Development of a RadFET linear array for intracavitary in vivo dosimetry in external beam radiotherapy and brachytherapy

Author keywords

Dosimetry; In vivo patient dosimetry; MOSFET; RadFET; Radiotherapy; Semiconductor detectors

Indexed keywords

ARRAYS; DOSIMETRY; LINEAR SYSTEMS; MOSFET DEVICES; SEMICONDUCTOR MATERIALS; TISSUE; TUMORS;

EID: 11844263939     PISSN: 10957863     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/nssmic.2003.1352160     Document Type: Conference Paper
Times cited : (3)

References (35)
  • 2
    • 11844274532 scopus 로고    scopus 로고
    • Biological modeling of pelvic radiotherapy: Potential gains from conformal techniques
    • J. Fenwick, "Biological modeling of pelvic radiotherapy: Potential gains from conformal techniques". Med. Phys. 27, No. 5, 1207, 2000.
    • (2000) Med. Phys. , vol.27 , Issue.5 , pp. 1207
    • Fenwick, J.1
  • 3
    • 0003931348 scopus 로고    scopus 로고
    • Physics aspects of quality control in radiotherapy
    • W. P. H. Mayles et al (Editors), "Physics aspects of quality control in radiotherapy", IPEM report No. 81, 1999.
    • (1999) IPEM Report No. 81 , vol.81
    • Mayles, W.P.H.1
  • 4
    • 0001944192 scopus 로고
    • Accuracy requirements and quality assurance of external beam therapy with photons and electrons
    • A. Brahme, J. Chavaudra et al, "Accuracy requirements and quality assurance of external beam therapy with photons and electrons", Acta Oncol. Sup. 1, 1988.
    • (1988) Acta Oncol. Sup. 1
    • Brahme, A.1    Chavaudra, J.2
  • 5
    • 0031844585 scopus 로고    scopus 로고
    • In vivo semiconductor dosimetry as part of routine quality assurance
    • C. J. Millwater, A. S. Macleod et al, "In vivo semiconductor dosimetry as part of routine quality assurance", Br. J. Radial. 71, 661-8, 1998.
    • (1998) Br. J. Radial. , vol.71 , pp. 661-668
    • Millwater, C.J.1    Macleod, A.S.2
  • 6
    • 0021851642 scopus 로고
    • Calculation of the uncertainty in the dose delivered during radiation therapy
    • M. Goitein, "Calculation of the uncertainty in the dose delivered during radiation therapy", Med. Phys. 12, 602-12, 1985.
    • (1985) Med. Phys. , vol.12 , pp. 602-612
    • Goitein, M.1
  • 7
    • 0033556681 scopus 로고    scopus 로고
    • In vivo dosimetry during external photon beam radiotherapy
    • M. Essers and B. J. Mijnheer, "In vivo dosimetry during external photon beam radiotherapy", Int. J. Radiation Oncology Biol. Phys., Vol. 43, No. 2, 245-59, 1999.
    • (1999) Int. J. Radiation Oncology Biol. Phys. , vol.43 , Issue.2 , pp. 245-259
    • Essers, M.1    Mijnheer, B.J.2
  • 8
    • 0032843083 scopus 로고    scopus 로고
    • In vivo dosimetry during conformal radiotherapy, requirements for and findings of a routine procedure
    • J. H. Lanson, M. Essers et al, "In vivo dosimetry during conformal radiotherapy, requirements for and findings of a routine procedure", Radiother. Oncol. 52, 144-51, 1999.
    • (1999) Radiother. Oncol. , vol.52 , pp. 144-151
    • Lanson, J.H.1    Essers, M.2
  • 9
    • 0032850539 scopus 로고    scopus 로고
    • In vivo dosimetry by diode semiconductors in combination with portal films during TBI: Reporting on a 5-year clinical experience
    • P. Mangili, C. Fiorino et al, "In vivo dosimetry by diode semiconductors in combination with portal films during TBI: reporting on a 5-year clinical experience", Radiother. Oncol. 52, 269-76, 1999.
    • (1999) Radiother. Oncol. , vol.52 , pp. 269-276
    • Mangili, P.1    Fiorino, C.2
  • 10
    • 4444221058 scopus 로고    scopus 로고
    • UK Department of Health Publication
    • "Manual of Cancer Standards" UK Department of Health Publication, 2000.
    • (2000) Manual of Cancer Standards
  • 11
    • 11844258133 scopus 로고    scopus 로고
    • Health protection of individuals against the dangers ionising radiations in relation to medical exposures
    • European Communities, L180/22, Council directive 97/43/euratom
    • European Communities, "Health protection of individuals against the dangers ionising radiations in relation to medical exposures". Official Journal European Community. L180/22, Council directive 97/43/euratom, 1997.
