메뉴 건너뛰기




Volumn 3, Issue , 2002, Pages 1751-1755

Initial Studies of a New Detector Design for Ultra-High Resolution Positron Emission Tomography

Author keywords

[No Author keywords available]

Indexed keywords

AVALANCHE DIODES; CRYSTALS; PHOTODETECTORS; SIGNAL TO NOISE RATIO;

EID: 0142178994     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (4)

References (9)
  • 1
    • 0036815754 scopus 로고    scopus 로고
    • Design of a High Resolution and High Sensitivity Scintillation Crystal Array for PET with Nearly Complete Light Collection
    • Oct.
    • Levin, CS. Design of a High Resolution and High Sensitivity Scintillation Crystal Array for PET with Nearly Complete Light Collection. IEEE Trans Nucl Sci Vol. 49, No.5, Oct. 2002, 2236-43.
    • (2002) IEEE Trans Nucl Sci , vol.49 , Issue.5 , pp. 2236-2243
    • Levin, C.S.1
  • 2
    • 0033059817 scopus 로고    scopus 로고
    • Calculation of positron range and its effect on the fundamental limit of positron emission tomography system spatial resolution
    • Mar.
    • Levin, CS; Hoffman, EJ. Calculation of positron range and its effect on the fundamental limit of positron emission tomography system spatial resolution. Physics in Medicine and Biology, 44 (Mar. 1999) 781-99.
    • (1999) Physics in Medicine and Biology , vol.44 , pp. 781-799
    • Levin, C.S.1    Hoffman, E.J.2
  • 3
    • 0033954080 scopus 로고    scopus 로고
    • Corrigendum for [2], February
    • Corrigendum for [2], Phys. Med. Biol. 45 No 2 (February 2000) 559.
    • (2000) Phys. Med. Biol. , vol.45 , Issue.2 , pp. 559
  • 4
    • 0035428684 scopus 로고    scopus 로고
    • Performance characteristics of micro crystal element (MiCE) detectors
    • Aug.
    • Miyaoka, R.S.; Kohlmyer, S.G.; Lewellen, T.K. Performance characteristics of micro crystal element (MiCE) detectors. IEEE Trans Nucl Sci, vol.48, (no.4, pt.2), Aug. 2001. p.1403-7.
    • (2001) IEEE Trans Nucl Sci , vol.48 , Issue.4 PART. 2 , pp. 1403-1407
    • Miyaoka, R.S.1    Kohlmyer, S.G.2    Lewellen, T.K.3
  • 6
    • 0034594205 scopus 로고    scopus 로고
    • Experimental estimates of the absolute sensitivity of a small animal PET scanner with depth-of-interaction capability
    • 21-57-9
    • Seidel, J.; Vaquero, J.J.; Lee, I.J.; Green, M.V. Experimental estimates of the absolute sensitivity of a small animal PET scanner with depth-of-interaction capability. 2000 IEEE Nuclear Science Symposium Conference Record, (vol.3), p.21/57-9.
    • (2000) 2000 IEEE Nuclear Science Symposium Conference Record , vol.3
    • Seidel, J.1    Vaquero, J.J.2    Lee, I.J.3    Green, M.V.4
  • 7
    • 0034593461 scopus 로고    scopus 로고
    • Large area APDs and monolithic APD arrays
    • October 15-20, Lyon, France. Conference Record. RMD, Inc. Watertown, MA
    • Shah, K.S.; Farrell, R.; Grazioso, R.; Cirignano, L. Large area APDs and monolithic APD arrays. Presented at the 2000 IEEE Nuclear Science Symposium, October 15-20, Lyon, France. Conference Record, vol.1. p.7-22. RMD, Inc. Watertown, MA.
    • (2000) 2000 IEEE Nuclear Science Symposium , vol.1 , pp. 7-22
    • Shah, K.S.1    Farrell, R.2    Grazioso, R.3    Cirignano, L.4
  • 8
    • 0142204960 scopus 로고    scopus 로고
    • Development of compact, low noise and low cost readout electronics for a small PET system based on Avalanche Photodiode Arrays
    • Norfolk, VA Abstract M3-6
    • Habte, F and Levin, CS. Development of compact, low noise and low cost readout electronics for a small PET system based on Avalanche Photodiode Arrays. Presented at the 2002 Medical Imaging Conference, Norfolk, VA Abstract M3-6.
    • (2000) 2002 Medical Imaging Conference
    • Habte, F.1    Levin, C.S.2