopus 로고
    • Measurement of the human precorneal tear film with a non-contact optical interferometry film thickness measurement system
    • Danjo Y, Nakamura M, Hamano T. Measurement of the human precorneal tear film with a non-contact optical interferometry film thickness measurement system. Jpn J Ophthalmol. 1994;38:260-266.
    • (1994) Jpn J Ophthalmol , vol.38 , pp. 260-266
    • Danjo, Y.1    Nakamura, M.2    Hamano, T.3
  • 34
    • 0031736367 scopus 로고    scopus 로고
    • In vivo tear-film thickness determination and implications for tear-film stability
    • Creech IL, Do LT, Fatt I, Radke CJ. In vivo tear-film thickness determination and implications for tear-film stability. Curr Eye Res. 1998;17:1058-1066.
    • (1998) Curr Eye Res , vol.17 , pp. 1058-1066
    • Creech, I.L.1    Do, L.T.2    Fatt, I.3    Radke, C.J.4
  • 35
    • 84989990661 scopus 로고
    • The conjunctival fluid, its height, volume, density of cells, and flow
    • Norn MS. The conjunctival fluid, its height, volume, density of cells, and flow. Acta Ophthalmol (Copenh). 1966;44: 212-222.
    • (1966) Acta Ophthalmol (Copenh) , vol.44 , pp. 212-222
    • Norn, M.S.1
  • 37
    • 84989990560 scopus 로고
    • On the size of the conjunctival sac
    • Ehlers N. On the size of the conjunctival sac. Acta Ophthalmol (Copenh). 1965;43:205-210.
    • (1965) Acta Ophthalmol (Copenh) , vol.43 , pp. 205-210
    • Ehlers, N.1
  • 38
    • 0014183040 scopus 로고
    • A new division of the conjunctiva on the basis of x-ray examination
    • Kessing SV. A new division of the conjunctiva on the basis of x-ray examination. Acta Ophthalmol (Copenh). 1967;45: 680-683.
    • (1967) Acta Ophthalmol (Copenh) , vol.45 , pp. 680-683
    • Kessing, S.V.1
  • 39
    • 0024385755 scopus 로고
    • An instrument for in vivo tear film interferometry
    • Doane MG. An instrument for in vivo tear film interferometry. Optom Vis Sci. 1989;66:383-388.
    • (1989) Optom Vis Sci , vol.66 , pp. 383-388
    • Doane, M.G.1
  • 40
    • 0030058925 scopus 로고    scopus 로고
    • Lens adherence and postlens tear film changes in closed-eye wear of hydrogel lenses
    • Bruce AS, Mainstone JC. Lens adherence and postlens tear film changes in closed-eye wear of hydrogel lenses. Optom Vis Sci. 1996;73:28-34.
    • (1996) Optom Vis Sci , vol.73 , pp. 28-34
    • Bruce, A.S.1    Mainstone, J.C.2
  • 41
    • 0021932788 scopus 로고
    • Reflectometry of the precorneal film
    • Olsen T. Reflectometry of the precorneal film. Acta Ophthalmol (Copenh). 1985;63:432-438.
    • (1985) Acta Ophthalmol (Copenh) , vol.63 , pp. 432-438
    • Olsen, T.1
  • 42
    • 0346242213 scopus 로고    scopus 로고
    • The tear film - Its role today and in the future
    • Korb DR. Oxford: Butterworth-Heinemann
    • Korb DR. The tear film - its role today and in the future. In: Korb DR. The Tear Film: Structure, Function and Clinical Examination. Oxford: Butterworth-Heinemann; 2002:126-192.
    • (2002) The Tear Film: Structure, Function and Clinical Examination , pp. 126-192
    • Korb, D.R.1
  • 43
    • 0026625727 scopus 로고
    • Study of precorneal tear film thickness and structure by interferometry and confocal microscopy
    • Prydal JI, Campbell FW. Study of precorneal tear film thickness and structure by interferometry and confocal microscopy. Invest Ophthalmol Vis Sci. 1992;33:1996-2005.
    • (1992) Invest Ophthalmol Vis Sci , vol.33 , pp. 1996-2005
    • Prydal, J.I.1    Campbell, F.W.2
  • 44
    • 0027321547 scopus 로고
    • Comparison of tear film thickness in three species determined by the glass fibre method and confocal microscopy
    • Prydal JI, Muir MG, Duly PN. Comparison of tear film thickness in three species determined by the glass fibre method and confocal microscopy. Eye. 1993;7(Pt 3): 472-475.