    • (1997) Official Journal European Community
  • 12
    • 0028230872 scopus 로고
    • Comprehensive QA for radiation oncology Report 40 of AAPM radiation therapy committee task group 40
    • G. J. Kutcher, L. Coia et al, "Comprehensive QA for radiation oncology Report 40 of AAPM Radiation Therapy Committee Task Group 40", Med. Phys. 21, 581-618, 1994.
    • (1994) Med. Phys. , vol.21 , pp. 581-618
    • Kutcher, G.J.1    Coia, L.2
  • 13
    • 0033744527 scopus 로고    scopus 로고
    • In vivo urethral dose measurements: A method to verify high dose rate prostate treatments
    • I. Brezovich, et al, "In vivo urethral dose measurements: a method to verify high dose rate prostate treatments'", Med. Phys. 27 10, 2297-2302, 2000.
    • (2000) Med. Phys. , vol.27 , Issue.10 , pp. 2297-2302
    • Brezovich, I.1
  • 16
    • 0025166575 scopus 로고
    • Quality assurance in radiotherapy by in vivo dosimetry. 1. Entrance dose measurements, a reliable procedure
    • G. Lunens, J. Van Dam et al, "Quality assurance in radiotherapy by in vivo dosimetry. 1. Entrance dose measurements, a reliable procedure", Radiother. Oncol. 17, 141-51, 1990.
    • (1990) Radiother. Oncol. , vol.17 , pp. 141-151
    • Lunens, G.1    Van Dam, J.2
  • 17
    • 0025110912 scopus 로고
    • Quality assurance in radiotherapy by in vivo dosimetry. 2. Determination of the target absorbed dose
    • G. Lunens, J. Van Dam J et al, "Quality assurance in radiotherapy by in vivo dosimetry. 2. Determination of the target absorbed dose", Radiother. Oncol. 19, 73-87, 1990.
    • (1990) Radiother. Oncol. , vol.19 , pp. 73-87
    • Lunens, G.1    Van Dam, J.J.2
  • 18
    • 0031844585 scopus 로고    scopus 로고
    • In vivo semiconductor dosimetry as part of routine quality assurance
    • C. J.Millwater, A. S.Macleod et al, "In vivo semiconductor dosimetry as part of routine quality assurance", Br. J. Radial. 71, 661-8, 1998.
    • (1998) Br. J. Radial. , vol.71 , pp. 661-668
    • Millwater, C.J.1    Macleod, A.S.2
  • 19
    • 0030973601 scopus 로고    scopus 로고
    • An audit of radiotherapy patient doses measured with in vivo semiconductor detectors
    • A. Adeyami and J. Lord, "An audit of radiotherapy patient doses measured with in vivo semiconductor detectors", BJR 70, 339-408, 1997.
    • (1997) BJR , vol.70 , pp. 339-408
    • Adeyami, A.1    Lord, J.2
  • 20
    • 0027976309 scopus 로고
    • Importance of in vivo dosimetry as part of a quality assurance program in tangential breast treatments
    • G. Leunens, J. Van Dam et al, "Importance of in vivo dosimetry as part of a quality assurance program in tangential breast treatments", Int. J. Rod. Oncol. Biol. Phys. 28, 285-96, 1994.
    • (1994) Int. J. Rod. Oncol. Biol. Phys. , vol.28 , pp. 285-296
    • Leunens, G.1    Van Dam, J.2
  • 21
    • 0026319448 scopus 로고
    • In vivo dosimetry for tangential breast irradiation: Role of the equipment in the accuracy of dose delivery
    • G. Leunens, J. Verstraete et al, "In vivo dosimetry for tangential breast irradiation: role of the equipment in the accuracy of dose delivery", Radiother. Oncol, 22, 285-89, 1991.
    • (1991) Radiother. Oncol , vol.22 , pp. 285-289
    • Leunens, G.1    Verstraete, J.2
  • 22
    • 0027994644 scopus 로고
    • Patient dosimetry quality assurance program with a commercial diode system
    • P. C. Lee, J. M Sawicka and G. P. Glasgow, "Patient dosimetry quality assurance program with a commercial diode system", Int. J. Radiation Oncology Biol. Phys. 29, 5, 1175-82, 1994.
    • (1994) Int. J. Radiation Oncology Biol. Phys. , vol.29 , Issue.5 , pp. 1175-1182
    • Lee, P.C.1    Sawicka, J.M.2    Glasgow, G.P.3
  • 23
    • 0035313818 scopus 로고    scopus 로고
    • Assessment of target dose delivery in anal cancer using in vivo thermoluminescent dosimetry
    • D. C. Weber, P. Nouet et al "Assessment of target dose delivery in anal cancer using in vivo thermoluminescent dosimetry", Radiotherapy and Oncology 59, 39-43, 2001.
