Volumn 70, Issue APR., 1997, Pages 399-408

An audit of radiotherapy patient doses measured with in vivo semiconductor detectors

Author keywords

[No Author keywords available]

Indexed keywords

ABDOMEN; ARTICLE; BREAST; DOSIMETRY; ERROR; HEAD AND NECK CANCER; HUMAN; MAJOR CLINICAL STUDY; MEDICAL AUDIT; PELVIS; RADIATION DOSE; RADIOTHERAPY; SEMICONDUCTOR; THORAX;

EID: 0030973601     PISSN: 00071285     EISSN: None     Source Type: Journal    
DOI: 10.1259/bjr.70.832.9166077     Document Type: Article
Times cited : (24)

References (10)
  • 3
    • 0025166575 scopus 로고
    • Quality assurance in radiotherapy by in vivo dosimetry. 1. Entrance dose measurements, a reliable procedure
    • Leunens G, Van Dam J, Dutreix A, van der Schueren E. Quality assurance in radiotherapy by in vivo dosimetry. 1. Entrance dose measurements, a reliable procedure. Radiother Oncol 1990; 17:141-151.
    • (1990) Radiother Oncol , vol.17 , pp. 141-151
    • Leunens, G.1    Van Dam, J.2    Dutreix, A.3    Van Der Schueren, E.4
  • 4
    • 0023870307 scopus 로고
    • Characteristics of silicon diodes as patient dosemeters in external beam therapy
    • Nilsson B, Ruden BI, Sorcini B. Characteristics of silicon diodes as patient dosemeters in external beam therapy. Radiother Oncol 1988;11:279-88.
    • (1988) Radiother Oncol , vol.11 , pp. 279-288
    • Nilsson, B.1    Ruden, B.I.2    Sorcini, B.3
  • 5
    • 0023622870 scopus 로고
    • General specifications for silicon semiconductors for use in radiotherapy dosimetry
    • Rikner G, Grusell E. General specifications for silicon semiconductors for use in radiotherapy dosimetry. Phys Med Biol 1987;32:1109-17.
    • (1987) Phys Med Biol , vol.32 , pp. 1109-1117
    • Rikner, G.1    Grusell, E.2
  • 6
    • 0025110912 scopus 로고
    • Quality assurance in radiotherapy by in vivo dosimetry. 2. Determination of the target absorbed dose
    • Leunens G, Van Dam J, Dutreix A, van der Schueren E. Quality assurance in radiotherapy by in vivo dosimetry. 2. Determination of the target absorbed dose. Radiother Oncol 1990;19:73-87.
    • (1990) Radiother Oncol , vol.19 , pp. 73-87
    • Leunens, G.1    Van Dam, J.2    Dutreix, A.3    Van Der Schueren, E.4
  • 7
    • 0027994644 scopus 로고
    • Patient dosimetry quality assurance program with a commercial diode system
    • Lee PC, Sawicka JM, Glasgow GP. Patient dosimetry quality assurance program with a commercial diode system. Int J Radiat Oncol Biol Phys 1994;29:1175-82.
    • (1994) Int J Radiat Oncol Biol Phys , vol.29 , pp. 1175-1182
    • Lee, P.C.1    Sawicka, J.M.2    Glasgow, G.P.3
  • 8
    • 0022538071 scopus 로고
    • Evaluation of temperature effects in p-type silicon detectors
    • Grusell E, Rikner G. Evaluation of temperature effects in p-type silicon detectors. Phys Med Biol 1986;31:527-34.
    • (1986) Phys Med Biol , vol.31 , pp. 527-534
    • Grusell, E.1    Rikner, G.2
  • 9
    • 0025183565 scopus 로고
    • Code of Practice for high-energy photon therapy dosimetry based on the NPL absorbed dose calibration service
    • Institute of Physical Science in Medicine. Code of Practice for high-energy photon therapy dosimetry based on the NPL absorbed dose calibration service. Phys Med Biol 1990;35:1355-60.
    • (1990) Phys Med Biol , vol.35 , pp. 1355-1360
  • 10
    • 0028958815 scopus 로고
    • Detection of errors in individual patients in radiotherapy by systematic in vivo dosimetry
    • Noel A, Aletti P, Bey P, Malissard L. Detection of errors in individual patients in radiotherapy by systematic in vivo dosimetry. Radiother Oncol 1995;34:144-51.
    • (1995) Radiother Oncol , vol.34 , pp. 144-151
    • Noel, A.1    Aletti, P.2    Bey, P.3    Malissard, L.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.