    • (1993) Eye , vol.7 , Issue.PART 3 , pp. 472-475
    • Prydal, J.I.1    Muir, M.G.2    Duly, P.N.3
  • 46
    • 0031868814 scopus 로고    scopus 로고
    • Mucous contribution to rat tear-film thickness measured with a microelectrode technique
    • Anderton P, Tragoulias S. Mucous contribution to rat tear-film thickness measured with a microelectrode technique. Adv Exp Med Biol. 1998;438:247-252.
    • (1998) Adv Exp Med Biol , vol.438 , pp. 247-252
    • Anderton, P.1    Tragoulias, S.2
  • 48
    • 0001324832 scopus 로고
    • Mucocutaneous junction of lid-margin and distribution of tear fluid
    • Wolff E. Mucocutaneous junction of lid-margin and distribution of tear fluid. Trans Ophthalmol Soc U.K. 1946;66: 291-308.
    • (1946) Trans Ophthalmol Soc U.K. , vol.66 , pp. 291-308
    • Wolff, E.1
  • 49
    • 0002974924 scopus 로고
    • The oily layer of the tear film and evaporation from the corneal surface
    • Mishima S, Maurice DM. The oily layer of the tear film and evaporation from the corneal surface. Exp Eye Res. 1961;1:39-45.
    • (1961) Exp Eye Res , vol.1 , pp. 39-45
    • Mishima, S.1    Maurice, D.M.2
  • 50
    • 0036936646 scopus 로고    scopus 로고
    • Age-related changes in human tear composition and stability
    • Tiffany JM, Gouveia SM. Age-related changes in human tear composition and stability. Adv Exp Med Biol. 2002;506(Pt A):587-591.
    • (2002) Adv Exp Med Biol , vol.506 , Issue.PART A , pp. 587-591
    • Tiffany, J.M.1    Gouveia, S.M.2
  • 51
    • 0014594136 scopus 로고
    • Hydrodynamics of blinking. In vitro study of the interaction of the superficial oily layer and the tears
    • Brown SI, Dervichian DG. Hydrodynamics of blinking. In vitro study of the interaction of the superficial oily layer and the tears. Arch Ophthalmol. 1969;82:541-547.
    • (1969) Arch Ophthalmol , vol.82 , pp. 541-547
    • Brown, S.I.1    Dervichian, D.G.2
  • 52
    • 0018909306 scopus 로고
    • Interactions of eyelids and tears in corneal wetting and the dynamics of the normal human eyeblink
    • Doane MG. Interactions of eyelids and tears in corneal wetting and the dynamics of the normal human eyeblink. Am J Ophthalmol. 1980;89:507-516.
    • (1980) Am J Ophthalmol , vol.89 , pp. 507-516
    • Doane, M.G.1
  • 53
    • 5244305946 scopus 로고
    • The constitution and fundamental properties of solids and liquids. Part II. Liquids
    • Langmuir I. The constitution and fundamental properties of solids and liquids. Part II. Liquids. J Am Chem Soc. 1917;9:1848-1905.
    • (1917) J Am Chem Soc , vol.9 , pp. 1848-1905
    • Langmuir, I.1
  • 54
    • 0031610413 scopus 로고    scopus 로고
    • The meibomian glands and tear film lipids. Structure, function, and control
    • Bron AJ, Tiffany JM. The meibomian glands and tear film lipids. Structure, function, and control. Adv Exp Med Biol. 1998;438:281-295.
    • (1998) Adv Exp Med Biol , vol.438 , pp. 281-295
    • Bron, A.J.1    Tiffany, J.M.2
  • 56
    • 0036354916 scopus 로고    scopus 로고
    • Settling and deformation of a thin elastic shell on a thin fluid layer lying on a solid surface
    • Chauhan A, Radke CJ. Settling and deformation of a thin elastic shell on a thin fluid layer lying on a solid surface. J Colloid Interface Sci. 2002;245:187-197.
    • (2002) J Colloid Interface Sci , vol.245 , pp. 187-197
    • Chauhan, A.1    Radke, C.J.2
  • 57
    • 0014784576 scopus 로고
    • Further studies on the pathophysiology of keratitis sicca of Rollet
    • Brown SI. Further studies on the pathophysiology of keratitis sicca of Rollet. Arch Ophthalmol. 1970;83:542-547.
    • (1970) Arch Ophthalmol , vol.83 , pp. 542-547
    • Brown, S.I.1
  • 58
    • 0021993196 scopus 로고
    • A non-invasive instrument for clinical assessment of the precorneal tear film stability
    • Mengher LS, Bron AJ, Tonge SR, Gilbert DJ. A non-invasive instrument for clinical assessment of the precorneal tear film stability. Curr Eye Res. 1985;4:1-7.
