Volumn 58, Issue 5, 2003, Pages 777-784

In vivo evaluation of a new bioabsorbable self-expanding biliary stent

Author keywords

[No Author keywords available]

Indexed keywords

BILIRUBIN;

EID: 10744227673     PISSN: 00165107     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0016-5107(03)02016-9     Document Type: Article
Times cited : (80)

References (19)
  • 1
    • 19044364871 scopus 로고    scopus 로고
    • "Tannenbaum" teflon stents versus traditional polyethylene stents for treatment of malignant biliary stricture
    • Catalano MF, Geenen JE, Lehman GA, Seigal J, Jacob L, Schmalz MJ, et al. "Tannenbaum" teflon stents versus traditional polyethylene stents for treatment of malignant biliary stricture. Gastrointest Endosc 2002;55:354-8.
    • (2002) Gastrointest Endosc , vol.55 , pp. 354-358
    • Catalano, M.F.1    Geenen, J.E.2    Lehman, G.A.3    Seigal, J.4    Jacob, L.5    Schmalz, M.J.6
  • 2
    • 0026489489 scopus 로고
    • Randomised trial of self-expanding metal stents versus polyethylene stents for distal malignant biliary obstructions
    • Davis PH, Groen AK, Rauws EA, Tytgat GN, Huibregtse K. Randomised trial of self-expanding metal stents versus polyethylene stents for distal malignant biliary obstructions. Lancet 1992;340:1488-92.
    • (1992) Lancet , vol.340 , pp. 1488-1492
    • Davis, P.H.1    Groen, A.K.2    Rauws, E.A.3    Tytgat, G.N.4    Huibregtse, K.5
  • 3
    • 0027161730 scopus 로고
    • A prospective, randomized, controlled trial of metal stents for malignant obstruction of the common bile duct
    • Knyrim K, Wagner HJ, Pausch J, Vakil N. A prospective, randomized, controlled trial of metal stents for malignant obstruction of the common bile duct. Endoscopy 1993;25:207-12.
    • (1993) Endoscopy , vol.25 , pp. 207-212
    • Knyrim, K.1    Wagner, H.J.2    Pausch, J.3    Vakil, N.4
  • 4
    • 0029929933 scopus 로고    scopus 로고
    • Human tissue responses to metal stents implanted in vivo for the palliation of malignant stenosis
    • Bethge N, Sommer A, Gross U, von Kleist D, Vakil N. Human tissue responses to metal stents implanted in vivo for the palliation of malignant stenosis. Gastrointest Endosc 1996;43:596-602.
    • (1996) Gastrointest Endosc , vol.43 , pp. 596-602
    • Bethge, N.1    Sommer, A.2    Gross, U.3    Von Kleist, D.4    Vakil, N.5
  • 6
    • 0032927619 scopus 로고    scopus 로고
    • Materials properties of absorbable self-reinforced fibrillated poly-96L/ 4 D-lactide (SR-PLA96) rods: A study in vitro and in vivo
    • Saikku-Backstrom A, Tulamo RM, Pohonen T, Törmälä P, Räihä JE, Rokkanen P. Materials properties of absorbable self-reinforced fibrillated poly-96L/4 D-lactide (SR-PLA96) rods: a study in vitro and in vivo. J Mater Sci Mater Med 1999;10:1-8.
    • (1999) J Mater Sci Mater Med , vol.10 , pp. 1-8
    • Saikku-Backstrom, A.1    Tulamo, R.M.2    Pohonen, T.3    Törmälä, P.4    Räihä, J.E.5    Rokkanen, P.6
  • 7
    • 0000580235 scopus 로고    scopus 로고
    • Bioabsorbable stents for gastrointestinal endoscopy
    • Freeman ML. Bioabsorbable stents for gastrointestinal endoscopy. Techniques in Gastrointest Endosc 2001;3:120-5.
    • (2001) Techniques in Gastrointest Endosc , vol.3 , pp. 120-125
    • Freeman, M.L.1
  • 8
    • 0023129625 scopus 로고
    • Characterization of the content of occluded biliary endoprostheses
    • Groen AK, Out T, Huibregtes K. Characterization of the content of occluded biliary endoprostheses. Endoscopy 1987;19:57-9.
    • (1987) Endoscopy , vol.19 , pp. 57-59
    • Groen, A.K.1    Out, T.2    Huibregtes, K.3
  • 12
    • 0242489816 scopus 로고    scopus 로고
    • Expandable metal stents: Physical properties and tissue responses
    • Nelson DB. Expandable metal stents: physical properties and tissue responses. Techniques in Gastrointest Endosc 2001;3(2):70-4.
    • (2001) Techniques in Gastrointest Endosc , vol.3 , Issue.2 , pp. 70-74
    • Nelson, D.B.1
  • 14
    • 0034580276 scopus 로고    scopus 로고
    • Synthetic biodegradable polymers as orthopedic devices
    • Middleton JC, Tipton AJ. Synthetic biodegradable polymers as orthopedic devices. Biomaterials 2000;21:2335-46.
    • (2000) Biomaterials , vol.21 , pp. 2335-2346
    • Middleton, J.C.1    Tipton, A.J.2
  • 15
    • 0031614747 scopus 로고    scopus 로고
    • Bioabsorbable polymers: Materials technology and surgical applications
    • Törmälä P, Pohjonen T, Rokkanen P. Bioabsorbable polymers: materials technology and surgical applications. Proc Inst Mech Eng [H] 1998;212:101-11.
    • (1998) Proc Inst Mech Eng [H] , vol.212 , pp. 101-111
    • Törmälä, P.1    Pohjonen, T.2    Rokkanen, P.3
  • 17
    • 0007488634 scopus 로고    scopus 로고
    • Initial and 6 month results of biodegradable poly-l-lactic acid coronary stents in humans
    • Tamai H, Igaki K, Kyo E, Kosuga K, Kawashima A, Matsui S, et al. Initial and 6 month results of biodegradable poly-l-lactic acid coronary stents in humans. Circulation 2000;102:399-404.
    • (2000) Circulation , vol.102 , pp. 399-404
    • Tamai, H.1    Igaki, K.2    Kyo, E.3    Kosuga, K.4    Kawashima, A.5    Matsui, S.6
  • 19
    • 0035940374 scopus 로고    scopus 로고
    • Sustained suppression of neointimal proliferation by sirolimus-eluting stents: One-year angiographic and intravascular ultrasound follow-up
    • Sousa JE, Costa MA, Abizaid AC, Rensing BJ, Abizaid AS, Tanajura LF, et al. Sustained suppression of neointimal proliferation by sirolimus-eluting stents: one-year angiographic and intravascular ultrasound follow-up. Circulation 2001;104:2007-11.
    • (2001) Circulation , vol.104 , pp. 2007-2011
    • Sousa, J.E.1    Costa, M.A.2    Abizaid, A.C.3    Rensing, B.J.4    Abizaid, A.S.5    Tanajura, L.F.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.