메뉴 건너뛰기




Volumn 7, Issue 5, 2004, Pages 274-277

Initial experience of an automated anastomotic distal device in off-pump CABG

Author keywords

[No Author keywords available]

Indexed keywords

NITINOL;

EID: 10944270738     PISSN: 10983511     EISSN: None     Source Type: Journal    
DOI: 10.1532/HSF98.20041060     Document Type: Article
Times cited : (5)

References (13)
  • 1
    • 0142155058 scopus 로고    scopus 로고
    • An automatic sutureless coronary anastomotic device: Initial results of an animal study
    • Bar-El Y, Tio FO, Shofti R. 2003. An automatic sutureless coronary anastomotic device: initial results of an animal study. Heart Surg Forum 6:369-74.
    • (2003) Heart Surg. Forum , vol.6 , pp. 369-374
    • Bar-El, Y.1    Tio, F.O.2    Shofti, R.3
  • 2
    • 0024396914 scopus 로고
    • Sutureless microvascular anastomosis using the THC: YAG laser: A primarily report
    • Bass LS, Treat MR, Dzakonski C, et al. 1989. Sutureless microvascular anastomosis using the THC: YAG laser: a primarily report. Microsurgery 10:189-93.
    • (1989) Microsurgery , vol.10 , pp. 189-193
    • Bass, L.S.1    Treat, M.R.2    Dzakonski, C.3
  • 3
    • 0032741679 scopus 로고    scopus 로고
    • Favorable aspect of stapled anastomosis: An endothelial function study
    • Chavanon O, Perrault LP. 1999. Favorable aspect of stapled anastomosis: an endothelial function study. Ann Thorac Surg 68:1443-4.
    • (1999) Ann. Thorac. Surg. , vol.68 , pp. 1443-1444
    • Chavanon, O.1    Perrault, L.P.2
  • 4
    • 0037167654 scopus 로고    scopus 로고
    • First clinical results with a new mechanical connector for distal coronary artery anastomoses in CABG
    • Eckstein FS, Bonilla LF, Englberger L, et al. 2002. First clinical results with a new mechanical connector for distal coronary artery anastomoses in CABG. Circulation 106:I1-4.
    • (2002) Circulation , vol.106
    • Eckstein, F.S.1    Bonilla, L.F.2    Englberger, L.3
  • 5
    • 0034843180 scopus 로고    scopus 로고
    • Ventriculocoronary artery bypass results using a mesh-tipped device in a porcine model
    • Emery RW, Eales F, Van Meter CH Jr, et al. 2001. Ventriculocoronary artery bypass results using a mesh-tipped device in a porcine model. Ann Thorac Surg 72:S1004-8.
    • (2001) Ann. Thorac. Surg. , vol.72
    • Emery, R.W.1    Eales, F.2    Van Meter Jr., C.H.3
  • 6
    • 10744226940 scopus 로고    scopus 로고
    • Automated distal coronary bypass with a novel magnetic coupler (MVP system)
    • Filsoufi F, Farivar RS, Aklog L, et al. 2004. Automated distal coronary bypass with a novel magnetic coupler (MVP system). J Thorac Cardiovasc Surg 127:185-92.
    • (2004) J. Thorac. Cardiovasc. Surg. , vol.127 , pp. 185-192
    • Filsoufi, F.1    Farivar, R.S.2    Aklog, L.3
  • 7
    • 0033858145 scopus 로고    scopus 로고
    • Sutureless coronary artery bypass with biologic glued anastomoses: Preliminary in vivo and in vitro results
    • Gundry SR, Black K, Izutani H. 2000. Sutureless coronary artery bypass with biologic glued anastomoses: preliminary in vivo and in vitro results. J Thorac Cardiovasc Surg 120:473-7.
    • (2000) J. Thorac. Cardiovasc. Surg. , vol.120 , pp. 473-477
    • Gundry, S.R.1    Black, K.2    Izutani, H.3
  • 8
    • 0036799143 scopus 로고    scopus 로고
    • Bilateral skeletonized internal thoracic artery graftings in off-pump coronary artery bypass: Early result of Y versus in situ grafts
    • Kim K-B, Cho KR, Chang W-I, Lim C, Ham BM, Kim YL. 2002. Bilateral skeletonized internal thoracic artery graftings in off-pump coronary artery bypass: early result of Y versus in situ grafts. Ann Thorac Surg 74:S1371-7.
    • (2002) Ann. Thorac. Surg. , vol.74
    • Kim, K.-B.1    Cho, K.R.2    Chang, W.-I.3    Lim, C.4    Ham, B.M.5    Kim, Y.L.6
  • 9
    • 0032168412 scopus 로고    scopus 로고
    • Facilitated vascular anastomoses: The one-shot device
    • Nataf P, Hinchliffe P, Manzo S, et al. 1998. Facilitated vascular anastomoses: the one-shot device. Ann Thorac Surg. 66:1041-4.
    • (1998) Ann. Thorac. Surg. , vol.66 , pp. 1041-1044
    • Nataf, P.1    Hinchliffe, P.2    Manzo, S.3
  • 10
    • 0036189143 scopus 로고    scopus 로고
    • An experimental model of saphenous vein-to-coronary artery anastomosis with the St. Jude medical stainless steel connector
    • Schaff HV, Zehr KJ, Bonilla LF, et al. 2002. An experimental model of saphenous vein-to-coronary artery anastomosis with the St. Jude medical stainless steel connector. Ann Thorac Surg 73:830-6.
    • (2002) Ann. Thorac. Surg. , vol.73 , pp. 830-836
    • Schaff, H.V.1    Zehr, K.J.2    Bonilla, L.F.3
  • 11
    • 0033931588 scopus 로고    scopus 로고
    • Assessment of patented coronary end-to-side anastomotic devices using micromechanical bonding
    • Scheltes JS, Heikens M, Pistecky PV, et al. 2000. Assessment of patented coronary end-to-side anastomotic devices using micromechanical bonding. Ann Thorac Surg 70:218-22.
    • (2000) Ann. Thorac. Surg. , vol.70 , pp. 218-222
    • Scheltes, J.S.1    Heikens, M.2    Pistecky, P.V.3
  • 12
    • 0034163018 scopus 로고    scopus 로고
    • Evaluation of a new device for quick sutureless coronary artery anastomosis in surviving sheep
    • Solem JO, Boumzebra D, Al-Buraiki J, et al. 2000. Evaluation of a new device for quick sutureless coronary artery anastomosis in surviving sheep. Eur J Cardiothoracic Surg 17:1046-8.
    • (2000) Eur. J. Cardiothoracic. Surg. , vol.17 , pp. 1046-1048
    • Solem, J.O.1    Boumzebra, D.2    Al-Buraiki, J.3
  • 13
    • 0038386453 scopus 로고    scopus 로고
    • Evaluation of a novel 2 mm internal diameter stainless steel saphenous vein to coronary artery connector: Laboratory studies of on-pump and off-pump revascularization
    • Zehr KJ, Hamner CE, Bonilla LF, et al. 2003. Evaluation of a novel 2 mm internal diameter stainless steel saphenous vein to coronary artery connector: laboratory studies of on-pump and off-pump revascularization. Eur J Cardiothorac Surg 23:925-34.
    • (2003) Eur. J. Cardiothorac. Surg. , vol.23 , pp. 925-934
    • Zehr, K.J.1    Hamner, C.E.2    Bonilla, L.F.3