메뉴 건너뛰기




Volumn 4, Issue , 2003, Pages 2262-2266

Investigation of position sensitive avalanche photodiodes for a new high resolution PET detector design

Author keywords

[No Author keywords available]

Indexed keywords

DETECTORS; IRRADIATION; OPTICAL RESOLVING POWER; PHOTODIODES; PHOTONS; SCINTILLATION; TUMORS;

EID: 11844280918     PISSN: 10957863     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (8)

References (14)
  • 1
    • 0035428684 scopus 로고    scopus 로고
    • Performance characteristics of micro crystal element (MiCE) detectors
    • Aug.
    • Miyaoka, R.S.; Kohlmyer, S.G.; Lewellen, T.K. Performance characteristics of micro crystal element (MiCE) detectors. IEEE Trans Nucl Sci, vol.48, (no.4, pt.2), Aug. 2001. p. 1403-7.
    • (2001) IEEE Trans Nucl Sci , vol.48 , Issue.4 PART 2 , pp. 1403-1407
    • Miyaoka, R.S.1    Kohlmyer, S.G.2    Lewellen, T.K.3
  • 3
    • 0027998907 scopus 로고
    • High resolution PET imaging and quantitation of pharmaceutical biodistributions in a small animal using APD detectors
    • C.J. Marriott, J.E. Cadorette, R. Lecomte et. al. High Resolution PET Imaging and Quantitation of Pharmaceutical Biodistributions in a Small Animal Using APD Detectors. J Nucl Med 35:1390-7 (1994).
    • (1994) J Nucl Med , vol.35 , pp. 1390-1397
    • Marriott, C.J.1    Cadorette, J.E.2    Lecomte, R.3
  • 4
    • 0029358209 scopus 로고
    • Feasibility study of an avalanche photodiode readout for a high resolution PET with nsec time resolution
    • C. Schmelz, SM Bradbury, I Holl, et al. 1995. Feasibility study of an avalanche photodiode readout for a high resolution PET with nsec time resolution. IEEE Trans. Nucl. Sci. 42:1080-4.
    • (1995) IEEE Trans. Nucl. Sci. , vol.42 , pp. 1080-1084
    • Schmelz, C.1    Bradbury, S.M.2    Holl, I.3
  • 6
    • 0033335619 scopus 로고    scopus 로고
    • A 3D HIDAC-PET Camera with sub-millimetre resolution for imaging small animals
    • June
    • Jeavons, AP, Chandler, RA, Dettmar, CA. A 3D HIDAC-PET Camera with sub-millimetre resolution for imaging small animals. IEEE Trans Nucl Sci Vol 46 (No.3, Pt. 2), June 1999 (468-73).
    • (1999) IEEE Trans Nucl Sci , vol.46 , Issue.3 PT. 2 , pp. 468-473
    • Jeavons, A.P.1    Chandler, R.A.2    Dettmar, C.A.3
  • 8
    • 0036816184 scopus 로고    scopus 로고
    • Anode position and last dynode timing circuits for dual-layer BGO scintillator with PS-PMT based modular PET detectors
    • Oct.
    • Nan Zhang, Thompson CJ, Togane D, Cayouette F, Nguyen KQ. Anode position and last dynode timing circuits for dual-layer BGO scintillator with PS-PMT based modular PET detectors, IEEE Transactions on Nuclear Science, vol.49, no.5, pt.1, Oct. 2002, pp.2203-7.
    • (2002) IEEE Transactions on Nuclear Science , vol.49 , Issue.5 PART 1 , pp. 2203-2207
    • Zhang, N.1    Thompson, C.J.2    Togane, D.3    Cayouette, F.4    Nguyen, K.Q.5
  • 11
    • 0036815754 scopus 로고    scopus 로고
    • Design of a high-resolution and high-sensitivity scintillation crystal array for PET with nearly complete light collection
    • October
    • C.S. Levin. Design of a High-Resolution and High-Sensitivity Scintillation Crystal Array for PET with Nearly Complete Light Collection. IEEE Trans Nucl Sci. Vol. 49, No. 5, October 2002.
    • (2002) IEEE Trans Nucl Sci. , vol.49 , Issue.5
    • Levin, C.S.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.