    • (2001) Radiotherapy and Oncology , vol.59 , pp. 39-43
    • Weber, D.C.1    Nouet, P.2
  • 24
    • 4444328905 scopus 로고    scopus 로고
    • Characterisation of radiation of radiation response of 400nm implanted gate oxide RadFET
    • A. Jaksic, G. Ristic et al, "Characterisation of radiation of radiation response of 400nm implanted gate oxide RadFET", Met. Sci. Eng. B-Solid, 89 1-3, 2002.
    • (2002) Met. Sci. Eng. B-Solid , vol.89 , pp. 1-3
    • Jaksic, A.1    Ristic, G.2
  • 25
    • 11844293321 scopus 로고    scopus 로고
    • Optimised stacked RadFETs for milli-rad dose measurements
    • Fontevarad, France Sept.
    • B. O'Connell, C. Mcarthy et al, "Optimised stacked RadFETs for milli-rad dose measurements", RADECs 99, Fontevarad, France Sept. 99.
    • (1999) RADECs 99
    • O'Connell, B.1    Mcarthy, C.2
  • 26
    • 84920732031 scopus 로고    scopus 로고
    • Review Paper: RaFETs for improved radiation sensitivity
    • Bologna
    • B. O'connell, W. Kelleher et al, "Review Paper: RaFETs for improved radiation sensitivity" ESSDERC 96, Bologna,
    • ESSDERC 96
    • O'Connell, B.1    Kelleher, W.2
  • 27
    • 0030028462 scopus 로고    scopus 로고
    • A new radiotherapy surface dose detector: The MOSFET
    • M. J. Butson, J. N. Rozenfeld et al, "A new radiotherapy surface dose detector: The MOSFET" Med. Phys. 23 655-58, 1996.
    • (1996) Med. Phys. , vol.23 , pp. 655-658
    • Butson, M.J.1    Rozenfeld, J.N.2
  • 28
    • 0028213977 scopus 로고
    • Evaluation of a dual bias dual metal oxide-silicon semiconductor field effect transistor as a radiation dosimeter
    • M. Soubra, J. Cygler and G. Mackay, "Evaluation of a dual bias dual metal oxide-silicon semiconductor field effect transistor as a radiation dosimeter", Med. Phys. 21, 567-72, 1994.
    • (1994) Med. Phys. , vol.21 , pp. 567-572
    • Soubra, M.1    Cygler, J.2    Mackay, G.3
  • 30
    • 0022904335 scopus 로고
    • RADFETs: A review of the use of metal-oxide-silicon devices as integrating dosimeters
    • A. Homes-Sieldle and L. Adams, "RADFETs: a review of the use of metal-oxide-silicon devices as integrating dosimeters", Radiat. Phys. Chem. 28, 235-44, 1986.
    • (1986) Radiat. Phys. Chem. , vol.28 , pp. 235-244
    • Homes-Sieldle, A.1    Adams, L.2
  • 31
    • 0031441616 scopus 로고    scopus 로고
    • The response of a MOSFET, p-type semiconductor and LiF TLD to quasimonoenergetic x-rays
    • C. R. Edwards, S. Green, et al, "The response of a MOSFET, p-type semiconductor and LiF TLD to quasimonoenergetic x-rays", Phys. Med. Biol. 42, 2383-91, 1997.
    • (1997) Phys. Med. Biol. , vol.42 , pp. 2383-2391
    • Edwards, C.R.1    Green, S.2
  • 32
    • 0030212322 scopus 로고    scopus 로고
    • Anisotropically conductive adhesive Flip-Chip bonding on rigid and flexible printed circuit substrates
    • Z. Lai and J. Liu, "Anisotropically conductive adhesive Flip-Chip bonding on rigid and flexible printed circuit substrates", IEEE Trans. On Components, Packaging and Manufacturing Technol. PartB. 19, 3 1996.
    • (1996) IEEE Trans. on Components, Packaging and Manufacturing Technol. PartB , vol.19 , pp. 3
    • Lai, Z.1    Liu, J.2
  • 33
    • 0344165061 scopus 로고
    • Characterisation and reliability study of anisotropic conductive adhesives for fine-pitch package assembly
    • F. Stam, P. O'Grady and J. Barrett, "Characterisation and reliability study of anisotropic conductive adhesives for fine-pitch package assembly", J. of Electronics Manufacturing, 5, 1, 95.
    • (1995) J. of Electronics Manufacturing , vol.5 , pp. 1
    • Stam, F.1    O'Grady, P.2    Barrett, J.3
  • 34
    • 11844280224 scopus 로고    scopus 로고
    • Novel developments in the MOSFET dosimeter for neutron dosimetry applications
    • submitted, October
    • R. A. Price, C. Benson, et al, "Novel developments in the MOSFET dosimeter for neutron dosimetry applications", submitted, Rad Proc Dosim. October 2003
    • (2003) Rad Proc Dosim.
    • Price, R.A.1    Benson, C.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.