    • (1985) Curr Eye Res , vol.4 , pp. 1-7
    • Mengher, L.S.1    Bron, A.J.2    Tonge, S.R.3    Gilbert, D.J.4
  • 59
    • 0042967746 scopus 로고    scopus 로고
    • Modelling drainage of the precorneal tear film after a blink
    • Braun RJ, Fitt AD. Modelling drainage of the precorneal tear film after a blink. Math Med Biol. 2003;20:1-28.
    • (2003) Math Med Biol , vol.20 , pp. 1-28
    • Braun, R.J.1    Fitt, A.D.2
  • 60
    • 0015877652 scopus 로고
    • Formation and rupture of the tear film
    • Holly FJ. Formation and rupture of the tear film. Exp Eye Res. 1973;15:515-525.
    • (1973) Exp Eye Res , vol.15 , pp. 515-525
    • Holly, F.J.1
  • 61
    • 0021978994 scopus 로고
    • Mechanism of tear film rupture and its implications for contact lens tolerance
    • Sharma A, Ruckenstein E. Mechanism of tear film rupture and its implications for contact lens tolerance. Am J Optom Physiol Opt. 1985;62:246-253.
    • (1985) Am J Optom Physiol Opt , vol.62 , pp. 246-253
    • Sharma, A.1    Ruckenstein, E.2
  • 62
    • 0031867116 scopus 로고    scopus 로고
    • Breakup and dewetting of the corneal mucus layer. An update
    • Sharma A. Breakup and dewetting of the corneal mucus layer. An update. Adv Exp Med Biol. 1998;438:273-280.
    • (1998) Adv Exp Med Biol , vol.438 , pp. 273-280
    • Sharma, A.1
  • 63
    • 0033504306 scopus 로고    scopus 로고
    • Corneal surface regularity and the effect of artificial tears in aqueous tear deficiency
    • Liu Z, Pflugfelder SC. Corneal surface regularity and the effect of artificial tears in aqueous tear deficiency. Ophthalmology. 1999;106:939-943.
    • (1999) Ophthalmology , vol.106 , pp. 939-943
    • Liu, Z.1    Pflugfelder, S.C.2
  • 64
    • 0037983882 scopus 로고    scopus 로고
    • Assessing the severity of keratitis sicca with videokeratoscope indices
    • de Paiva CS, Lindsey JL, Pflugfelder SC. Assessing the severity of keratitis sicca with videokeratoscope indices. Ophthalmology. 2003;110:1102-1109.
    • (2003) Ophthalmology , vol.110 , pp. 1102-1109
    • De Paiva, C.S.1    Lindsey, J.L.2    Pflugfelder, S.C.3
  • 65
    • 0022531113 scopus 로고
    • Non-invasive tear film break-up time: Sensitivity and specificity
    • Mengher LS, Pandher KS, Bron AJ. Non-invasive tear film break-up time: sensitivity and specificity. Acta Ophthalmol (Copenh). 1986;64:441-444.
    • (1986) Acta Ophthalmol (Copenh) , vol.64 , pp. 441-444
    • Mengher, L.S.1    Pandher, K.S.2    Bron, A.J.3
  • 67
    • 0038678932 scopus 로고    scopus 로고
    • Can postlens tear thickness be measured using three-dimensional in vivo confocal microscopy?
    • discussion S115-118, S192-194
    • Petroll WM, Kovoor T, Ladage PM, Cavanagh HD, Jester JV, Robertson DM. Can postlens tear thickness be measured using three-dimensional in vivo confocal microscopy? Eye Contact Lens. 2003;29(1 Suppl): S110-114; discussion S115-118, S192-194.
    • (2003) Eye Contact Lens , vol.29 , Issue.1 SUPPL.
    • Petroll, W.M.1    Kovoor, T.2    Ladage, P.M.3    Cavanagh, H.D.4    Jester, J.V.5    Robertson, D.M.6
  • 68
    • 0037311842 scopus 로고    scopus 로고
    • Differentiation of lipid tear deficiency dry eye by kinetic analysis of tear interference images
    • Goto E, Tseng SC. Differentiation of lipid tear deficiency dry eye by kinetic analysis of tear interference images. Arch Ophthalmol. 2003;121:173-180.
    • (2003) Arch Ophthalmol , vol.121 , pp. 173-180
    • Goto, E.1    Tseng, S.C.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.