메뉴 건너뛰기




Volumn 26 IV, Issue , 2004, Pages 2568-2570

Biological sensing with an on-chip resistive pulse analyzer

Author keywords

Antibody antigen binding; Coulter counting; Resistive pulse sensors; Single molecule sensitivity

Indexed keywords

ANTIBODIES; DEPOSITION; DNA; ELECTRON BEAMS; ETCHING; ION BEAMS; LITHOGRAPHY; MOLECULAR BIOLOGY;

EID: 11144352836     PISSN: 05891019     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (3)

References (11)
  • 2
    • 0028465092 scopus 로고
    • Counting polymers moving through a single ion channel
    • S. M. Bezrukov, I. Vodyanoy, and V. A. Parsegian, "Counting polymers moving through a single ion channel," Nature, vol. 370, no. 6487, pp. 279-281, 1994.
    • (1994) Nature , vol.370 , Issue.6487 , pp. 279-281
    • Bezrukov, S.M.1    Vodyanoy, I.2    Parsegian, V.A.3
  • 3
    • 0035855827 scopus 로고    scopus 로고
    • Stochastic sensors inspired by biology
    • H. Bayley and P. S. Cremer, "Stochastic sensors inspired by biology," Nature, vol. 413, no. 6852, pp. 226-230, 2001.
    • (2001) Nature , vol.413 , Issue.6852 , pp. 226-230
    • Bayley, H.1    Cremer, P.S.2
  • 4
    • 0031194564 scopus 로고    scopus 로고
    • Designed protein pores as components for biosensors
    • O. Braha et al., "Designed protein pores as components for biosensors," Chemical Biology, vol. 4, no. 7, pp. 497-505, 1997.
    • (1997) Chemical Biology , vol.4 , Issue.7 , pp. 497-505
    • Braha, O.1
  • 5
    • 0035849885 scopus 로고    scopus 로고
    • Ion-beam sculpting at nanometer length scales
    • J. Li et al., "Ion-beam sculpting at nanometer length scales," Nature, vol. 412, no. 6843, pp. 166-169, 2001.
    • (2001) Nature , vol.412 , Issue.6843 , pp. 166-169
    • Li, J.1
  • 6
    • 0034645593 scopus 로고    scopus 로고
    • Single carbon nanotube membranes: A well-defined model for studying mass transport through nanoporous materials
    • L. Sun and R. M. Crooks, "Single carbon nanotube membranes: A well-defined model for studying mass transport through nanoporous materials," Journal of the American Chemical Society, vol. 122, no. 49, pp. 12340-12345, 2000.
    • (2000) Journal of the American Chemical Society , vol.122 , Issue.49 , pp. 12340-12345
    • Sun, L.1    Crooks, R.M.2
  • 7
    • 0035669486 scopus 로고    scopus 로고
    • Quantitative sensing of nanoscale colloids using a microchip Coulter counter
    • O. A. Saleh and L. L. Sohn, "Quantitative sensing of nanoscale colloids using a microchip Coulter counter," Review of Scientific Instruments, vol. 72, no. 12, pp. 4449-4451, 2001.
    • (2001) Review of Scientific Instruments , vol.72 , Issue.12 , pp. 4449-4451
    • Saleh, O.A.1    Sohn, L.L.2
  • 8
    • 0036936872 scopus 로고    scopus 로고
    • Correcting off-axis effects in an on-chip resistive-pulse analyzer
    • O. A. Saleh and L. L. Sohn, "Correcting off-axis effects in an on-chip resistive-pulse analyzer," Review of Scientific Instruments, vol. 73, no. 12, pp. 4396-4398, 2002.
    • (2002) Review of Scientific Instruments , vol.73 , Issue.12 , pp. 4396-4398
    • Saleh, O.A.1    Sohn, L.L.2
  • 9
    • 0038632924 scopus 로고    scopus 로고
    • An artificial nanopore for molecular sensing
    • O. A. Saleh and L. L. Sohn, "An artificial nanopore for molecular sensing," Nano Letters, vol. 3, no. 1, pp. 37-38, 2003.
    • (2003) Nano Letters , vol.3 , Issue.1 , pp. 37-38
    • Saleh, O.A.1    Sohn, L.L.2
  • 11
    • 0014813247 scopus 로고
    • Counting and sizing submicron particles by the resistive pulse technique
    • R. W. Deblois and C. P. Bean, "Counting and sizing submicron particles by the resistive pulse technique," Review of Scientific Instruments, vol. 41, no. 7, pp. 909-913, 1970.
    • (1970) Review of Scientific Instruments , vol.41 , Issue.7 , pp. 909-913
    • Deblois, R.W.1    Bean, C.P.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.