메뉴 건너뛰기




Volumn 26 II, Issue , 2004, Pages 1287-1289

Conductivity images of biological tissue phantoms using a 3.0 tesla MREIT system

Author keywords

Conductivity image; MREIT; Tissue phantom

Indexed keywords

ALGORITHMS; BIOLOGICAL ORGANS; ELECTRODES; ELECTROENCEPHALOGRAPHY; HARMONIC ANALYSIS; MAGNETIC FLUX; MAGNETIC RESONANCE IMAGING; MAGNETOENCEPHALOGRAPHY; SIGNAL TO NOISE RATIO; TISSUE;

EID: 11144300795     PISSN: 05891019     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (9)

References (11)
  • 2
    • 0035007151 scopus 로고    scopus 로고
    • Functional MRI with simultaneous EEG recording: Feasibility and application to motor and visual activation
    • F. Lazeyras, I. Zimine, O. Blanke, S. H. Perrig, and M. Seeck, "Functional MRI with simultaneous EEG recording: feasibility and application to motor and visual activation," J. Magn. Reson. Imag., vol. 13, pp. 943-948, 2001.
    • (2001) J. Magn. Reson. Imag. , vol.13 , pp. 943-948
    • Lazeyras, F.1    Zimine, I.2    Blanke, O.3    Perrig, S.H.4    Seeck, M.5
  • 3
    • 0028731158 scopus 로고
    • Impedance tomography using internal current density distribution measured by nuclear magnetic resonance
    • E. J. Woo, S. Y. Lee, and C. W. Mun, "Impedance tomography using internal current density distribution measured by nuclear magnetic resonance," Proc. SPIE Ann. Conf., pp. 377-385, 1994.
    • (1994) Proc. SPIE Ann. Conf. , pp. 377-385
    • Woo, E.J.1    Lee, S.Y.2    Mun, C.W.3
  • 4
    • 0036157954 scopus 로고    scopus 로고
    • Magnetic resonance electrical impedance tomography (MREIT): Simulation study of J-substitution algorithm
    • O. Kwon, E. J. Woo, J. R. Yoon, and J. K. Seo, "Magnetic resonance electrical impedance tomography (MREIT): simulation study of J-substitution algorithm," IEEE Trans. Biomed. Eng., vol. 48, pp. 160-167, 2002.
    • (2002) IEEE Trans. Biomed. Eng. , vol.48 , pp. 160-167
    • Kwon, O.1    Woo, E.J.2    Yoon, J.R.3    Seo, J.K.4
  • 5
    • 0036591488 scopus 로고    scopus 로고
    • J-substitution algorithm in magnetic resonance electrical impedance tomography (MREIT): Phantom experiments for static resistivity images
    • H. S. Khang, B. I. Lee, S. H. Oh, E. J. Woo, S. Y. Lee, M. H. Cho, O. Kwon, J. R. Yoon, and J. K. Seo, "J-substitution algorithm in magnetic resonance electrical impedance tomography (MREIT): phantom experiments for static resistivity images," IEEE Trans. Med. Imag., vol. 21, pp. 695-702, 2002.
    • (2002) IEEE Trans. Med. Imag. , vol.21 , pp. 695-702
    • Khang, H.S.1    Lee, B.I.2    Oh, S.H.3    Woo, E.J.4    Lee, S.Y.5    Cho, M.H.6    Kwon, O.7    Yoon, J.R.8    Seo, J.K.9
  • 6
    • 0038445928 scopus 로고    scopus 로고
    • Three-dimensional forward solver and its performance analysis in magnetic resonance electrical impedance tomography (MREIT) using recessed electrodes
    • B. I. Lee, S. H. Oh, E. J. Woo, S. Y. Lee, M. H. Cho, O. Kwon, J., K. Seo, J. Y. Lee, and W. S. Baek, "Three-dimensional forward solver and its performance analysis in magnetic resonance electrical impedance tomography (MREIT) using recessed electrodes," Phys. Med. Biol., vol. 48, pp. 1971-1986, 2003.
    • (2003) Phys. Med. Biol. , vol.48 , pp. 1971-1986
    • Lee, B.I.1    Oh, S.H.2    Woo, E.J.3    Lee, S.Y.4    Cho, M.H.5    Kwon, O.6    Seo, J.K.7    Lee, J.Y.8    Baek, W.S.9
  • 7
    • 0038644775 scopus 로고    scopus 로고
    • Reconstruction of conductivity and current density images using only one component of magnetic field measurements
    • J. K. Seo, J. R. Yoon, E. J. Woo, and O. Kwon, "Reconstruction of conductivity and current density images using only one component of magnetic field measurements," IEEE Trans. Biomed. Eng., vol. 50, pp. 1121-1124, 2003.
    • (2003) IEEE Trans. Biomed. Eng. , vol.50 , pp. 1121-1124
    • Seo, J.K.1    Yoon, J.R.2    Woo, E.J.3    Kwon, O.4
  • 10
    • 1642362448 scopus 로고    scopus 로고
    • z decomposition algorithm in magnetic resonance electrical impedance tomography (MREIT)
    • z decomposition algorithm in magnetic resonance electrical impedance tomography (MREIT)," IEEE Trans. Med. Imag., vol. 23, pp. 388-394, 2004.
    • (2004) IEEE Trans. Med. Imag. , vol.23 , pp. 388-394
    • Park, C.1    Kwon, O.2    Woo, E.J.3    Seo, J.K.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.